Cargando…

Effect of Noise on Time-frequency Analysis of Vibrocardiographic Signals

Recordings of biological signals such as vibrocardiography often contain contaminating noise. Noise sources may include respiratory, gastrointestinal, and muscles movement, or environmental noise. Depending on individual physiology and sensor location, the vibrocardiographic (VCG) signals may be obs...

Descripción completa

Detalles Bibliográficos
Autores principales: Taebi, A, Mansy, HA
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5330311/
https://www.ncbi.nlm.nih.gov/pubmed/28255516
http://dx.doi.org/10.4172/2155-9538.1000202
_version_ 1782511224503664640
author Taebi, A
Mansy, HA
author_facet Taebi, A
Mansy, HA
author_sort Taebi, A
collection PubMed
description Recordings of biological signals such as vibrocardiography often contain contaminating noise. Noise sources may include respiratory, gastrointestinal, and muscles movement, or environmental noise. Depending on individual physiology and sensor location, the vibrocardiographic (VCG) signals may be obscured by these noises in the time-frequency plane, which may interfere with automated characterization of VCG. In this study, polynomial chirplet transform (PCT) and smoothed pseudo Wigner-Ville distribution (SPWVD) were used to estimate the instantaneous frequency (IF) of two simulated VCG signals. One simulated signal contained a time-varying IF while the other had a fixed IF. The error in estimating IF was then calculated for signal-to-noise ratios (SNR) from −10 to 10 dB. Analysis was repeated 100 times at each level of noise using randomized sets of white noise. Error analysis showed that the range of errors in estimating IF was wider when SNR decreased. Results also showed that PCT tended to outperform SPWVD at high SNR. For example, PCT was more accurate at SNR > 3 dB for a simulated VCG signal with constant frequency components, at SNR>−10 dB for a simulated VCG signal with time-varying frequency, and at SNR > 0 for an actual VCG.
format Online
Article
Text
id pubmed-5330311
institution National Center for Biotechnology Information
language English
publishDate 2016
record_format MEDLINE/PubMed
spelling pubmed-53303112017-02-28 Effect of Noise on Time-frequency Analysis of Vibrocardiographic Signals Taebi, A Mansy, HA J Bioeng Biomed Sci Article Recordings of biological signals such as vibrocardiography often contain contaminating noise. Noise sources may include respiratory, gastrointestinal, and muscles movement, or environmental noise. Depending on individual physiology and sensor location, the vibrocardiographic (VCG) signals may be obscured by these noises in the time-frequency plane, which may interfere with automated characterization of VCG. In this study, polynomial chirplet transform (PCT) and smoothed pseudo Wigner-Ville distribution (SPWVD) were used to estimate the instantaneous frequency (IF) of two simulated VCG signals. One simulated signal contained a time-varying IF while the other had a fixed IF. The error in estimating IF was then calculated for signal-to-noise ratios (SNR) from −10 to 10 dB. Analysis was repeated 100 times at each level of noise using randomized sets of white noise. Error analysis showed that the range of errors in estimating IF was wider when SNR decreased. Results also showed that PCT tended to outperform SPWVD at high SNR. For example, PCT was more accurate at SNR > 3 dB for a simulated VCG signal with constant frequency components, at SNR>−10 dB for a simulated VCG signal with time-varying frequency, and at SNR > 0 for an actual VCG. 2016-09-15 2016-09 /pmc/articles/PMC5330311/ /pubmed/28255516 http://dx.doi.org/10.4172/2155-9538.1000202 Text en http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Article
Taebi, A
Mansy, HA
Effect of Noise on Time-frequency Analysis of Vibrocardiographic Signals
title Effect of Noise on Time-frequency Analysis of Vibrocardiographic Signals
title_full Effect of Noise on Time-frequency Analysis of Vibrocardiographic Signals
title_fullStr Effect of Noise on Time-frequency Analysis of Vibrocardiographic Signals
title_full_unstemmed Effect of Noise on Time-frequency Analysis of Vibrocardiographic Signals
title_short Effect of Noise on Time-frequency Analysis of Vibrocardiographic Signals
title_sort effect of noise on time-frequency analysis of vibrocardiographic signals
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5330311/
https://www.ncbi.nlm.nih.gov/pubmed/28255516
http://dx.doi.org/10.4172/2155-9538.1000202
work_keys_str_mv AT taebia effectofnoiseontimefrequencyanalysisofvibrocardiographicsignals
AT mansyha effectofnoiseontimefrequencyanalysisofvibrocardiographicsignals