Cargando…

Indications of implant removal: A study of 83 cases

INTRODUCTION: Fracture fixation has become advanced with the advent of new and custom metal implants for each type of bone/fracture. After union though, the implant ceases to be important and may be removed. Routine removal is advocated by some and opposed by others. Nevertheless, some patients requ...

Descripción completa

Detalles Bibliográficos
Autores principales: Haseeb, Muhammad, Butt, Muhammad Farooq, Altaf, Tariq, Muzaffar, Khalid, Gupta, Anil, Jallu, Aleena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Qassim Uninversity 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5327671/
https://www.ncbi.nlm.nih.gov/pubmed/28293156
_version_ 1782510782857084928
author Haseeb, Muhammad
Butt, Muhammad Farooq
Altaf, Tariq
Muzaffar, Khalid
Gupta, Anil
Jallu, Aleena
author_facet Haseeb, Muhammad
Butt, Muhammad Farooq
Altaf, Tariq
Muzaffar, Khalid
Gupta, Anil
Jallu, Aleena
author_sort Haseeb, Muhammad
collection PubMed
description INTRODUCTION: Fracture fixation has become advanced with the advent of new and custom metal implants for each type of bone/fracture. After union though, the implant ceases to be important and may be removed. Routine removal is advocated by some and opposed by others. Nevertheless, some patients require removal of the hardware because of various implant-related problems. Our study was aimed at identifying the most common causes for implant removal. OBJECTIVE: To investigate the common indications of orthopedic implant removal surgeries. METHODS: Adult patients admitted for implant removal in our department were included in the study. They were operated in the next OT list. They were then followed for an average 4 months for resolutions of symptoms or appearance of new problems. RESULTS: A total of 83 patients were studied. 71 of them were males. The mean age was 38 years. The reasons for removal of implants were found to lie in five categories: Pain/discomfort/prominent hardware, infected hardware, implant failure, elective (patient’s insistence), and other reasons. Overall, the most frequently removed implants in our series were distal tibial/ankle plates (14.45% of implants removed), femoral intramedullary (IM) nails (13.25%), olecranon wires and plates (12.04%), and tibial IM nails and patellar tension band wirings (9.53% each). DISCUSSION AND CONCLUSION: The clinical indications of implant removal are not well established, and few definitive data exist to guide whether routine implant removal is appropriate. Symptomatic hardware frequently needs removal. We found that pain and implant prominence (mechanical symptoms) are the most common indications. Infection is the next most common, followed by hardware failure. Other indications are implant failure, bone resorption due to excessive stress shielding and patient’s will. Removal is, however, not an easy surgery, and several factors such as bone ingrowth and wear of the implant may make its removal difficult.
format Online
Article
Text
id pubmed-5327671
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Qassim Uninversity
record_format MEDLINE/PubMed
spelling pubmed-53276712017-03-14 Indications of implant removal: A study of 83 cases Haseeb, Muhammad Butt, Muhammad Farooq Altaf, Tariq Muzaffar, Khalid Gupta, Anil Jallu, Aleena Int J Health Sci (Qassim) Original Article INTRODUCTION: Fracture fixation has become advanced with the advent of new and custom metal implants for each type of bone/fracture. After union though, the implant ceases to be important and may be removed. Routine removal is advocated by some and opposed by others. Nevertheless, some patients require removal of the hardware because of various implant-related problems. Our study was aimed at identifying the most common causes for implant removal. OBJECTIVE: To investigate the common indications of orthopedic implant removal surgeries. METHODS: Adult patients admitted for implant removal in our department were included in the study. They were operated in the next OT list. They were then followed for an average 4 months for resolutions of symptoms or appearance of new problems. RESULTS: A total of 83 patients were studied. 71 of them were males. The mean age was 38 years. The reasons for removal of implants were found to lie in five categories: Pain/discomfort/prominent hardware, infected hardware, implant failure, elective (patient’s insistence), and other reasons. Overall, the most frequently removed implants in our series were distal tibial/ankle plates (14.45% of implants removed), femoral intramedullary (IM) nails (13.25%), olecranon wires and plates (12.04%), and tibial IM nails and patellar tension band wirings (9.53% each). DISCUSSION AND CONCLUSION: The clinical indications of implant removal are not well established, and few definitive data exist to guide whether routine implant removal is appropriate. Symptomatic hardware frequently needs removal. We found that pain and implant prominence (mechanical symptoms) are the most common indications. Infection is the next most common, followed by hardware failure. Other indications are implant failure, bone resorption due to excessive stress shielding and patient’s will. Removal is, however, not an easy surgery, and several factors such as bone ingrowth and wear of the implant may make its removal difficult. Qassim Uninversity 2017 /pmc/articles/PMC5327671/ /pubmed/28293156 Text en Copyright: © International Journal of Health Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Haseeb, Muhammad
Butt, Muhammad Farooq
Altaf, Tariq
Muzaffar, Khalid
Gupta, Anil
Jallu, Aleena
Indications of implant removal: A study of 83 cases
title Indications of implant removal: A study of 83 cases
title_full Indications of implant removal: A study of 83 cases
title_fullStr Indications of implant removal: A study of 83 cases
title_full_unstemmed Indications of implant removal: A study of 83 cases
title_short Indications of implant removal: A study of 83 cases
title_sort indications of implant removal: a study of 83 cases
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5327671/
https://www.ncbi.nlm.nih.gov/pubmed/28293156
work_keys_str_mv AT haseebmuhammad indicationsofimplantremovalastudyof83cases
AT buttmuhammadfarooq indicationsofimplantremovalastudyof83cases
AT altaftariq indicationsofimplantremovalastudyof83cases
AT muzaffarkhalid indicationsofimplantremovalastudyof83cases
AT guptaanil indicationsofimplantremovalastudyof83cases
AT jallualeena indicationsofimplantremovalastudyof83cases