Assessment of axillary temperature for the evaluation of normal body temperature of healthy young adults at rest in a thermoneutral environment

BACKGROUND: The aims of this study were to (1) evaluate whether recently introduced methods of measuring axillary temperature are reliable, (2) examine if individuals know their baseline body temperature based on an actual measurement, and (3) assess the factors affecting axillary temperature and re...

Descripción completa

Detalles Bibliográficos
Autores principales: Marui, Shuri, Misawa, Ayaka, Tanaka, Yuki, Nagashima, Kei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5322586/
https://www.ncbi.nlm.nih.gov/pubmed/28228153
http://dx.doi.org/10.1186/s40101-017-0133-y
_version_ 1782509875402637312
author Marui, Shuri
Misawa, Ayaka
Tanaka, Yuki
Nagashima, Kei
author_facet Marui, Shuri
Misawa, Ayaka
Tanaka, Yuki
Nagashima, Kei
author_sort Marui, Shuri
collection PubMed
description BACKGROUND: The aims of this study were to (1) evaluate whether recently introduced methods of measuring axillary temperature are reliable, (2) examine if individuals know their baseline body temperature based on an actual measurement, and (3) assess the factors affecting axillary temperature and reevaluate the meaning of the axillary temperature. METHODS: Subjects were healthy young men and women (n = 76 and n = 65, respectively). Three measurements were obtained: (1) axillary temperature using a digital thermometer in a predictive mode requiring 10 s (T (ax-10 s)), (2) axillary temperature using a digital thermometer in a standard mode requiring 10 min (T (ax-10 min)), and (3) tympanic membrane temperature continuously measured by infrared thermometry (T (ty)). The subjects answered questions about eating and exercise habits, sleep and menstrual cycles, and thermoregulation and reported what they believed their regular body temperature to be (T (reg)). RESULTS: T (reg), T (ax-10 s), T (ax-10 min), and T (ty) were 36.2 ± 0.4, 36.4 ± 0.5, 36.5 ± 0.4, and 36.8 ± 0.3 °C (mean ± SD), respectively. There were correlations between T (ty) and T (ax-10 min), T (ty) and T (ax-10 s), and T (ax-10 min) and T (ax-10 s) (r = .62, r = .46, and r = .59, respectively, P < .001), but not between T (reg) and T (ax-10 s) (r = .11, P = .20). A lower T (ax-10 s) was associated with smaller body mass indices and irregular menstrual cycles. CONCLUSIONS: Modern devices for measuring axillary temperature may have changed the range of body temperature that is recognized as normal. Core body temperature variations estimated by tympanic measurements were smaller than those estimated by axillary measurements. This variation of axillary temperature may be due to changes in the measurement methods introduced by modern devices and techniques. However, axillary temperature values correlated well with those of tympanic measurements, suggesting that the technique may reliably report an individual’s state of health. It is important for individuals to know their baseline axillary temperature to evaluate subsequent temperature measurements as normal or abnormal. Moreover, axillary temperature variations may, in part, reflect fat mass and changes due to the menstrual cycle.
format Online
Article
Text
id pubmed-5322586
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-53225862017-03-01 Assessment of axillary temperature for the evaluation of normal body temperature of healthy young adults at rest in a thermoneutral environment Marui, Shuri Misawa, Ayaka Tanaka, Yuki Nagashima, Kei J Physiol Anthropol Original Article BACKGROUND: The aims of this study were to (1) evaluate whether recently introduced methods of measuring axillary temperature are reliable, (2) examine if individuals know their baseline body temperature based on an actual measurement, and (3) assess the factors affecting axillary temperature and reevaluate the meaning of the axillary temperature. METHODS: Subjects were healthy young men and women (n = 76 and n = 65, respectively). Three measurements were obtained: (1) axillary temperature using a digital thermometer in a predictive mode requiring 10 s (T (ax-10 s)), (2) axillary temperature using a digital thermometer in a standard mode requiring 10 min (T (ax-10 min)), and (3) tympanic membrane temperature continuously measured by infrared thermometry (T (ty)). The subjects answered questions about eating and exercise habits, sleep and menstrual cycles, and thermoregulation and reported what they believed their regular body temperature to be (T (reg)). RESULTS: T (reg), T (ax-10 s), T (ax-10 min), and T (ty) were 36.2 ± 0.4, 36.4 ± 0.5, 36.5 ± 0.4, and 36.8 ± 0.3 °C (mean ± SD), respectively. There were correlations between T (ty) and T (ax-10 min), T (ty) and T (ax-10 s), and T (ax-10 min) and T (ax-10 s) (r = .62, r = .46, and r = .59, respectively, P < .001), but not between T (reg) and T (ax-10 s) (r = .11, P = .20). A lower T (ax-10 s) was associated with smaller body mass indices and irregular menstrual cycles. CONCLUSIONS: Modern devices for measuring axillary temperature may have changed the range of body temperature that is recognized as normal. Core body temperature variations estimated by tympanic measurements were smaller than those estimated by axillary measurements. This variation of axillary temperature may be due to changes in the measurement methods introduced by modern devices and techniques. However, axillary temperature values correlated well with those of tympanic measurements, suggesting that the technique may reliably report an individual’s state of health. It is important for individuals to know their baseline axillary temperature to evaluate subsequent temperature measurements as normal or abnormal. Moreover, axillary temperature variations may, in part, reflect fat mass and changes due to the menstrual cycle. BioMed Central 2017-02-22 /pmc/articles/PMC5322586/ /pubmed/28228153 http://dx.doi.org/10.1186/s40101-017-0133-y Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Original Article
Marui, Shuri
Misawa, Ayaka
Tanaka, Yuki
Nagashima, Kei
Assessment of axillary temperature for the evaluation of normal body temperature of healthy young adults at rest in a thermoneutral environment
title Assessment of axillary temperature for the evaluation of normal body temperature of healthy young adults at rest in a thermoneutral environment
title_full Assessment of axillary temperature for the evaluation of normal body temperature of healthy young adults at rest in a thermoneutral environment
title_fullStr Assessment of axillary temperature for the evaluation of normal body temperature of healthy young adults at rest in a thermoneutral environment
title_full_unstemmed Assessment of axillary temperature for the evaluation of normal body temperature of healthy young adults at rest in a thermoneutral environment
title_short Assessment of axillary temperature for the evaluation of normal body temperature of healthy young adults at rest in a thermoneutral environment
title_sort assessment of axillary temperature for the evaluation of normal body temperature of healthy young adults at rest in a thermoneutral environment
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5322586/
https://www.ncbi.nlm.nih.gov/pubmed/28228153
http://dx.doi.org/10.1186/s40101-017-0133-y
work_keys_str_mv AT maruishuri assessmentofaxillarytemperaturefortheevaluationofnormalbodytemperatureofhealthyyoungadultsatrestinathermoneutralenvironment
AT misawaayaka assessmentofaxillarytemperaturefortheevaluationofnormalbodytemperatureofhealthyyoungadultsatrestinathermoneutralenvironment
AT tanakayuki assessmentofaxillarytemperaturefortheevaluationofnormalbodytemperatureofhealthyyoungadultsatrestinathermoneutralenvironment
AT nagashimakei assessmentofaxillarytemperaturefortheevaluationofnormalbodytemperatureofhealthyyoungadultsatrestinathermoneutralenvironment