Cargando…
Metered Cryospray™: a novel uniform, controlled, and consistent in vivo application of liquid nitrogen cryogenic spray
In this article, a novel cryotherapy approach using a uniform, controlled, and consistent in vivo application of liquid nitrogen (LN(2)) spray as a Metered Cryospray(™) (MCS) process is described. Although MCS may be used for many potential clinical applications, this paper focuses on the developmen...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Libertas Academica
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5322842/ https://www.ncbi.nlm.nih.gov/pubmed/28255257 http://dx.doi.org/10.2147/MDER.S124098 |
_version_ | 1782509923010084864 |
---|---|
author | Mulcahey, Thomas I Coad, James E Fan, Wei Li Grasso, Daniel J Hanley, Brian M Hawkes, Heather V McDermott, Sean A O’Connor, John P Sheets, Ellen E Vadala, Charles J |
author_facet | Mulcahey, Thomas I Coad, James E Fan, Wei Li Grasso, Daniel J Hanley, Brian M Hawkes, Heather V McDermott, Sean A O’Connor, John P Sheets, Ellen E Vadala, Charles J |
author_sort | Mulcahey, Thomas I |
collection | PubMed |
description | In this article, a novel cryotherapy approach using a uniform, controlled, and consistent in vivo application of liquid nitrogen (LN(2)) spray as a Metered Cryospray(™) (MCS) process is described. Although MCS may be used for many potential clinical applications, this paper focuses on the development that led to the controlled and consistent delivery of radial LN(2) cryogen spray in order to generate a uniform circumferential effect and how the amount of MCS can be adapted to specifically ablate targeted diseases within a patient’s lumen such as an airway or esophagus. |
format | Online Article Text |
id | pubmed-5322842 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Libertas Academica |
record_format | MEDLINE/PubMed |
spelling | pubmed-53228422017-03-02 Metered Cryospray™: a novel uniform, controlled, and consistent in vivo application of liquid nitrogen cryogenic spray Mulcahey, Thomas I Coad, James E Fan, Wei Li Grasso, Daniel J Hanley, Brian M Hawkes, Heather V McDermott, Sean A O’Connor, John P Sheets, Ellen E Vadala, Charles J Med Devices (Auckl) Original Research In this article, a novel cryotherapy approach using a uniform, controlled, and consistent in vivo application of liquid nitrogen (LN(2)) spray as a Metered Cryospray(™) (MCS) process is described. Although MCS may be used for many potential clinical applications, this paper focuses on the development that led to the controlled and consistent delivery of radial LN(2) cryogen spray in order to generate a uniform circumferential effect and how the amount of MCS can be adapted to specifically ablate targeted diseases within a patient’s lumen such as an airway or esophagus. Libertas Academica 2017-02-17 /pmc/articles/PMC5322842/ /pubmed/28255257 http://dx.doi.org/10.2147/MDER.S124098 Text en © 2017 Mulcahey et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed |
spellingShingle | Original Research Mulcahey, Thomas I Coad, James E Fan, Wei Li Grasso, Daniel J Hanley, Brian M Hawkes, Heather V McDermott, Sean A O’Connor, John P Sheets, Ellen E Vadala, Charles J Metered Cryospray™: a novel uniform, controlled, and consistent in vivo application of liquid nitrogen cryogenic spray |
title | Metered Cryospray™: a novel uniform, controlled, and consistent in vivo application of liquid nitrogen cryogenic spray |
title_full | Metered Cryospray™: a novel uniform, controlled, and consistent in vivo application of liquid nitrogen cryogenic spray |
title_fullStr | Metered Cryospray™: a novel uniform, controlled, and consistent in vivo application of liquid nitrogen cryogenic spray |
title_full_unstemmed | Metered Cryospray™: a novel uniform, controlled, and consistent in vivo application of liquid nitrogen cryogenic spray |
title_short | Metered Cryospray™: a novel uniform, controlled, and consistent in vivo application of liquid nitrogen cryogenic spray |
title_sort | metered cryospray™: a novel uniform, controlled, and consistent in vivo application of liquid nitrogen cryogenic spray |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5322842/ https://www.ncbi.nlm.nih.gov/pubmed/28255257 http://dx.doi.org/10.2147/MDER.S124098 |
work_keys_str_mv | AT mulcaheythomasi meteredcryosprayanoveluniformcontrolledandconsistentinvivoapplicationofliquidnitrogencryogenicspray AT coadjamese meteredcryosprayanoveluniformcontrolledandconsistentinvivoapplicationofliquidnitrogencryogenicspray AT fanweili meteredcryosprayanoveluniformcontrolledandconsistentinvivoapplicationofliquidnitrogencryogenicspray AT grassodanielj meteredcryosprayanoveluniformcontrolledandconsistentinvivoapplicationofliquidnitrogencryogenicspray AT hanleybrianm meteredcryosprayanoveluniformcontrolledandconsistentinvivoapplicationofliquidnitrogencryogenicspray AT hawkesheatherv meteredcryosprayanoveluniformcontrolledandconsistentinvivoapplicationofliquidnitrogencryogenicspray AT mcdermottseana meteredcryosprayanoveluniformcontrolledandconsistentinvivoapplicationofliquidnitrogencryogenicspray AT oconnorjohnp meteredcryosprayanoveluniformcontrolledandconsistentinvivoapplicationofliquidnitrogencryogenicspray AT sheetsellene meteredcryosprayanoveluniformcontrolledandconsistentinvivoapplicationofliquidnitrogencryogenicspray AT vadalacharlesj meteredcryosprayanoveluniformcontrolledandconsistentinvivoapplicationofliquidnitrogencryogenicspray |