Cargando…

Diagnosis of insulin autoimmune syndrome using polyethylene glycol precipitation and gel filtration chromatography with ex vivo insulin exchange

CONTEXT: Insulin‐binding antibodies may produce severe dysglycaemia in insulin‐naïve patients (‘insulin autoimmune syndrome’ (IAS) or Hirata disease), while rendering routine insulin assays unreliable. OBJECTIVE: To assess the performance of clinically used insulin assays and an optimal analytical a...

Descripción completa

Detalles Bibliográficos
Autores principales: Church, David, Cardoso, Luís, Bradbury, Sonia, Clarke, Catriona, Stears, Anna, Dover, Anna, Halsall, David, Semple, Robert
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5324546/
https://www.ncbi.nlm.nih.gov/pubmed/27588366
http://dx.doi.org/10.1111/cen.13179
_version_ 1782510224247095296
author Church, David
Cardoso, Luís
Bradbury, Sonia
Clarke, Catriona
Stears, Anna
Dover, Anna
Halsall, David
Semple, Robert
author_facet Church, David
Cardoso, Luís
Bradbury, Sonia
Clarke, Catriona
Stears, Anna
Dover, Anna
Halsall, David
Semple, Robert
author_sort Church, David
collection PubMed
description CONTEXT: Insulin‐binding antibodies may produce severe dysglycaemia in insulin‐naïve patients (‘insulin autoimmune syndrome’ (IAS) or Hirata disease), while rendering routine insulin assays unreliable. OBJECTIVE: To assess the performance of clinically used insulin assays and an optimal analytical approach in the context of IAS. DESIGN: Observational biochemical study of selected patients with hyperinsulinaemic hypoglycaemia. PATIENTS: Three patients without diabetes with recurrent spontaneous hyperinsulinaemic hypoglycaemia and ‘positive’ insulin antibodies. MEASUREMENTS: A panel of clinically used insulin assays (Siemens ADVIA (®) Centaur, Siemens Immulite(®) 2000, DiaSorin LIAISON (®) XL, PE AutoDELFIA (®) and the Beckman Coulter Access(®) 2) were used before and after plasma dilution or polyethylene glycol (PEG) precipitation. Anti‐insulin IgG antibodies were measured by Isletest(™)‐IAA ELISA. Gel filtration chromatography (GFC) was undertaken with and without preincubation of plasma with exogenous insulin. RESULTS: Dilution of IAS plasma with assay‐specific buffer increased insulin recovery, supporting negative immunoassay interference by antibodies. PEG precipitation of IAS plasma decreased insulin recovery using all assays except the Immulite(®) 2000. GFC discriminated high molecular weight and monomeric insulin, while ex vivo addition of exogenous insulin to plasma increased insulin bound to antibody, thereby improving the sensitivity of detection of insulin immunocomplexes. CONCLUSIONS: Immunoprecipitation with PEG must be used with caution in screening for insulin–antibody complexes as results are assay dependent. GFC with addition of exogenous insulin can identify significant insulin immunocomplexes with enhanced sensitivity, with attendant greater clinical utility and avoidance of radiolabelled reagents.
format Online
Article
Text
id pubmed-5324546
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-53245462017-03-08 Diagnosis of insulin autoimmune syndrome using polyethylene glycol precipitation and gel filtration chromatography with ex vivo insulin exchange Church, David Cardoso, Luís Bradbury, Sonia Clarke, Catriona Stears, Anna Dover, Anna Halsall, David Semple, Robert Clin Endocrinol (Oxf) Original Articles CONTEXT: Insulin‐binding antibodies may produce severe dysglycaemia in insulin‐naïve patients (‘insulin autoimmune syndrome’ (IAS) or Hirata disease), while rendering routine insulin assays unreliable. OBJECTIVE: To assess the performance of clinically used insulin assays and an optimal analytical approach in the context of IAS. DESIGN: Observational biochemical study of selected patients with hyperinsulinaemic hypoglycaemia. PATIENTS: Three patients without diabetes with recurrent spontaneous hyperinsulinaemic hypoglycaemia and ‘positive’ insulin antibodies. MEASUREMENTS: A panel of clinically used insulin assays (Siemens ADVIA (®) Centaur, Siemens Immulite(®) 2000, DiaSorin LIAISON (®) XL, PE AutoDELFIA (®) and the Beckman Coulter Access(®) 2) were used before and after plasma dilution or polyethylene glycol (PEG) precipitation. Anti‐insulin IgG antibodies were measured by Isletest(™)‐IAA ELISA. Gel filtration chromatography (GFC) was undertaken with and without preincubation of plasma with exogenous insulin. RESULTS: Dilution of IAS plasma with assay‐specific buffer increased insulin recovery, supporting negative immunoassay interference by antibodies. PEG precipitation of IAS plasma decreased insulin recovery using all assays except the Immulite(®) 2000. GFC discriminated high molecular weight and monomeric insulin, while ex vivo addition of exogenous insulin to plasma increased insulin bound to antibody, thereby improving the sensitivity of detection of insulin immunocomplexes. CONCLUSIONS: Immunoprecipitation with PEG must be used with caution in screening for insulin–antibody complexes as results are assay dependent. GFC with addition of exogenous insulin can identify significant insulin immunocomplexes with enhanced sensitivity, with attendant greater clinical utility and avoidance of radiolabelled reagents. John Wiley and Sons Inc. 2016-10-03 2017-03 /pmc/articles/PMC5324546/ /pubmed/27588366 http://dx.doi.org/10.1111/cen.13179 Text en © 2016 The Authors. Clinical Endocrinology Published by John Wiley & Sons Ltd. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Church, David
Cardoso, Luís
Bradbury, Sonia
Clarke, Catriona
Stears, Anna
Dover, Anna
Halsall, David
Semple, Robert
Diagnosis of insulin autoimmune syndrome using polyethylene glycol precipitation and gel filtration chromatography with ex vivo insulin exchange
title Diagnosis of insulin autoimmune syndrome using polyethylene glycol precipitation and gel filtration chromatography with ex vivo insulin exchange
title_full Diagnosis of insulin autoimmune syndrome using polyethylene glycol precipitation and gel filtration chromatography with ex vivo insulin exchange
title_fullStr Diagnosis of insulin autoimmune syndrome using polyethylene glycol precipitation and gel filtration chromatography with ex vivo insulin exchange
title_full_unstemmed Diagnosis of insulin autoimmune syndrome using polyethylene glycol precipitation and gel filtration chromatography with ex vivo insulin exchange
title_short Diagnosis of insulin autoimmune syndrome using polyethylene glycol precipitation and gel filtration chromatography with ex vivo insulin exchange
title_sort diagnosis of insulin autoimmune syndrome using polyethylene glycol precipitation and gel filtration chromatography with ex vivo insulin exchange
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5324546/
https://www.ncbi.nlm.nih.gov/pubmed/27588366
http://dx.doi.org/10.1111/cen.13179
work_keys_str_mv AT churchdavid diagnosisofinsulinautoimmunesyndromeusingpolyethyleneglycolprecipitationandgelfiltrationchromatographywithexvivoinsulinexchange
AT cardosoluis diagnosisofinsulinautoimmunesyndromeusingpolyethyleneglycolprecipitationandgelfiltrationchromatographywithexvivoinsulinexchange
AT bradburysonia diagnosisofinsulinautoimmunesyndromeusingpolyethyleneglycolprecipitationandgelfiltrationchromatographywithexvivoinsulinexchange
AT clarkecatriona diagnosisofinsulinautoimmunesyndromeusingpolyethyleneglycolprecipitationandgelfiltrationchromatographywithexvivoinsulinexchange
AT stearsanna diagnosisofinsulinautoimmunesyndromeusingpolyethyleneglycolprecipitationandgelfiltrationchromatographywithexvivoinsulinexchange
AT doveranna diagnosisofinsulinautoimmunesyndromeusingpolyethyleneglycolprecipitationandgelfiltrationchromatographywithexvivoinsulinexchange
AT halsalldavid diagnosisofinsulinautoimmunesyndromeusingpolyethyleneglycolprecipitationandgelfiltrationchromatographywithexvivoinsulinexchange
AT semplerobert diagnosisofinsulinautoimmunesyndromeusingpolyethyleneglycolprecipitationandgelfiltrationchromatographywithexvivoinsulinexchange