Cargando…

Influence of hooks and a lag screw on internal fixation plates for lateral malleolar fracture: a biomechanical and ergonomic study

BACKGROUND: For internal fixation of AO classification Type B lateral malleolar fracture, insertion of lag screws into the fracture plane and fixation with a one-third tubular plate as a neutralization plate are the standard treatment procedures. The one-third tubular plate is processed to a hook sh...

Descripción completa

Detalles Bibliográficos
Autores principales: Sakai, Rina, Uchino, Masataka, Yoneo, Terumasa, Ohtaki, Yasuaki, Minehara, Hiroaki, Matsuura, Terumasa, Gomi, Tsutomu, Ujihira, Masanobu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5322609/
https://www.ncbi.nlm.nih.gov/pubmed/28228100
http://dx.doi.org/10.1186/s13018-017-0537-8
_version_ 1782509880644468736
author Sakai, Rina
Uchino, Masataka
Yoneo, Terumasa
Ohtaki, Yasuaki
Minehara, Hiroaki
Matsuura, Terumasa
Gomi, Tsutomu
Ujihira, Masanobu
author_facet Sakai, Rina
Uchino, Masataka
Yoneo, Terumasa
Ohtaki, Yasuaki
Minehara, Hiroaki
Matsuura, Terumasa
Gomi, Tsutomu
Ujihira, Masanobu
author_sort Sakai, Rina
collection PubMed
description BACKGROUND: For internal fixation of AO classification Type B lateral malleolar fracture, insertion of lag screws into the fracture plane and fixation with a one-third tubular plate as a neutralization plate are the standard treatment procedures. The one-third tubular plate is processed to a hook shape and hung on the distal end of the fibula. In this study, to compare the function of the hook and lag screws of a one-third tubular plate and LCP for osteosynthesis of lateral malleolar fracture, mechanical indices of internal fixation were compared among the one-third tubular plates with lag screws with and without the hook and a locking compression plate. METHODS: As mechanical tests, a compression test was performed in which compression in the bone axis direction produced by supporting the body weight was simulated, and a torsion test was performed in which external rotation of the bone axis caused by plantar flexion of the ankle joint was simulated. Muscle strength during walking and the force and torque acting on the ankle and knee joints were determined using inverse dynamic analysis. Finite element analysis was performed to analyze the function of hooks and lag screws. The joint reaction force determined by inverse dynamic analysis was adopted as the loading condition of finite element analysis. RESULTS: A stiffness equivalent to that of healthy bone could be achieved by all three internal fixations. It was clarified that the presence of the hook does not make a difference in stiffness. Displacement of the one-third tubular plate was small regardless of the presence or absence of the hook compared with those of locking compression plates. CONCLUSIONS: The presence of the hook did not make any difference in stiffness, suggesting that active preparation of the hook is unnecessary. We also clarified that lag screws inhibit displacement.
format Online
Article
Text
id pubmed-5322609
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-53226092017-03-01 Influence of hooks and a lag screw on internal fixation plates for lateral malleolar fracture: a biomechanical and ergonomic study Sakai, Rina Uchino, Masataka Yoneo, Terumasa Ohtaki, Yasuaki Minehara, Hiroaki Matsuura, Terumasa Gomi, Tsutomu Ujihira, Masanobu J Orthop Surg Res Research Article BACKGROUND: For internal fixation of AO classification Type B lateral malleolar fracture, insertion of lag screws into the fracture plane and fixation with a one-third tubular plate as a neutralization plate are the standard treatment procedures. The one-third tubular plate is processed to a hook shape and hung on the distal end of the fibula. In this study, to compare the function of the hook and lag screws of a one-third tubular plate and LCP for osteosynthesis of lateral malleolar fracture, mechanical indices of internal fixation were compared among the one-third tubular plates with lag screws with and without the hook and a locking compression plate. METHODS: As mechanical tests, a compression test was performed in which compression in the bone axis direction produced by supporting the body weight was simulated, and a torsion test was performed in which external rotation of the bone axis caused by plantar flexion of the ankle joint was simulated. Muscle strength during walking and the force and torque acting on the ankle and knee joints were determined using inverse dynamic analysis. Finite element analysis was performed to analyze the function of hooks and lag screws. The joint reaction force determined by inverse dynamic analysis was adopted as the loading condition of finite element analysis. RESULTS: A stiffness equivalent to that of healthy bone could be achieved by all three internal fixations. It was clarified that the presence of the hook does not make a difference in stiffness. Displacement of the one-third tubular plate was small regardless of the presence or absence of the hook compared with those of locking compression plates. CONCLUSIONS: The presence of the hook did not make any difference in stiffness, suggesting that active preparation of the hook is unnecessary. We also clarified that lag screws inhibit displacement. BioMed Central 2017-02-23 /pmc/articles/PMC5322609/ /pubmed/28228100 http://dx.doi.org/10.1186/s13018-017-0537-8 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Sakai, Rina
Uchino, Masataka
Yoneo, Terumasa
Ohtaki, Yasuaki
Minehara, Hiroaki
Matsuura, Terumasa
Gomi, Tsutomu
Ujihira, Masanobu
Influence of hooks and a lag screw on internal fixation plates for lateral malleolar fracture: a biomechanical and ergonomic study
title Influence of hooks and a lag screw on internal fixation plates for lateral malleolar fracture: a biomechanical and ergonomic study
title_full Influence of hooks and a lag screw on internal fixation plates for lateral malleolar fracture: a biomechanical and ergonomic study
title_fullStr Influence of hooks and a lag screw on internal fixation plates for lateral malleolar fracture: a biomechanical and ergonomic study
title_full_unstemmed Influence of hooks and a lag screw on internal fixation plates for lateral malleolar fracture: a biomechanical and ergonomic study
title_short Influence of hooks and a lag screw on internal fixation plates for lateral malleolar fracture: a biomechanical and ergonomic study
title_sort influence of hooks and a lag screw on internal fixation plates for lateral malleolar fracture: a biomechanical and ergonomic study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5322609/
https://www.ncbi.nlm.nih.gov/pubmed/28228100
http://dx.doi.org/10.1186/s13018-017-0537-8
work_keys_str_mv AT sakairina influenceofhooksandalagscrewoninternalfixationplatesforlateralmalleolarfractureabiomechanicalandergonomicstudy
AT uchinomasataka influenceofhooksandalagscrewoninternalfixationplatesforlateralmalleolarfractureabiomechanicalandergonomicstudy
AT yoneoterumasa influenceofhooksandalagscrewoninternalfixationplatesforlateralmalleolarfractureabiomechanicalandergonomicstudy
AT ohtakiyasuaki influenceofhooksandalagscrewoninternalfixationplatesforlateralmalleolarfractureabiomechanicalandergonomicstudy
AT mineharahiroaki influenceofhooksandalagscrewoninternalfixationplatesforlateralmalleolarfractureabiomechanicalandergonomicstudy
AT matsuuraterumasa influenceofhooksandalagscrewoninternalfixationplatesforlateralmalleolarfractureabiomechanicalandergonomicstudy
AT gomitsutomu influenceofhooksandalagscrewoninternalfixationplatesforlateralmalleolarfractureabiomechanicalandergonomicstudy
AT ujihiramasanobu influenceofhooksandalagscrewoninternalfixationplatesforlateralmalleolarfractureabiomechanicalandergonomicstudy