Cargando…

Effects of postural change on transesophageal echocardiography views and parameters in healthy dogs

The purpose of the present study is to investigate the effect of postural change on transesophageal echocardiography (TEE) views and parameters of interest anesthesia monitoring in healthy dogs. Twelve Beagle dogs were anesthetized and randomly positioned in one of four postures: right lateral-recum...

Descripción completa

Detalles Bibliográficos
Autores principales: GOYA, Seijirow, WADA, Tomoki, SHIMADA, Kazumi, HIRAO, Daiki, FUKUSHIMA, Ryuji, YAMAGISHI, Norio, SHIMIZU, Miki, TANAKA, Ryou
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japanese Society of Veterinary Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5326945/
https://www.ncbi.nlm.nih.gov/pubmed/27980234
http://dx.doi.org/10.1292/jvms.16-0323
_version_ 1782510632952659968
author GOYA, Seijirow
WADA, Tomoki
SHIMADA, Kazumi
HIRAO, Daiki
FUKUSHIMA, Ryuji
YAMAGISHI, Norio
SHIMIZU, Miki
TANAKA, Ryou
author_facet GOYA, Seijirow
WADA, Tomoki
SHIMADA, Kazumi
HIRAO, Daiki
FUKUSHIMA, Ryuji
YAMAGISHI, Norio
SHIMIZU, Miki
TANAKA, Ryou
author_sort GOYA, Seijirow
collection PubMed
description The purpose of the present study is to investigate the effect of postural change on transesophageal echocardiography (TEE) views and parameters of interest anesthesia monitoring in healthy dogs. Twelve Beagle dogs were anesthetized and randomly positioned in one of four postures: right lateral-recumbency, left lateral-recumbency, supine position and prone position. After examinations in one posture, the same examination was demonstrated in another posture and repeated in all postures. In each posture, several standard TEE views were demonstrated: longitudinal cranial-esophageal aorta long-axis-view, transverse middle-esophageal mitral valve long-axis-view and transgastric middle short-axis-view. Additionally, echocardiographic parameters were attempted to measure, and direct blood pressure monitoring was performed in each view. As a result, oriented views, except for transgastric middle short-axis-view, could be obtained in all postures. Stroke volume and peak early diastolic velocity of mitral inflow were lower in supine position compared with those in right and left lateral-recumbency. Heart rate (HR) and systemic vascular resistance were higher in supine position compared with those in right and left lateral-recumbency. Left ventricular pre-ejection period/left ventricular ejection time corrected and uncorrected by HR were higher in supine position compared with those in right and left lateral-recumbency. In conclusion, longitudinal cranial-esophageal aorta long-axis-view and transverse middle-esophageal mitral valve long-axis-view provide useful information of interest anesthesia monitoring, because of their views enable to certainly obtain TEE parameters in various postures. Furthermore, TEE parameters allow to detect the changes of preload, afterload and HR that occur in supine position dogs.
format Online
Article
Text
id pubmed-5326945
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Japanese Society of Veterinary Science
record_format MEDLINE/PubMed
spelling pubmed-53269452017-03-06 Effects of postural change on transesophageal echocardiography views and parameters in healthy dogs GOYA, Seijirow WADA, Tomoki SHIMADA, Kazumi HIRAO, Daiki FUKUSHIMA, Ryuji YAMAGISHI, Norio SHIMIZU, Miki TANAKA, Ryou J Vet Med Sci Internal Medicine The purpose of the present study is to investigate the effect of postural change on transesophageal echocardiography (TEE) views and parameters of interest anesthesia monitoring in healthy dogs. Twelve Beagle dogs were anesthetized and randomly positioned in one of four postures: right lateral-recumbency, left lateral-recumbency, supine position and prone position. After examinations in one posture, the same examination was demonstrated in another posture and repeated in all postures. In each posture, several standard TEE views were demonstrated: longitudinal cranial-esophageal aorta long-axis-view, transverse middle-esophageal mitral valve long-axis-view and transgastric middle short-axis-view. Additionally, echocardiographic parameters were attempted to measure, and direct blood pressure monitoring was performed in each view. As a result, oriented views, except for transgastric middle short-axis-view, could be obtained in all postures. Stroke volume and peak early diastolic velocity of mitral inflow were lower in supine position compared with those in right and left lateral-recumbency. Heart rate (HR) and systemic vascular resistance were higher in supine position compared with those in right and left lateral-recumbency. Left ventricular pre-ejection period/left ventricular ejection time corrected and uncorrected by HR were higher in supine position compared with those in right and left lateral-recumbency. In conclusion, longitudinal cranial-esophageal aorta long-axis-view and transverse middle-esophageal mitral valve long-axis-view provide useful information of interest anesthesia monitoring, because of their views enable to certainly obtain TEE parameters in various postures. Furthermore, TEE parameters allow to detect the changes of preload, afterload and HR that occur in supine position dogs. The Japanese Society of Veterinary Science 2016-12-16 2017-02 /pmc/articles/PMC5326945/ /pubmed/27980234 http://dx.doi.org/10.1292/jvms.16-0323 Text en ©2017 The Japanese Society of Veterinary Science This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License. (CC-BY-NC-ND 4.0: http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Internal Medicine
GOYA, Seijirow
WADA, Tomoki
SHIMADA, Kazumi
HIRAO, Daiki
FUKUSHIMA, Ryuji
YAMAGISHI, Norio
SHIMIZU, Miki
TANAKA, Ryou
Effects of postural change on transesophageal echocardiography views and parameters in healthy dogs
title Effects of postural change on transesophageal echocardiography views and parameters in healthy dogs
title_full Effects of postural change on transesophageal echocardiography views and parameters in healthy dogs
title_fullStr Effects of postural change on transesophageal echocardiography views and parameters in healthy dogs
title_full_unstemmed Effects of postural change on transesophageal echocardiography views and parameters in healthy dogs
title_short Effects of postural change on transesophageal echocardiography views and parameters in healthy dogs
title_sort effects of postural change on transesophageal echocardiography views and parameters in healthy dogs
topic Internal Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5326945/
https://www.ncbi.nlm.nih.gov/pubmed/27980234
http://dx.doi.org/10.1292/jvms.16-0323
work_keys_str_mv AT goyaseijirow effectsofposturalchangeontransesophagealechocardiographyviewsandparametersinhealthydogs
AT wadatomoki effectsofposturalchangeontransesophagealechocardiographyviewsandparametersinhealthydogs
AT shimadakazumi effectsofposturalchangeontransesophagealechocardiographyviewsandparametersinhealthydogs
AT hiraodaiki effectsofposturalchangeontransesophagealechocardiographyviewsandparametersinhealthydogs
AT fukushimaryuji effectsofposturalchangeontransesophagealechocardiographyviewsandparametersinhealthydogs
AT yamagishinorio effectsofposturalchangeontransesophagealechocardiographyviewsandparametersinhealthydogs
AT shimizumiki effectsofposturalchangeontransesophagealechocardiographyviewsandparametersinhealthydogs
AT tanakaryou effectsofposturalchangeontransesophagealechocardiographyviewsandparametersinhealthydogs