Cargando…

Significant intra-valvular pressure loss across EPIC SUPRA and perimount magna supra-annular designed aortic bioprostheses in patients with normal aortic size

Doppler-derived trans-prosthetic gradients are higher and the estimated effective valve area is smaller than the catheter-derived and directly measured hemodynamic values, mostly due to pressure recovery phenomenon. Pressure recovery to a varying extent is common to all prosthetic heart valves inclu...

Descripción completa

Detalles Bibliográficos
Autores principales: Mohan, Jagdish C., Mohan, Vishwas, Shukla, Madhu, Sethi, Arvind
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5318985/
https://www.ncbi.nlm.nih.gov/pubmed/28228313
http://dx.doi.org/10.1016/j.ihj.2016.06.001
_version_ 1782509292073517056
author Mohan, Jagdish C.
Mohan, Vishwas
Shukla, Madhu
Sethi, Arvind
author_facet Mohan, Jagdish C.
Mohan, Vishwas
Shukla, Madhu
Sethi, Arvind
author_sort Mohan, Jagdish C.
collection PubMed
description Doppler-derived trans-prosthetic gradients are higher and the estimated effective valve area is smaller than the catheter-derived and directly measured hemodynamic values, mostly due to pressure recovery phenomenon. Pressure recovery to a varying extent is common to all prosthetic heart valves including bioprostheses. Pressure recovery-related differences are usually small except in patients with bileaflet metallic prosthesis, wherein high-pressure local jets across central orifice have been documented since long back and also in patients with narrow aortic root. We describe two patients with normally functioning stented aortic bioprostheses with supra-annular design (EPIC SUPRA and PERIMOUNT MAGNA), wherein very high trans-prosthetic gradients and critically reduced estimated effective valve orifice areas in presence of normal aortic size were consistently recorded over long periods of follow-up. The valve leaflets, however had normal excursion, were thin, opened with a triangular or oblong shape and had expected geometric valve area (1.7 and 1.6 cm(2) respectively) measured by 3D trans-oesophageal echocardiographic planimetry. Pressure recovery upstream the valves accounted for 20% and 12% of total pressure gradients respectively. Dominant site for pressure drop was intra-valvular (75–85%). Such a phenomenon has not been reported in vivo for these two valve designs.
format Online
Article
Text
id pubmed-5318985
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-53189852018-01-01 Significant intra-valvular pressure loss across EPIC SUPRA and perimount magna supra-annular designed aortic bioprostheses in patients with normal aortic size Mohan, Jagdish C. Mohan, Vishwas Shukla, Madhu Sethi, Arvind Indian Heart J Original Article Doppler-derived trans-prosthetic gradients are higher and the estimated effective valve area is smaller than the catheter-derived and directly measured hemodynamic values, mostly due to pressure recovery phenomenon. Pressure recovery to a varying extent is common to all prosthetic heart valves including bioprostheses. Pressure recovery-related differences are usually small except in patients with bileaflet metallic prosthesis, wherein high-pressure local jets across central orifice have been documented since long back and also in patients with narrow aortic root. We describe two patients with normally functioning stented aortic bioprostheses with supra-annular design (EPIC SUPRA and PERIMOUNT MAGNA), wherein very high trans-prosthetic gradients and critically reduced estimated effective valve orifice areas in presence of normal aortic size were consistently recorded over long periods of follow-up. The valve leaflets, however had normal excursion, were thin, opened with a triangular or oblong shape and had expected geometric valve area (1.7 and 1.6 cm(2) respectively) measured by 3D trans-oesophageal echocardiographic planimetry. Pressure recovery upstream the valves accounted for 20% and 12% of total pressure gradients respectively. Dominant site for pressure drop was intra-valvular (75–85%). Such a phenomenon has not been reported in vivo for these two valve designs. Elsevier 2017 2016-06-11 /pmc/articles/PMC5318985/ /pubmed/28228313 http://dx.doi.org/10.1016/j.ihj.2016.06.001 Text en © 2016 Published by Elsevier B.V. on behalf of Cardiological Society of India. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Mohan, Jagdish C.
Mohan, Vishwas
Shukla, Madhu
Sethi, Arvind
Significant intra-valvular pressure loss across EPIC SUPRA and perimount magna supra-annular designed aortic bioprostheses in patients with normal aortic size
title Significant intra-valvular pressure loss across EPIC SUPRA and perimount magna supra-annular designed aortic bioprostheses in patients with normal aortic size
title_full Significant intra-valvular pressure loss across EPIC SUPRA and perimount magna supra-annular designed aortic bioprostheses in patients with normal aortic size
title_fullStr Significant intra-valvular pressure loss across EPIC SUPRA and perimount magna supra-annular designed aortic bioprostheses in patients with normal aortic size
title_full_unstemmed Significant intra-valvular pressure loss across EPIC SUPRA and perimount magna supra-annular designed aortic bioprostheses in patients with normal aortic size
title_short Significant intra-valvular pressure loss across EPIC SUPRA and perimount magna supra-annular designed aortic bioprostheses in patients with normal aortic size
title_sort significant intra-valvular pressure loss across epic supra and perimount magna supra-annular designed aortic bioprostheses in patients with normal aortic size
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5318985/
https://www.ncbi.nlm.nih.gov/pubmed/28228313
http://dx.doi.org/10.1016/j.ihj.2016.06.001
work_keys_str_mv AT mohanjagdishc significantintravalvularpressurelossacrossepicsupraandperimountmagnasupraannulardesignedaorticbioprosthesesinpatientswithnormalaorticsize
AT mohanvishwas significantintravalvularpressurelossacrossepicsupraandperimountmagnasupraannulardesignedaorticbioprosthesesinpatientswithnormalaorticsize
AT shuklamadhu significantintravalvularpressurelossacrossepicsupraandperimountmagnasupraannulardesignedaorticbioprosthesesinpatientswithnormalaorticsize
AT sethiarvind significantintravalvularpressurelossacrossepicsupraandperimountmagnasupraannulardesignedaorticbioprosthesesinpatientswithnormalaorticsize