Cargando…

Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design

PURPOSE: To compare the anterior capsule contraction and intraocular lens (IOL) decentration among three types of IOL to determine the influence of haptic design on anterior capsule stability. METHODS: One hundred fifty patients were enrolled in this prospective, randomized study and 260 eyes underw...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Soonwon, Lim, Sung A, Na, Kyung-Sun, Joo, Choun-Ki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Ophthalmological Society 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5327172/
https://www.ncbi.nlm.nih.gov/pubmed/28243021
http://dx.doi.org/10.3341/kjo.2017.31.1.32
_version_ 1782510675086540800
author Yang, Soonwon
Lim, Sung A
Na, Kyung-Sun
Joo, Choun-Ki
author_facet Yang, Soonwon
Lim, Sung A
Na, Kyung-Sun
Joo, Choun-Ki
author_sort Yang, Soonwon
collection PubMed
description PURPOSE: To compare the anterior capsule contraction and intraocular lens (IOL) decentration among three types of IOL to determine the influence of haptic design on anterior capsule stability. METHODS: One hundred fifty patients were enrolled in this prospective, randomized study and 260 eyes underwent implantation of one of the following IOLs: modified L-haptic IOL (n = 74), modified C-haptic IOL (n = 97), or a plate-haptic IOL (n = 89). The area of the anterior capsule opening, IOL decentration, and capsule overlap were measured using retroillumination photospot 1 day and 2 months after cataract surgery. RESULTS: The area of capsule opening at postoperative day 1 was significantly different between the three IOLs (p < 0.01). All IOLs showed reduction of the anterior capsule opening from 1 day to 2 months after surgery, and greater reduction was shown in the modified C-haptic IOL (p < 0.001). At postoperative month 2, IOL decentration was significantly different between the IOLs and showed a positive correlation with the mean area reduction during month 2. CONCLUSIONS: The degree of anterior capsule contraction and IOL decentration in modified L-haptic IOLs were less than those in modified C-haptic IOLs and comparable to those in plate-haptic IOLs.
format Online
Article
Text
id pubmed-5327172
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher The Korean Ophthalmological Society
record_format MEDLINE/PubMed
spelling pubmed-53271722017-02-27 Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design Yang, Soonwon Lim, Sung A Na, Kyung-Sun Joo, Choun-Ki Korean J Ophthalmol Original Article PURPOSE: To compare the anterior capsule contraction and intraocular lens (IOL) decentration among three types of IOL to determine the influence of haptic design on anterior capsule stability. METHODS: One hundred fifty patients were enrolled in this prospective, randomized study and 260 eyes underwent implantation of one of the following IOLs: modified L-haptic IOL (n = 74), modified C-haptic IOL (n = 97), or a plate-haptic IOL (n = 89). The area of the anterior capsule opening, IOL decentration, and capsule overlap were measured using retroillumination photospot 1 day and 2 months after cataract surgery. RESULTS: The area of capsule opening at postoperative day 1 was significantly different between the three IOLs (p < 0.01). All IOLs showed reduction of the anterior capsule opening from 1 day to 2 months after surgery, and greater reduction was shown in the modified C-haptic IOL (p < 0.001). At postoperative month 2, IOL decentration was significantly different between the IOLs and showed a positive correlation with the mean area reduction during month 2. CONCLUSIONS: The degree of anterior capsule contraction and IOL decentration in modified L-haptic IOLs were less than those in modified C-haptic IOLs and comparable to those in plate-haptic IOLs. The Korean Ophthalmological Society 2017-02 2017-02-02 /pmc/articles/PMC5327172/ /pubmed/28243021 http://dx.doi.org/10.3341/kjo.2017.31.1.32 Text en © 2017 The Korean Ophthalmological Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yang, Soonwon
Lim, Sung A
Na, Kyung-Sun
Joo, Choun-Ki
Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design
title Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design
title_full Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design
title_fullStr Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design
title_full_unstemmed Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design
title_short Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design
title_sort comparison of anterior capsule stability following implantation of three single piece acrylic intraocular lenses with different haptic design
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5327172/
https://www.ncbi.nlm.nih.gov/pubmed/28243021
http://dx.doi.org/10.3341/kjo.2017.31.1.32
work_keys_str_mv AT yangsoonwon comparisonofanteriorcapsulestabilityfollowingimplantationofthreesinglepieceacrylicintraocularlenseswithdifferenthapticdesign
AT limsunga comparisonofanteriorcapsulestabilityfollowingimplantationofthreesinglepieceacrylicintraocularlenseswithdifferenthapticdesign
AT nakyungsun comparisonofanteriorcapsulestabilityfollowingimplantationofthreesinglepieceacrylicintraocularlenseswithdifferenthapticdesign
AT joochounki comparisonofanteriorcapsulestabilityfollowingimplantationofthreesinglepieceacrylicintraocularlenseswithdifferenthapticdesign