Using a respiratory navigator significantly reduces variability when quantifying left ventricular torsion with cardiovascular magnetic resonance

BACKGROUND: Left ventricular (LV) torsion is an important indicator of cardiac function that is limited by high inter-test variability (50% of the mean value). We hypothesized that this high inter-test variability is partly due to inconsistent breath-hold positions during serial image acquisitions,...

Descripción completa

Detalles Bibliográficos
Autores principales: Hamlet, Sean M., Haggerty, Christopher M., Suever, Jonathan D., Wehner, Gregory J., Andres, Kristin N., Powell, David K., Charnigo, Richard J., Fornwalt, Brandon K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5331707/
https://www.ncbi.nlm.nih.gov/pubmed/28245864
http://dx.doi.org/10.1186/s12968-017-0338-6
_version_ 1782511431689699328
author Hamlet, Sean M.
Haggerty, Christopher M.
Suever, Jonathan D.
Wehner, Gregory J.
Andres, Kristin N.
Powell, David K.
Charnigo, Richard J.
Fornwalt, Brandon K.
author_facet Hamlet, Sean M.
Haggerty, Christopher M.
Suever, Jonathan D.
Wehner, Gregory J.
Andres, Kristin N.
Powell, David K.
Charnigo, Richard J.
Fornwalt, Brandon K.
author_sort Hamlet, Sean M.
collection PubMed
description BACKGROUND: Left ventricular (LV) torsion is an important indicator of cardiac function that is limited by high inter-test variability (50% of the mean value). We hypothesized that this high inter-test variability is partly due to inconsistent breath-hold positions during serial image acquisitions, which could be significantly improved by using a respiratory navigator for cardiovascular magnetic resonance (CMR) based quantification of LV torsion. METHODS: We assessed respiratory-related variability in measured LV torsion with two distinct experimental protocols. First, 17 volunteers were recruited for CMR with cine displacement encoding with stimulated echoes (DENSE) in which a respiratory navigator was used to measure and then enforce variability in end-expiratory position between all LV basal and apical acquisitions. From these data, we quantified the inter-test variability of torsion in the absence and presence of enforced end-expiratory position variability, which established an upper bound for the expected torsion variability. For the second experiment (in 20 new, healthy volunteers), 10 pairs of cine DENSE basal and apical images were each acquired from consecutive breath-holds and consecutive navigator-gated scans (with a single acceptance position). Inter-test variability of torsion was compared between the breath-hold and navigator-gated scans to quantify the variability due to natural breath-hold variation. To demonstrate the importance of these variability reductions, we quantified the reduction in sample size required to detect a clinically meaningful change in LV torsion with the use of a respiratory navigator. RESULTS: The mean torsion was 3.4 ± 0.2°/cm. From the first experiment, enforced variability in end-expiratory position translated to considerable variability in measured torsion (0.56 ± 0.34°/cm), whereas inter-test variability with consistent end-expiratory position was 57% lower (0.24 ± 0.16°/cm, p < 0.001). From the second experiment, natural respiratory variability from consecutive breath-holds translated to a variability in torsion of 0.24 ± 0.10°/cm, which was significantly higher than the variability from navigator-gated scans (0.18 ± 0.06°/cm, p = 0.02). By using a respiratory navigator with DENSE, theoretical sample sizes were reduced from 66 to 16 and 26 to 15 as calculated from the two experiments. CONCLUSIONS: A substantial portion (22-57%) of the inter-test variability of LV torsion can be reduced by using a respiratory navigator to ensure a consistent breath-hold position between image acquisitions.
format Online
Article
Text
id pubmed-5331707
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-53317072017-03-06 Using a respiratory navigator significantly reduces variability when quantifying left ventricular torsion with cardiovascular magnetic resonance Hamlet, Sean M. Haggerty, Christopher M. Suever, Jonathan D. Wehner, Gregory J. Andres, Kristin N. Powell, David K. Charnigo, Richard J. Fornwalt, Brandon K. J Cardiovasc Magn Reson Research BACKGROUND: Left ventricular (LV) torsion is an important indicator of cardiac function that is limited by high inter-test variability (50% of the mean value). We hypothesized that this high inter-test variability is partly due to inconsistent breath-hold positions during serial image acquisitions, which could be significantly improved by using a respiratory navigator for cardiovascular magnetic resonance (CMR) based quantification of LV torsion. METHODS: We assessed respiratory-related variability in measured LV torsion with two distinct experimental protocols. First, 17 volunteers were recruited for CMR with cine displacement encoding with stimulated echoes (DENSE) in which a respiratory navigator was used to measure and then enforce variability in end-expiratory position between all LV basal and apical acquisitions. From these data, we quantified the inter-test variability of torsion in the absence and presence of enforced end-expiratory position variability, which established an upper bound for the expected torsion variability. For the second experiment (in 20 new, healthy volunteers), 10 pairs of cine DENSE basal and apical images were each acquired from consecutive breath-holds and consecutive navigator-gated scans (with a single acceptance position). Inter-test variability of torsion was compared between the breath-hold and navigator-gated scans to quantify the variability due to natural breath-hold variation. To demonstrate the importance of these variability reductions, we quantified the reduction in sample size required to detect a clinically meaningful change in LV torsion with the use of a respiratory navigator. RESULTS: The mean torsion was 3.4 ± 0.2°/cm. From the first experiment, enforced variability in end-expiratory position translated to considerable variability in measured torsion (0.56 ± 0.34°/cm), whereas inter-test variability with consistent end-expiratory position was 57% lower (0.24 ± 0.16°/cm, p < 0.001). From the second experiment, natural respiratory variability from consecutive breath-holds translated to a variability in torsion of 0.24 ± 0.10°/cm, which was significantly higher than the variability from navigator-gated scans (0.18 ± 0.06°/cm, p = 0.02). By using a respiratory navigator with DENSE, theoretical sample sizes were reduced from 66 to 16 and 26 to 15 as calculated from the two experiments. CONCLUSIONS: A substantial portion (22-57%) of the inter-test variability of LV torsion can be reduced by using a respiratory navigator to ensure a consistent breath-hold position between image acquisitions. BioMed Central 2017-03-01 /pmc/articles/PMC5331707/ /pubmed/28245864 http://dx.doi.org/10.1186/s12968-017-0338-6 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Hamlet, Sean M.
Haggerty, Christopher M.
Suever, Jonathan D.
Wehner, Gregory J.
Andres, Kristin N.
Powell, David K.
Charnigo, Richard J.
Fornwalt, Brandon K.
Using a respiratory navigator significantly reduces variability when quantifying left ventricular torsion with cardiovascular magnetic resonance
title Using a respiratory navigator significantly reduces variability when quantifying left ventricular torsion with cardiovascular magnetic resonance
title_full Using a respiratory navigator significantly reduces variability when quantifying left ventricular torsion with cardiovascular magnetic resonance
title_fullStr Using a respiratory navigator significantly reduces variability when quantifying left ventricular torsion with cardiovascular magnetic resonance
title_full_unstemmed Using a respiratory navigator significantly reduces variability when quantifying left ventricular torsion with cardiovascular magnetic resonance
title_short Using a respiratory navigator significantly reduces variability when quantifying left ventricular torsion with cardiovascular magnetic resonance
title_sort using a respiratory navigator significantly reduces variability when quantifying left ventricular torsion with cardiovascular magnetic resonance
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5331707/
https://www.ncbi.nlm.nih.gov/pubmed/28245864
http://dx.doi.org/10.1186/s12968-017-0338-6
work_keys_str_mv AT hamletseanm usingarespiratorynavigatorsignificantlyreducesvariabilitywhenquantifyingleftventriculartorsionwithcardiovascularmagneticresonance
AT haggertychristopherm usingarespiratorynavigatorsignificantlyreducesvariabilitywhenquantifyingleftventriculartorsionwithcardiovascularmagneticresonance
AT sueverjonathand usingarespiratorynavigatorsignificantlyreducesvariabilitywhenquantifyingleftventriculartorsionwithcardiovascularmagneticresonance
AT wehnergregoryj usingarespiratorynavigatorsignificantlyreducesvariabilitywhenquantifyingleftventriculartorsionwithcardiovascularmagneticresonance
AT andreskristinn usingarespiratorynavigatorsignificantlyreducesvariabilitywhenquantifyingleftventriculartorsionwithcardiovascularmagneticresonance
AT powelldavidk usingarespiratorynavigatorsignificantlyreducesvariabilitywhenquantifyingleftventriculartorsionwithcardiovascularmagneticresonance
AT charnigorichardj usingarespiratorynavigatorsignificantlyreducesvariabilitywhenquantifyingleftventriculartorsionwithcardiovascularmagneticresonance
AT fornwaltbrandonk usingarespiratorynavigatorsignificantlyreducesvariabilitywhenquantifyingleftventriculartorsionwithcardiovascularmagneticresonance