Cargando…

Dangerous practices in a hemodialysis unit in Vietnam identify from mixed methods

BACKGROUND: Non-compliance with infection control practices poses a serious risk to patients receiving chronic hemodialysis. We aimed to identify the type and frequency of non-compliance with infection control practices in a hemodialysis unit in Vietnam where a large outbreak of hepatitis C infectio...

Descripción completa

Detalles Bibliográficos
Autores principales: Duong, Minh Cuong, McLaws, Mary-Louise
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5333403/
https://www.ncbi.nlm.nih.gov/pubmed/28249573
http://dx.doi.org/10.1186/s12879-017-2290-3
_version_ 1782511699498106880
author Duong, Minh Cuong
McLaws, Mary-Louise
author_facet Duong, Minh Cuong
McLaws, Mary-Louise
author_sort Duong, Minh Cuong
collection PubMed
description BACKGROUND: Non-compliance with infection control practices poses a serious risk to patients receiving chronic hemodialysis. We aimed to identify the type and frequency of non-compliance with infection control practices in a hemodialysis unit in Vietnam where a large outbreak of hepatitis C infection had occurred. METHODS: Mixed methods approach included observations and discussions of non-compliance with all 12 nurses at the Hemodialysis Unit, District-6 Hospital in Ho Chi Minh City. Observations of nursing care activities were made between September 2013 and January 2014. Compliance with hand hygiene and glove use during nursing care activities were classified according to the potential for a serious risk of transmission of infection and reported as percentages. Each nurse was expected to provide 11 nursing care activities to three patients assigned per hemodialysis sessions. Activities were to be given on an individual patient-centered care basis, that is, one patient was to receive all 11 activities by their assigned nurse. On completion of the observations all nurses were enrolled in a focus group where observed non-compliance was discussed and transcripts were examined for themes. RESULTS: Hand hygiene compliance rate was low (27%, 95%CI 25%-28%, 1633/6140) regardless of classification of seriousness of risk from this breach. Although glove use (76%, 95%CI 74-78%, 1211/1586) and other personal protective equipment use (81%, 95%CI 78%-83%, 773/959) were high gloves were observed to be reused with multiple patients during a single nursing care activity provided to consecutive patients. Nurses explained the breakdown of providing nursing care activities on an individual patient-centered basis was a response to limited supply of gloves and hand hygiene facilities and was exacerbated by nursing being co-opted by overly demanding patients to provide services without delay. CONCLUSIONS: The adaption by the nurses to provide 11 single care activities to multiple consecutive patients in the absence of changing gloves and low hand hygiene compliance was potentially the central risk factor that facilitated the hepatitis C outbreak. Patient-centered care needs to be enforced to minimize multiple nurse-patient contacts that are associated with non-compliance classified as serious risk of infection transmission. Nurse empowerment to resist unreasonable patient demands may also be pivotal to assisting their compliance with hand hygiene and single patient-centered care. An audit program to measure infection control resources and practices may facilitate enforcement of the guidelines.
format Online
Article
Text
id pubmed-5333403
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-53334032017-03-06 Dangerous practices in a hemodialysis unit in Vietnam identify from mixed methods Duong, Minh Cuong McLaws, Mary-Louise BMC Infect Dis Research Article BACKGROUND: Non-compliance with infection control practices poses a serious risk to patients receiving chronic hemodialysis. We aimed to identify the type and frequency of non-compliance with infection control practices in a hemodialysis unit in Vietnam where a large outbreak of hepatitis C infection had occurred. METHODS: Mixed methods approach included observations and discussions of non-compliance with all 12 nurses at the Hemodialysis Unit, District-6 Hospital in Ho Chi Minh City. Observations of nursing care activities were made between September 2013 and January 2014. Compliance with hand hygiene and glove use during nursing care activities were classified according to the potential for a serious risk of transmission of infection and reported as percentages. Each nurse was expected to provide 11 nursing care activities to three patients assigned per hemodialysis sessions. Activities were to be given on an individual patient-centered care basis, that is, one patient was to receive all 11 activities by their assigned nurse. On completion of the observations all nurses were enrolled in a focus group where observed non-compliance was discussed and transcripts were examined for themes. RESULTS: Hand hygiene compliance rate was low (27%, 95%CI 25%-28%, 1633/6140) regardless of classification of seriousness of risk from this breach. Although glove use (76%, 95%CI 74-78%, 1211/1586) and other personal protective equipment use (81%, 95%CI 78%-83%, 773/959) were high gloves were observed to be reused with multiple patients during a single nursing care activity provided to consecutive patients. Nurses explained the breakdown of providing nursing care activities on an individual patient-centered basis was a response to limited supply of gloves and hand hygiene facilities and was exacerbated by nursing being co-opted by overly demanding patients to provide services without delay. CONCLUSIONS: The adaption by the nurses to provide 11 single care activities to multiple consecutive patients in the absence of changing gloves and low hand hygiene compliance was potentially the central risk factor that facilitated the hepatitis C outbreak. Patient-centered care needs to be enforced to minimize multiple nurse-patient contacts that are associated with non-compliance classified as serious risk of infection transmission. Nurse empowerment to resist unreasonable patient demands may also be pivotal to assisting their compliance with hand hygiene and single patient-centered care. An audit program to measure infection control resources and practices may facilitate enforcement of the guidelines. BioMed Central 2017-03-01 /pmc/articles/PMC5333403/ /pubmed/28249573 http://dx.doi.org/10.1186/s12879-017-2290-3 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Duong, Minh Cuong
McLaws, Mary-Louise
Dangerous practices in a hemodialysis unit in Vietnam identify from mixed methods
title Dangerous practices in a hemodialysis unit in Vietnam identify from mixed methods
title_full Dangerous practices in a hemodialysis unit in Vietnam identify from mixed methods
title_fullStr Dangerous practices in a hemodialysis unit in Vietnam identify from mixed methods
title_full_unstemmed Dangerous practices in a hemodialysis unit in Vietnam identify from mixed methods
title_short Dangerous practices in a hemodialysis unit in Vietnam identify from mixed methods
title_sort dangerous practices in a hemodialysis unit in vietnam identify from mixed methods
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5333403/
https://www.ncbi.nlm.nih.gov/pubmed/28249573
http://dx.doi.org/10.1186/s12879-017-2290-3
work_keys_str_mv AT duongminhcuong dangerouspracticesinahemodialysisunitinvietnamidentifyfrommixedmethods
AT mclawsmarylouise dangerouspracticesinahemodialysisunitinvietnamidentifyfrommixedmethods