Cargando…

The 3-dimensional miniplate is more effective than the standard miniplate for the management of mandibular fractures: a meta-analysis

PURPOSE: The study aimed to determine the superiority between 3-dimensional (3D) miniplate and standard miniplate for mandibular fractures (MFs) treatment. BACKGROUND: Controversial results on the use of standard miniplate and 3D miniplate have remained for management of MFs. METHODS: Several electr...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Yong, Wei, Bo, Li, Yuxiang, Gu, Dawei, Yin, Guochao, Wang, Bo, Xu, Dehui, Zhang, Xuebing, Kong, Daliang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5322783/
https://www.ncbi.nlm.nih.gov/pubmed/28196543
http://dx.doi.org/10.1186/s40001-017-0244-2
_version_ 1782509915060830208
author Liu, Yong
Wei, Bo
Li, Yuxiang
Gu, Dawei
Yin, Guochao
Wang, Bo
Xu, Dehui
Zhang, Xuebing
Kong, Daliang
author_facet Liu, Yong
Wei, Bo
Li, Yuxiang
Gu, Dawei
Yin, Guochao
Wang, Bo
Xu, Dehui
Zhang, Xuebing
Kong, Daliang
author_sort Liu, Yong
collection PubMed
description PURPOSE: The study aimed to determine the superiority between 3-dimensional (3D) miniplate and standard miniplate for mandibular fractures (MFs) treatment. BACKGROUND: Controversial results on the use of standard miniplate and 3D miniplate have remained for management of MFs. METHODS: Several electronic databases were retrieved up to September 2014 to identify eligible studies. The quality of studies was assessed, and the relative risk (RR) with its corresponding 95% confidence interval (CI) was assessed to measure the effect size. Subgroup analyses by different fracture regions and different 3D miniplate sizes were performed. Publication bias was measured by a funnel plot. RESULTS: There were 13 studies included for the meta-analysis, consisting of 593 participants. The 3D miniplate achieved significant lower incidences of malocclusion (RR 0.43, 95% CI 0.24–0.77, P = 0.004) and hardware failure (RR 0.31, 95% CI 0.13–0.74, P = 0.008) than the standard miniplate. There were no significant differences between the two miniplates on the incidence of the remaining outcomes: wound dehiscence, infection, paresthesia, and nonunion/malunion. Subgroup analyses indicated that 3D miniplate caused a lower hardware failure than standard with the size of 8 or 10 holes (RR 0.23, 95% CI 0.08–0.66, P = 0.006). Besides, publication bias was not detected. CONCLUSION: The 3D miniplate is superior to the standard miniplate on the reduction of postoperative complication rates for the management of MFs. More holes in the 3D miniplate might contribute to a successful treatment.
format Online
Article
Text
id pubmed-5322783
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-53227832017-03-01 The 3-dimensional miniplate is more effective than the standard miniplate for the management of mandibular fractures: a meta-analysis Liu, Yong Wei, Bo Li, Yuxiang Gu, Dawei Yin, Guochao Wang, Bo Xu, Dehui Zhang, Xuebing Kong, Daliang Eur J Med Res Research PURPOSE: The study aimed to determine the superiority between 3-dimensional (3D) miniplate and standard miniplate for mandibular fractures (MFs) treatment. BACKGROUND: Controversial results on the use of standard miniplate and 3D miniplate have remained for management of MFs. METHODS: Several electronic databases were retrieved up to September 2014 to identify eligible studies. The quality of studies was assessed, and the relative risk (RR) with its corresponding 95% confidence interval (CI) was assessed to measure the effect size. Subgroup analyses by different fracture regions and different 3D miniplate sizes were performed. Publication bias was measured by a funnel plot. RESULTS: There were 13 studies included for the meta-analysis, consisting of 593 participants. The 3D miniplate achieved significant lower incidences of malocclusion (RR 0.43, 95% CI 0.24–0.77, P = 0.004) and hardware failure (RR 0.31, 95% CI 0.13–0.74, P = 0.008) than the standard miniplate. There were no significant differences between the two miniplates on the incidence of the remaining outcomes: wound dehiscence, infection, paresthesia, and nonunion/malunion. Subgroup analyses indicated that 3D miniplate caused a lower hardware failure than standard with the size of 8 or 10 holes (RR 0.23, 95% CI 0.08–0.66, P = 0.006). Besides, publication bias was not detected. CONCLUSION: The 3D miniplate is superior to the standard miniplate on the reduction of postoperative complication rates for the management of MFs. More holes in the 3D miniplate might contribute to a successful treatment. BioMed Central 2017-02-14 /pmc/articles/PMC5322783/ /pubmed/28196543 http://dx.doi.org/10.1186/s40001-017-0244-2 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Liu, Yong
Wei, Bo
Li, Yuxiang
Gu, Dawei
Yin, Guochao
Wang, Bo
Xu, Dehui
Zhang, Xuebing
Kong, Daliang
The 3-dimensional miniplate is more effective than the standard miniplate for the management of mandibular fractures: a meta-analysis
title The 3-dimensional miniplate is more effective than the standard miniplate for the management of mandibular fractures: a meta-analysis
title_full The 3-dimensional miniplate is more effective than the standard miniplate for the management of mandibular fractures: a meta-analysis
title_fullStr The 3-dimensional miniplate is more effective than the standard miniplate for the management of mandibular fractures: a meta-analysis
title_full_unstemmed The 3-dimensional miniplate is more effective than the standard miniplate for the management of mandibular fractures: a meta-analysis
title_short The 3-dimensional miniplate is more effective than the standard miniplate for the management of mandibular fractures: a meta-analysis
title_sort 3-dimensional miniplate is more effective than the standard miniplate for the management of mandibular fractures: a meta-analysis
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5322783/
https://www.ncbi.nlm.nih.gov/pubmed/28196543
http://dx.doi.org/10.1186/s40001-017-0244-2
work_keys_str_mv AT liuyong the3dimensionalminiplateismoreeffectivethanthestandardminiplateforthemanagementofmandibularfracturesametaanalysis
AT weibo the3dimensionalminiplateismoreeffectivethanthestandardminiplateforthemanagementofmandibularfracturesametaanalysis
AT liyuxiang the3dimensionalminiplateismoreeffectivethanthestandardminiplateforthemanagementofmandibularfracturesametaanalysis
AT gudawei the3dimensionalminiplateismoreeffectivethanthestandardminiplateforthemanagementofmandibularfracturesametaanalysis
AT yinguochao the3dimensionalminiplateismoreeffectivethanthestandardminiplateforthemanagementofmandibularfracturesametaanalysis
AT wangbo the3dimensionalminiplateismoreeffectivethanthestandardminiplateforthemanagementofmandibularfracturesametaanalysis
AT xudehui the3dimensionalminiplateismoreeffectivethanthestandardminiplateforthemanagementofmandibularfracturesametaanalysis
AT zhangxuebing the3dimensionalminiplateismoreeffectivethanthestandardminiplateforthemanagementofmandibularfracturesametaanalysis
AT kongdaliang the3dimensionalminiplateismoreeffectivethanthestandardminiplateforthemanagementofmandibularfracturesametaanalysis
AT liuyong 3dimensionalminiplateismoreeffectivethanthestandardminiplateforthemanagementofmandibularfracturesametaanalysis
AT weibo 3dimensionalminiplateismoreeffectivethanthestandardminiplateforthemanagementofmandibularfracturesametaanalysis
AT liyuxiang 3dimensionalminiplateismoreeffectivethanthestandardminiplateforthemanagementofmandibularfracturesametaanalysis
AT gudawei 3dimensionalminiplateismoreeffectivethanthestandardminiplateforthemanagementofmandibularfracturesametaanalysis
AT yinguochao 3dimensionalminiplateismoreeffectivethanthestandardminiplateforthemanagementofmandibularfracturesametaanalysis
AT wangbo 3dimensionalminiplateismoreeffectivethanthestandardminiplateforthemanagementofmandibularfracturesametaanalysis
AT xudehui 3dimensionalminiplateismoreeffectivethanthestandardminiplateforthemanagementofmandibularfracturesametaanalysis
AT zhangxuebing 3dimensionalminiplateismoreeffectivethanthestandardminiplateforthemanagementofmandibularfracturesametaanalysis
AT kongdaliang 3dimensionalminiplateismoreeffectivethanthestandardminiplateforthemanagementofmandibularfracturesametaanalysis