Cargando…
FPL tendon thickness, tremor and hand functions in Parkinson’s disease
INTRODUCTION: In Parkinson’s disease (PD), a resting tremor of the thumb may affect the flexor pollicis longus (FPL) and influence hand functions. We investigated the relationship between FPL tendon thickness and hand function in PD patients and compared these characteristics with those in healthy c...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
De Gruyter Open
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5329791/ https://www.ncbi.nlm.nih.gov/pubmed/28352760 http://dx.doi.org/10.1515/med-2016-0004 |
_version_ | 1782511126361145344 |
---|---|
author | Toktas, Hasan Dundar, Umit Kusbeci, Özge Yilmaz Ulasli, Alper Murat Toy, Ozgur Oruc, Serdar |
author_facet | Toktas, Hasan Dundar, Umit Kusbeci, Özge Yilmaz Ulasli, Alper Murat Toy, Ozgur Oruc, Serdar |
author_sort | Toktas, Hasan |
collection | PubMed |
description | INTRODUCTION: In Parkinson’s disease (PD), a resting tremor of the thumb may affect the flexor pollicis longus (FPL) and influence hand functions. We investigated the relationship between FPL tendon thickness and hand function in PD patients and compared these characteristics with those in healthy controls. METHODS: The hand grip and pinch strengths were measured. The participants completed the Duruöz hand index, the Sollerman’s hand function test, and the Nine Hole Peg Test. The thickness of the FPL tendon was measured using ultrasonography RESULTS: The FPL tendon was thicker in PD patients but was not associated with tremor severity. In PD patients, despite functional performance of the hands are impaired and grip strength is decreased, pinch strengths are preserved. FPL thickness was not correlated with grip and pinch strengths. CONCLUSION: The thicker FPL tendon may be associated with greater pinch and grip strengths and manual dexterity in healthy individuals. The presence of tremor is associated with a thicker FPL tendon. |
format | Online Article Text |
id | pubmed-5329791 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | De Gruyter Open |
record_format | MEDLINE/PubMed |
spelling | pubmed-53297912017-03-28 FPL tendon thickness, tremor and hand functions in Parkinson’s disease Toktas, Hasan Dundar, Umit Kusbeci, Özge Yilmaz Ulasli, Alper Murat Toy, Ozgur Oruc, Serdar Open Med (Wars) Research Article INTRODUCTION: In Parkinson’s disease (PD), a resting tremor of the thumb may affect the flexor pollicis longus (FPL) and influence hand functions. We investigated the relationship between FPL tendon thickness and hand function in PD patients and compared these characteristics with those in healthy controls. METHODS: The hand grip and pinch strengths were measured. The participants completed the Duruöz hand index, the Sollerman’s hand function test, and the Nine Hole Peg Test. The thickness of the FPL tendon was measured using ultrasonography RESULTS: The FPL tendon was thicker in PD patients but was not associated with tremor severity. In PD patients, despite functional performance of the hands are impaired and grip strength is decreased, pinch strengths are preserved. FPL thickness was not correlated with grip and pinch strengths. CONCLUSION: The thicker FPL tendon may be associated with greater pinch and grip strengths and manual dexterity in healthy individuals. The presence of tremor is associated with a thicker FPL tendon. De Gruyter Open 2016-02-19 /pmc/articles/PMC5329791/ /pubmed/28352760 http://dx.doi.org/10.1515/med-2016-0004 Text en © 2016 Hasan Toktas et al. http://creativecommons.org/licenses/by-nc-nd/3.0 This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License. |
spellingShingle | Research Article Toktas, Hasan Dundar, Umit Kusbeci, Özge Yilmaz Ulasli, Alper Murat Toy, Ozgur Oruc, Serdar FPL tendon thickness, tremor and hand functions in Parkinson’s disease |
title | FPL tendon thickness, tremor and hand functions in Parkinson’s disease |
title_full | FPL tendon thickness, tremor and hand functions in Parkinson’s disease |
title_fullStr | FPL tendon thickness, tremor and hand functions in Parkinson’s disease |
title_full_unstemmed | FPL tendon thickness, tremor and hand functions in Parkinson’s disease |
title_short | FPL tendon thickness, tremor and hand functions in Parkinson’s disease |
title_sort | fpl tendon thickness, tremor and hand functions in parkinson’s disease |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5329791/ https://www.ncbi.nlm.nih.gov/pubmed/28352760 http://dx.doi.org/10.1515/med-2016-0004 |
work_keys_str_mv | AT toktashasan fpltendonthicknesstremorandhandfunctionsinparkinsonsdisease AT dundarumit fpltendonthicknesstremorandhandfunctionsinparkinsonsdisease AT kusbeciozgeyilmaz fpltendonthicknesstremorandhandfunctionsinparkinsonsdisease AT ulaslialpermurat fpltendonthicknesstremorandhandfunctionsinparkinsonsdisease AT toyozgur fpltendonthicknesstremorandhandfunctionsinparkinsonsdisease AT orucserdar fpltendonthicknesstremorandhandfunctionsinparkinsonsdisease |