Cargando…
The Use of Dual Reconstruction Plates for Failed Fixation of Patellar Fracture after Total Knee Replacement: A Case Report
Patellar fracture after total knee replacement (TKR) is one of the challenging problems in periprosthetic fracture. Open reduction with internal fixation (ORIF), as tension band wiring (TBW), usually required in cases with extensor mechanism disruption. However, many studies reported a high failure...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Malaysian Orthopaedic Association
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5333687/ https://www.ncbi.nlm.nih.gov/pubmed/28553451 http://dx.doi.org/10.5704/MOJ.1611.012 |
_version_ | 1782511756835291136 |
---|---|
author | Sa-ngasoongsong, P Chulsomlee, K Wongsak, S Suphachatwong, C Kawinwonggowit, V |
author_facet | Sa-ngasoongsong, P Chulsomlee, K Wongsak, S Suphachatwong, C Kawinwonggowit, V |
author_sort | Sa-ngasoongsong, P |
collection | PubMed |
description | Patellar fracture after total knee replacement (TKR) is one of the challenging problems in periprosthetic fracture. Open reduction with internal fixation (ORIF), as tension band wiring (TBW), usually required in cases with extensor mechanism disruption. However, many studies reported a high failure rate after using this technique. In this report, we presented an interesting case of periprosthetic patellar fracture after TKR with TBW failure that was successfully treated with double non-locking reconstruction plates fixation and TBW augmentation. |
format | Online Article Text |
id | pubmed-5333687 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Malaysian Orthopaedic Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-53336872017-05-26 The Use of Dual Reconstruction Plates for Failed Fixation of Patellar Fracture after Total Knee Replacement: A Case Report Sa-ngasoongsong, P Chulsomlee, K Wongsak, S Suphachatwong, C Kawinwonggowit, V Malays Orthop J Case Report Patellar fracture after total knee replacement (TKR) is one of the challenging problems in periprosthetic fracture. Open reduction with internal fixation (ORIF), as tension band wiring (TBW), usually required in cases with extensor mechanism disruption. However, many studies reported a high failure rate after using this technique. In this report, we presented an interesting case of periprosthetic patellar fracture after TKR with TBW failure that was successfully treated with double non-locking reconstruction plates fixation and TBW augmentation. Malaysian Orthopaedic Association 2016-11 /pmc/articles/PMC5333687/ /pubmed/28553451 http://dx.doi.org/10.5704/MOJ.1611.012 Text en © 2016 Malaysian Orthopaedic Association (MOA). All Rights Reserved http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Sa-ngasoongsong, P Chulsomlee, K Wongsak, S Suphachatwong, C Kawinwonggowit, V The Use of Dual Reconstruction Plates for Failed Fixation of Patellar Fracture after Total Knee Replacement: A Case Report |
title | The Use of Dual Reconstruction Plates for Failed Fixation of Patellar Fracture after Total Knee Replacement: A Case Report |
title_full | The Use of Dual Reconstruction Plates for Failed Fixation of Patellar Fracture after Total Knee Replacement: A Case Report |
title_fullStr | The Use of Dual Reconstruction Plates for Failed Fixation of Patellar Fracture after Total Knee Replacement: A Case Report |
title_full_unstemmed | The Use of Dual Reconstruction Plates for Failed Fixation of Patellar Fracture after Total Knee Replacement: A Case Report |
title_short | The Use of Dual Reconstruction Plates for Failed Fixation of Patellar Fracture after Total Knee Replacement: A Case Report |
title_sort | use of dual reconstruction plates for failed fixation of patellar fracture after total knee replacement: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5333687/ https://www.ncbi.nlm.nih.gov/pubmed/28553451 http://dx.doi.org/10.5704/MOJ.1611.012 |
work_keys_str_mv | AT sangasoongsongp theuseofdualreconstructionplatesforfailedfixationofpatellarfractureaftertotalkneereplacementacasereport AT chulsomleek theuseofdualreconstructionplatesforfailedfixationofpatellarfractureaftertotalkneereplacementacasereport AT wongsaks theuseofdualreconstructionplatesforfailedfixationofpatellarfractureaftertotalkneereplacementacasereport AT suphachatwongc theuseofdualreconstructionplatesforfailedfixationofpatellarfractureaftertotalkneereplacementacasereport AT kawinwonggowitv theuseofdualreconstructionplatesforfailedfixationofpatellarfractureaftertotalkneereplacementacasereport AT sangasoongsongp useofdualreconstructionplatesforfailedfixationofpatellarfractureaftertotalkneereplacementacasereport AT chulsomleek useofdualreconstructionplatesforfailedfixationofpatellarfractureaftertotalkneereplacementacasereport AT wongsaks useofdualreconstructionplatesforfailedfixationofpatellarfractureaftertotalkneereplacementacasereport AT suphachatwongc useofdualreconstructionplatesforfailedfixationofpatellarfractureaftertotalkneereplacementacasereport AT kawinwonggowitv useofdualreconstructionplatesforfailedfixationofpatellarfractureaftertotalkneereplacementacasereport |