Cargando…
How Mechanical Ventilation Measurement, Cutoff and Duration Affect Rapid Shallow Breathing Index Accuracy: A Randomized Trial
BACKGROUND: Decreased accuracy of the rapid shallow breathing index (RSBI) can stem from 1) the method used to obtain this index, 2) duration of mechanical ventilation (MV), and 3) the established cutoff point. The objective was to evaluate the values of RSBI determined by three different methods, u...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elmer Press
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5330771/ https://www.ncbi.nlm.nih.gov/pubmed/28270888 http://dx.doi.org/10.14740/jocmr2856w |
_version_ | 1782511270792003584 |
---|---|
author | Goncalves, Elaine Cristina Lago, Alessandra Fabiane Silva, Elaine Caetano de Almeida, Marcelo Barros Basile-Filho, Anibal Gastaldi, Ada Clarice |
author_facet | Goncalves, Elaine Cristina Lago, Alessandra Fabiane Silva, Elaine Caetano de Almeida, Marcelo Barros Basile-Filho, Anibal Gastaldi, Ada Clarice |
author_sort | Goncalves, Elaine Cristina |
collection | PubMed |
description | BACKGROUND: Decreased accuracy of the rapid shallow breathing index (RSBI) can stem from 1) the method used to obtain this index, 2) duration of mechanical ventilation (MV), and 3) the established cutoff point. The objective was to evaluate the values of RSBI determined by three different methods, using distinct MV times and cutoff points. METHODS: This prospective study included 40 subjects. Before extubation, three different methods were employed to measure RSBI: pressure support ventilator (PSV) (PSV = 5 - 8 cm H(2)O; positive end-expiratory pressure (PEEP) = 5 cm H(2)O) (RSBI_MIN), automatic tube compensation (ATC) (PSV = 0, PEEP = 5 cm H(2)O, and 100% tube compensation) (RSBI_ATC), and disconnected MV (RSBI_SP). The results were analyzed according to the MV period (less than or over 72 h) and to the outcome of extubation (< 72 h, successful and failed; > 72 h successful and failed). The accuracy of each method was determined at different cutoff points (105, 78, and 50 cycles/min/L). RESULTS: The RSBI_MIN, RSBI_ATC, and RSBI_SP values in the group < 72 h were 38 ± 18, 45 ± 26 and 55 ± 22; in the group > 72 h, RSBI_SP value was higher than those of RSBI_ATC and RSBI_MIN (78 ± 29, 51 ± 19 and 39 ± 14) (P < 0.001). For patients with MV > 72 h who failed in removing MV, the RSBI_SP was higher (93 ± 28, 58 ± 18 and 41 ± 10) (P < 0.000), with greater accuracy at cutoff of 78. CONCLUSION: RSBI_SP associated with cutoff point < 78 cycles/min/L seems to be the best strategy to identify failed extubation in subjects with MV for over 72 h. |
format | Online Article Text |
id | pubmed-5330771 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Elmer Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-53307712017-03-07 How Mechanical Ventilation Measurement, Cutoff and Duration Affect Rapid Shallow Breathing Index Accuracy: A Randomized Trial Goncalves, Elaine Cristina Lago, Alessandra Fabiane Silva, Elaine Caetano de Almeida, Marcelo Barros Basile-Filho, Anibal Gastaldi, Ada Clarice J Clin Med Res Original Article BACKGROUND: Decreased accuracy of the rapid shallow breathing index (RSBI) can stem from 1) the method used to obtain this index, 2) duration of mechanical ventilation (MV), and 3) the established cutoff point. The objective was to evaluate the values of RSBI determined by three different methods, using distinct MV times and cutoff points. METHODS: This prospective study included 40 subjects. Before extubation, three different methods were employed to measure RSBI: pressure support ventilator (PSV) (PSV = 5 - 8 cm H(2)O; positive end-expiratory pressure (PEEP) = 5 cm H(2)O) (RSBI_MIN), automatic tube compensation (ATC) (PSV = 0, PEEP = 5 cm H(2)O, and 100% tube compensation) (RSBI_ATC), and disconnected MV (RSBI_SP). The results were analyzed according to the MV period (less than or over 72 h) and to the outcome of extubation (< 72 h, successful and failed; > 72 h successful and failed). The accuracy of each method was determined at different cutoff points (105, 78, and 50 cycles/min/L). RESULTS: The RSBI_MIN, RSBI_ATC, and RSBI_SP values in the group < 72 h were 38 ± 18, 45 ± 26 and 55 ± 22; in the group > 72 h, RSBI_SP value was higher than those of RSBI_ATC and RSBI_MIN (78 ± 29, 51 ± 19 and 39 ± 14) (P < 0.001). For patients with MV > 72 h who failed in removing MV, the RSBI_SP was higher (93 ± 28, 58 ± 18 and 41 ± 10) (P < 0.000), with greater accuracy at cutoff of 78. CONCLUSION: RSBI_SP associated with cutoff point < 78 cycles/min/L seems to be the best strategy to identify failed extubation in subjects with MV for over 72 h. Elmer Press 2017-04 2017-02-21 /pmc/articles/PMC5330771/ /pubmed/28270888 http://dx.doi.org/10.14740/jocmr2856w Text en Copyright 2017, Goncalves et al. http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Non-Commercial 4.0 International License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Goncalves, Elaine Cristina Lago, Alessandra Fabiane Silva, Elaine Caetano de Almeida, Marcelo Barros Basile-Filho, Anibal Gastaldi, Ada Clarice How Mechanical Ventilation Measurement, Cutoff and Duration Affect Rapid Shallow Breathing Index Accuracy: A Randomized Trial |
title | How Mechanical Ventilation Measurement, Cutoff and Duration Affect Rapid Shallow Breathing Index Accuracy: A Randomized Trial |
title_full | How Mechanical Ventilation Measurement, Cutoff and Duration Affect Rapid Shallow Breathing Index Accuracy: A Randomized Trial |
title_fullStr | How Mechanical Ventilation Measurement, Cutoff and Duration Affect Rapid Shallow Breathing Index Accuracy: A Randomized Trial |
title_full_unstemmed | How Mechanical Ventilation Measurement, Cutoff and Duration Affect Rapid Shallow Breathing Index Accuracy: A Randomized Trial |
title_short | How Mechanical Ventilation Measurement, Cutoff and Duration Affect Rapid Shallow Breathing Index Accuracy: A Randomized Trial |
title_sort | how mechanical ventilation measurement, cutoff and duration affect rapid shallow breathing index accuracy: a randomized trial |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5330771/ https://www.ncbi.nlm.nih.gov/pubmed/28270888 http://dx.doi.org/10.14740/jocmr2856w |
work_keys_str_mv | AT goncalveselainecristina howmechanicalventilationmeasurementcutoffanddurationaffectrapidshallowbreathingindexaccuracyarandomizedtrial AT lagoalessandrafabiane howmechanicalventilationmeasurementcutoffanddurationaffectrapidshallowbreathingindexaccuracyarandomizedtrial AT silvaelainecaetano howmechanicalventilationmeasurementcutoffanddurationaffectrapidshallowbreathingindexaccuracyarandomizedtrial AT dealmeidamarcelobarros howmechanicalventilationmeasurementcutoffanddurationaffectrapidshallowbreathingindexaccuracyarandomizedtrial AT basilefilhoanibal howmechanicalventilationmeasurementcutoffanddurationaffectrapidshallowbreathingindexaccuracyarandomizedtrial AT gastaldiadaclarice howmechanicalventilationmeasurementcutoffanddurationaffectrapidshallowbreathingindexaccuracyarandomizedtrial |