Cargando…

FPL tendon thickness, tremor and hand functions in Parkinson’s disease

INTRODUCTION: In Parkinson’s disease (PD), a resting tremor of the thumb may affect the flexor pollicis longus (FPL) and influence hand functions. We investigated the relationship between FPL tendon thickness and hand function in PD patients and compared these characteristics with those in healthy c...

Descripción completa

Detalles Bibliográficos
Autores principales: Toktas, Hasan, Dundar, Umit, Kusbeci, Özge Yilmaz, Ulasli, Alper Murat, Toy, Ozgur, Oruc, Serdar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: De Gruyter Open 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5329791/
https://www.ncbi.nlm.nih.gov/pubmed/28352760
http://dx.doi.org/10.1515/med-2016-0004
_version_ 1782511126361145344
author Toktas, Hasan
Dundar, Umit
Kusbeci, Özge Yilmaz
Ulasli, Alper Murat
Toy, Ozgur
Oruc, Serdar
author_facet Toktas, Hasan
Dundar, Umit
Kusbeci, Özge Yilmaz
Ulasli, Alper Murat
Toy, Ozgur
Oruc, Serdar
author_sort Toktas, Hasan
collection PubMed
description INTRODUCTION: In Parkinson’s disease (PD), a resting tremor of the thumb may affect the flexor pollicis longus (FPL) and influence hand functions. We investigated the relationship between FPL tendon thickness and hand function in PD patients and compared these characteristics with those in healthy controls. METHODS: The hand grip and pinch strengths were measured. The participants completed the Duruöz hand index, the Sollerman’s hand function test, and the Nine Hole Peg Test. The thickness of the FPL tendon was measured using ultrasonography RESULTS: The FPL tendon was thicker in PD patients but was not associated with tremor severity. In PD patients, despite functional performance of the hands are impaired and grip strength is decreased, pinch strengths are preserved. FPL thickness was not correlated with grip and pinch strengths. CONCLUSION: The thicker FPL tendon may be associated with greater pinch and grip strengths and manual dexterity in healthy individuals. The presence of tremor is associated with a thicker FPL tendon.
format Online
Article
Text
id pubmed-5329791
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher De Gruyter Open
record_format MEDLINE/PubMed
spelling pubmed-53297912017-03-28 FPL tendon thickness, tremor and hand functions in Parkinson’s disease Toktas, Hasan Dundar, Umit Kusbeci, Özge Yilmaz Ulasli, Alper Murat Toy, Ozgur Oruc, Serdar Open Med (Wars) Research Article INTRODUCTION: In Parkinson’s disease (PD), a resting tremor of the thumb may affect the flexor pollicis longus (FPL) and influence hand functions. We investigated the relationship between FPL tendon thickness and hand function in PD patients and compared these characteristics with those in healthy controls. METHODS: The hand grip and pinch strengths were measured. The participants completed the Duruöz hand index, the Sollerman’s hand function test, and the Nine Hole Peg Test. The thickness of the FPL tendon was measured using ultrasonography RESULTS: The FPL tendon was thicker in PD patients but was not associated with tremor severity. In PD patients, despite functional performance of the hands are impaired and grip strength is decreased, pinch strengths are preserved. FPL thickness was not correlated with grip and pinch strengths. CONCLUSION: The thicker FPL tendon may be associated with greater pinch and grip strengths and manual dexterity in healthy individuals. The presence of tremor is associated with a thicker FPL tendon. De Gruyter Open 2016-02-19 /pmc/articles/PMC5329791/ /pubmed/28352760 http://dx.doi.org/10.1515/med-2016-0004 Text en © 2016 Hasan Toktas et al. http://creativecommons.org/licenses/by-nc-nd/3.0 This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
spellingShingle Research Article
Toktas, Hasan
Dundar, Umit
Kusbeci, Özge Yilmaz
Ulasli, Alper Murat
Toy, Ozgur
Oruc, Serdar
FPL tendon thickness, tremor and hand functions in Parkinson’s disease
title FPL tendon thickness, tremor and hand functions in Parkinson’s disease
title_full FPL tendon thickness, tremor and hand functions in Parkinson’s disease
title_fullStr FPL tendon thickness, tremor and hand functions in Parkinson’s disease
title_full_unstemmed FPL tendon thickness, tremor and hand functions in Parkinson’s disease
title_short FPL tendon thickness, tremor and hand functions in Parkinson’s disease
title_sort fpl tendon thickness, tremor and hand functions in parkinson’s disease
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5329791/
https://www.ncbi.nlm.nih.gov/pubmed/28352760
http://dx.doi.org/10.1515/med-2016-0004
work_keys_str_mv AT toktashasan fpltendonthicknesstremorandhandfunctionsinparkinsonsdisease
AT dundarumit fpltendonthicknesstremorandhandfunctionsinparkinsonsdisease
AT kusbeciozgeyilmaz fpltendonthicknesstremorandhandfunctionsinparkinsonsdisease
AT ulaslialpermurat fpltendonthicknesstremorandhandfunctionsinparkinsonsdisease
AT toyozgur fpltendonthicknesstremorandhandfunctionsinparkinsonsdisease
AT orucserdar fpltendonthicknesstremorandhandfunctionsinparkinsonsdisease