Cargando…
Ahmed glaucoma valve implant: surgical technique and complications
Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has enco...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5322839/ https://www.ncbi.nlm.nih.gov/pubmed/28255226 http://dx.doi.org/10.2147/OPTH.S104220 |
_version_ | 1782509922344239104 |
---|---|
author | Riva, Ivano Roberti, Gloria Oddone, Francesco Konstas, Anastasios GP Quaranta, Luciano |
author_facet | Riva, Ivano Roberti, Gloria Oddone, Francesco Konstas, Anastasios GP Quaranta, Luciano |
author_sort | Riva, Ivano |
collection | PubMed |
description | Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications. |
format | Online Article Text |
id | pubmed-5322839 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-53228392017-03-02 Ahmed glaucoma valve implant: surgical technique and complications Riva, Ivano Roberti, Gloria Oddone, Francesco Konstas, Anastasios GP Quaranta, Luciano Clin Ophthalmol Review Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications. Dove Medical Press 2017-02-17 /pmc/articles/PMC5322839/ /pubmed/28255226 http://dx.doi.org/10.2147/OPTH.S104220 Text en © 2017 Riva et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Review Riva, Ivano Roberti, Gloria Oddone, Francesco Konstas, Anastasios GP Quaranta, Luciano Ahmed glaucoma valve implant: surgical technique and complications |
title | Ahmed glaucoma valve implant: surgical technique and complications |
title_full | Ahmed glaucoma valve implant: surgical technique and complications |
title_fullStr | Ahmed glaucoma valve implant: surgical technique and complications |
title_full_unstemmed | Ahmed glaucoma valve implant: surgical technique and complications |
title_short | Ahmed glaucoma valve implant: surgical technique and complications |
title_sort | ahmed glaucoma valve implant: surgical technique and complications |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5322839/ https://www.ncbi.nlm.nih.gov/pubmed/28255226 http://dx.doi.org/10.2147/OPTH.S104220 |
work_keys_str_mv | AT rivaivano ahmedglaucomavalveimplantsurgicaltechniqueandcomplications AT robertigloria ahmedglaucomavalveimplantsurgicaltechniqueandcomplications AT oddonefrancesco ahmedglaucomavalveimplantsurgicaltechniqueandcomplications AT konstasanastasiosgp ahmedglaucomavalveimplantsurgicaltechniqueandcomplications AT quarantaluciano ahmedglaucomavalveimplantsurgicaltechniqueandcomplications |