Cargando…
Effects of postural change on transesophageal echocardiography views and parameters in healthy dogs
The purpose of the present study is to investigate the effect of postural change on transesophageal echocardiography (TEE) views and parameters of interest anesthesia monitoring in healthy dogs. Twelve Beagle dogs were anesthetized and randomly positioned in one of four postures: right lateral-recum...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japanese Society of Veterinary Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5326945/ https://www.ncbi.nlm.nih.gov/pubmed/27980234 http://dx.doi.org/10.1292/jvms.16-0323 |
_version_ | 1782510632952659968 |
---|---|
author | GOYA, Seijirow WADA, Tomoki SHIMADA, Kazumi HIRAO, Daiki FUKUSHIMA, Ryuji YAMAGISHI, Norio SHIMIZU, Miki TANAKA, Ryou |
author_facet | GOYA, Seijirow WADA, Tomoki SHIMADA, Kazumi HIRAO, Daiki FUKUSHIMA, Ryuji YAMAGISHI, Norio SHIMIZU, Miki TANAKA, Ryou |
author_sort | GOYA, Seijirow |
collection | PubMed |
description | The purpose of the present study is to investigate the effect of postural change on transesophageal echocardiography (TEE) views and parameters of interest anesthesia monitoring in healthy dogs. Twelve Beagle dogs were anesthetized and randomly positioned in one of four postures: right lateral-recumbency, left lateral-recumbency, supine position and prone position. After examinations in one posture, the same examination was demonstrated in another posture and repeated in all postures. In each posture, several standard TEE views were demonstrated: longitudinal cranial-esophageal aorta long-axis-view, transverse middle-esophageal mitral valve long-axis-view and transgastric middle short-axis-view. Additionally, echocardiographic parameters were attempted to measure, and direct blood pressure monitoring was performed in each view. As a result, oriented views, except for transgastric middle short-axis-view, could be obtained in all postures. Stroke volume and peak early diastolic velocity of mitral inflow were lower in supine position compared with those in right and left lateral-recumbency. Heart rate (HR) and systemic vascular resistance were higher in supine position compared with those in right and left lateral-recumbency. Left ventricular pre-ejection period/left ventricular ejection time corrected and uncorrected by HR were higher in supine position compared with those in right and left lateral-recumbency. In conclusion, longitudinal cranial-esophageal aorta long-axis-view and transverse middle-esophageal mitral valve long-axis-view provide useful information of interest anesthesia monitoring, because of their views enable to certainly obtain TEE parameters in various postures. Furthermore, TEE parameters allow to detect the changes of preload, afterload and HR that occur in supine position dogs. |
format | Online Article Text |
id | pubmed-5326945 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | The Japanese Society of Veterinary Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-53269452017-03-06 Effects of postural change on transesophageal echocardiography views and parameters in healthy dogs GOYA, Seijirow WADA, Tomoki SHIMADA, Kazumi HIRAO, Daiki FUKUSHIMA, Ryuji YAMAGISHI, Norio SHIMIZU, Miki TANAKA, Ryou J Vet Med Sci Internal Medicine The purpose of the present study is to investigate the effect of postural change on transesophageal echocardiography (TEE) views and parameters of interest anesthesia monitoring in healthy dogs. Twelve Beagle dogs were anesthetized and randomly positioned in one of four postures: right lateral-recumbency, left lateral-recumbency, supine position and prone position. After examinations in one posture, the same examination was demonstrated in another posture and repeated in all postures. In each posture, several standard TEE views were demonstrated: longitudinal cranial-esophageal aorta long-axis-view, transverse middle-esophageal mitral valve long-axis-view and transgastric middle short-axis-view. Additionally, echocardiographic parameters were attempted to measure, and direct blood pressure monitoring was performed in each view. As a result, oriented views, except for transgastric middle short-axis-view, could be obtained in all postures. Stroke volume and peak early diastolic velocity of mitral inflow were lower in supine position compared with those in right and left lateral-recumbency. Heart rate (HR) and systemic vascular resistance were higher in supine position compared with those in right and left lateral-recumbency. Left ventricular pre-ejection period/left ventricular ejection time corrected and uncorrected by HR were higher in supine position compared with those in right and left lateral-recumbency. In conclusion, longitudinal cranial-esophageal aorta long-axis-view and transverse middle-esophageal mitral valve long-axis-view provide useful information of interest anesthesia monitoring, because of their views enable to certainly obtain TEE parameters in various postures. Furthermore, TEE parameters allow to detect the changes of preload, afterload and HR that occur in supine position dogs. The Japanese Society of Veterinary Science 2016-12-16 2017-02 /pmc/articles/PMC5326945/ /pubmed/27980234 http://dx.doi.org/10.1292/jvms.16-0323 Text en ©2017 The Japanese Society of Veterinary Science This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License. (CC-BY-NC-ND 4.0: http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Internal Medicine GOYA, Seijirow WADA, Tomoki SHIMADA, Kazumi HIRAO, Daiki FUKUSHIMA, Ryuji YAMAGISHI, Norio SHIMIZU, Miki TANAKA, Ryou Effects of postural change on transesophageal echocardiography views and parameters in healthy dogs |
title | Effects of postural change on transesophageal echocardiography views and
parameters in healthy dogs |
title_full | Effects of postural change on transesophageal echocardiography views and
parameters in healthy dogs |
title_fullStr | Effects of postural change on transesophageal echocardiography views and
parameters in healthy dogs |
title_full_unstemmed | Effects of postural change on transesophageal echocardiography views and
parameters in healthy dogs |
title_short | Effects of postural change on transesophageal echocardiography views and
parameters in healthy dogs |
title_sort | effects of postural change on transesophageal echocardiography views and
parameters in healthy dogs |
topic | Internal Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5326945/ https://www.ncbi.nlm.nih.gov/pubmed/27980234 http://dx.doi.org/10.1292/jvms.16-0323 |
work_keys_str_mv | AT goyaseijirow effectsofposturalchangeontransesophagealechocardiographyviewsandparametersinhealthydogs AT wadatomoki effectsofposturalchangeontransesophagealechocardiographyviewsandparametersinhealthydogs AT shimadakazumi effectsofposturalchangeontransesophagealechocardiographyviewsandparametersinhealthydogs AT hiraodaiki effectsofposturalchangeontransesophagealechocardiographyviewsandparametersinhealthydogs AT fukushimaryuji effectsofposturalchangeontransesophagealechocardiographyviewsandparametersinhealthydogs AT yamagishinorio effectsofposturalchangeontransesophagealechocardiographyviewsandparametersinhealthydogs AT shimizumiki effectsofposturalchangeontransesophagealechocardiographyviewsandparametersinhealthydogs AT tanakaryou effectsofposturalchangeontransesophagealechocardiographyviewsandparametersinhealthydogs |