Cargando…

Prospective Case Study of Outcome of Tibial Plateau Fractures Treated with Locking Condylar Plate

Introduction: Tibial plateau injury involves the articular surface of the proximal tibia with diverse group of fractures that represent a wide spectrum of severity that challenge even the most experienced surgeons, but with the invent of modern diagnostic technology and the advent of locking plates,...

Descripción completa

Detalles Bibliográficos
Autor principal: Jain, R
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Malaysian Orthopaedic Association 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5333677/
https://www.ncbi.nlm.nih.gov/pubmed/28553441
http://dx.doi.org/10.5704/MOJ.1611.007
_version_ 1782511754617552896
author Jain, R
author_facet Jain, R
author_sort Jain, R
collection PubMed
description Introduction: Tibial plateau injury involves the articular surface of the proximal tibia with diverse group of fractures that represent a wide spectrum of severity that challenge even the most experienced surgeons, but with the invent of modern diagnostic technology and the advent of locking plates, results appear to be improving over time. Method: The study was conducted on thirty patients admitted in the department of orthopaedics with diagnoses of tibial plateau fractures treated with Locking Condylar Plate. The patients were followed up for a minimum period of six months and clinico-radiological progression of fracture union with the functional outcome was studied using 100 point rating system devised by Delamarter et al. Result: Twenty-two patients showed excellent results while eight patients had good to fair and none with poor result. The average time for radiological union was 17.5 weeks. Conclusion: The results of the study concluded that while locking condylar plate seems to show excellent results in low energy tibial plateau fractures, it can probably be used to successfully treat patients with high energy fracture patterns without the need for additional medial stabilization.
format Online
Article
Text
id pubmed-5333677
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Malaysian Orthopaedic Association
record_format MEDLINE/PubMed
spelling pubmed-53336772017-05-26 Prospective Case Study of Outcome of Tibial Plateau Fractures Treated with Locking Condylar Plate Jain, R Malays Orthop J Original Article Introduction: Tibial plateau injury involves the articular surface of the proximal tibia with diverse group of fractures that represent a wide spectrum of severity that challenge even the most experienced surgeons, but with the invent of modern diagnostic technology and the advent of locking plates, results appear to be improving over time. Method: The study was conducted on thirty patients admitted in the department of orthopaedics with diagnoses of tibial plateau fractures treated with Locking Condylar Plate. The patients were followed up for a minimum period of six months and clinico-radiological progression of fracture union with the functional outcome was studied using 100 point rating system devised by Delamarter et al. Result: Twenty-two patients showed excellent results while eight patients had good to fair and none with poor result. The average time for radiological union was 17.5 weeks. Conclusion: The results of the study concluded that while locking condylar plate seems to show excellent results in low energy tibial plateau fractures, it can probably be used to successfully treat patients with high energy fracture patterns without the need for additional medial stabilization. Malaysian Orthopaedic Association 2016-11 /pmc/articles/PMC5333677/ /pubmed/28553441 http://dx.doi.org/10.5704/MOJ.1611.007 Text en © 2016 Malaysian Orthopaedic Association (MOA). All Rights Reserved http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Jain, R
Prospective Case Study of Outcome of Tibial Plateau Fractures Treated with Locking Condylar Plate
title Prospective Case Study of Outcome of Tibial Plateau Fractures Treated with Locking Condylar Plate
title_full Prospective Case Study of Outcome of Tibial Plateau Fractures Treated with Locking Condylar Plate
title_fullStr Prospective Case Study of Outcome of Tibial Plateau Fractures Treated with Locking Condylar Plate
title_full_unstemmed Prospective Case Study of Outcome of Tibial Plateau Fractures Treated with Locking Condylar Plate
title_short Prospective Case Study of Outcome of Tibial Plateau Fractures Treated with Locking Condylar Plate
title_sort prospective case study of outcome of tibial plateau fractures treated with locking condylar plate
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5333677/
https://www.ncbi.nlm.nih.gov/pubmed/28553441
http://dx.doi.org/10.5704/MOJ.1611.007
work_keys_str_mv AT jainr prospectivecasestudyofoutcomeoftibialplateaufracturestreatedwithlockingcondylarplate