Cargando…

Risk factors associated with bleeding after multi antithrombotic therapy during implantation of cardiac implantable electronic devices

Previous studies showed that continuous anticoagulation or single antiplatelet therapy during implantations of cardiac implantable electronic devices (CIED) was relatively safe. However, the safety of continuous multi antithrombotic therapy (AT) in patients undergoing CIED interventions has not been...

Descripción completa

Detalles Bibliográficos
Autores principales: Ishibashi, Kohei, Miyamoto, Koji, Kamakura, Tsukasa, Wada, Mitsuru, Nakajima, Ikutaro, Inoue, Yuko, Okamura, Hideo, Noda, Takashi, Aiba, Takeshi, Kamakura, Shiro, Shimizu, Wataru, Yasuda, Satoshi, Akasaka, Takashi, Kusano, Kengo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Japan 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5334385/
https://www.ncbi.nlm.nih.gov/pubmed/27469320
http://dx.doi.org/10.1007/s00380-016-0879-x
_version_ 1782511842398044160
author Ishibashi, Kohei
Miyamoto, Koji
Kamakura, Tsukasa
Wada, Mitsuru
Nakajima, Ikutaro
Inoue, Yuko
Okamura, Hideo
Noda, Takashi
Aiba, Takeshi
Kamakura, Shiro
Shimizu, Wataru
Yasuda, Satoshi
Akasaka, Takashi
Kusano, Kengo
author_facet Ishibashi, Kohei
Miyamoto, Koji
Kamakura, Tsukasa
Wada, Mitsuru
Nakajima, Ikutaro
Inoue, Yuko
Okamura, Hideo
Noda, Takashi
Aiba, Takeshi
Kamakura, Shiro
Shimizu, Wataru
Yasuda, Satoshi
Akasaka, Takashi
Kusano, Kengo
author_sort Ishibashi, Kohei
collection PubMed
description Previous studies showed that continuous anticoagulation or single antiplatelet therapy during implantations of cardiac implantable electronic devices (CIED) was relatively safe. However, the safety of continuous multi antithrombotic therapy (AT) in patients undergoing CIED interventions has not been clearly defined. We sought to evaluate the safety of this therapy during CIED implantations. A total of 300 consecutive patients (mean 69 years old, 171 males) with CIED implantations were enrolled in this study. The patients were divided into 6 groups [No-AT, oral anticoagulant therapy (OAT), single antiplatelet therapy (SAPT), OAT and SAPT, dual antiplatelet therapy (DAPT), triple AT (TAT)], and the perioperative complications were evaluated. Clinically significant pocket hematomas (PH) were defined as PH needing surgical intervention, prolonged hospitalizations, interruption of AT, or blood product transfusions. There were 129, 89, 49, 20, 10, and 3 patients in No-AT, OAT, SAPT, OAT + SAPT, DAPT, and TAT groups, respectively. The occurrence of clinically significant PH and thromboembolism did not differ among 6 groups (p = 0.145 and p = 0.795, respectively). However, high HAS-BLED score and valvular heart disease (VHD) were associated with clinically significant PH (p = 0.014 and p = 0.015, respectively). Continuous multi AT may be tolerated, but patients with high HAS-BLED score or VHD would require a careful attention during CIED implantations.
format Online
Article
Text
id pubmed-5334385
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer Japan
record_format MEDLINE/PubMed
spelling pubmed-53343852017-03-15 Risk factors associated with bleeding after multi antithrombotic therapy during implantation of cardiac implantable electronic devices Ishibashi, Kohei Miyamoto, Koji Kamakura, Tsukasa Wada, Mitsuru Nakajima, Ikutaro Inoue, Yuko Okamura, Hideo Noda, Takashi Aiba, Takeshi Kamakura, Shiro Shimizu, Wataru Yasuda, Satoshi Akasaka, Takashi Kusano, Kengo Heart Vessels Original Article Previous studies showed that continuous anticoagulation or single antiplatelet therapy during implantations of cardiac implantable electronic devices (CIED) was relatively safe. However, the safety of continuous multi antithrombotic therapy (AT) in patients undergoing CIED interventions has not been clearly defined. We sought to evaluate the safety of this therapy during CIED implantations. A total of 300 consecutive patients (mean 69 years old, 171 males) with CIED implantations were enrolled in this study. The patients were divided into 6 groups [No-AT, oral anticoagulant therapy (OAT), single antiplatelet therapy (SAPT), OAT and SAPT, dual antiplatelet therapy (DAPT), triple AT (TAT)], and the perioperative complications were evaluated. Clinically significant pocket hematomas (PH) were defined as PH needing surgical intervention, prolonged hospitalizations, interruption of AT, or blood product transfusions. There were 129, 89, 49, 20, 10, and 3 patients in No-AT, OAT, SAPT, OAT + SAPT, DAPT, and TAT groups, respectively. The occurrence of clinically significant PH and thromboembolism did not differ among 6 groups (p = 0.145 and p = 0.795, respectively). However, high HAS-BLED score and valvular heart disease (VHD) were associated with clinically significant PH (p = 0.014 and p = 0.015, respectively). Continuous multi AT may be tolerated, but patients with high HAS-BLED score or VHD would require a careful attention during CIED implantations. Springer Japan 2016-07-28 2017 /pmc/articles/PMC5334385/ /pubmed/27469320 http://dx.doi.org/10.1007/s00380-016-0879-x Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Ishibashi, Kohei
Miyamoto, Koji
Kamakura, Tsukasa
Wada, Mitsuru
Nakajima, Ikutaro
Inoue, Yuko
Okamura, Hideo
Noda, Takashi
Aiba, Takeshi
Kamakura, Shiro
Shimizu, Wataru
Yasuda, Satoshi
Akasaka, Takashi
Kusano, Kengo
Risk factors associated with bleeding after multi antithrombotic therapy during implantation of cardiac implantable electronic devices
title Risk factors associated with bleeding after multi antithrombotic therapy during implantation of cardiac implantable electronic devices
title_full Risk factors associated with bleeding after multi antithrombotic therapy during implantation of cardiac implantable electronic devices
title_fullStr Risk factors associated with bleeding after multi antithrombotic therapy during implantation of cardiac implantable electronic devices
title_full_unstemmed Risk factors associated with bleeding after multi antithrombotic therapy during implantation of cardiac implantable electronic devices
title_short Risk factors associated with bleeding after multi antithrombotic therapy during implantation of cardiac implantable electronic devices
title_sort risk factors associated with bleeding after multi antithrombotic therapy during implantation of cardiac implantable electronic devices
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5334385/
https://www.ncbi.nlm.nih.gov/pubmed/27469320
http://dx.doi.org/10.1007/s00380-016-0879-x
work_keys_str_mv AT ishibashikohei riskfactorsassociatedwithbleedingaftermultiantithrombotictherapyduringimplantationofcardiacimplantableelectronicdevices
AT miyamotokoji riskfactorsassociatedwithbleedingaftermultiantithrombotictherapyduringimplantationofcardiacimplantableelectronicdevices
AT kamakuratsukasa riskfactorsassociatedwithbleedingaftermultiantithrombotictherapyduringimplantationofcardiacimplantableelectronicdevices
AT wadamitsuru riskfactorsassociatedwithbleedingaftermultiantithrombotictherapyduringimplantationofcardiacimplantableelectronicdevices
AT nakajimaikutaro riskfactorsassociatedwithbleedingaftermultiantithrombotictherapyduringimplantationofcardiacimplantableelectronicdevices
AT inoueyuko riskfactorsassociatedwithbleedingaftermultiantithrombotictherapyduringimplantationofcardiacimplantableelectronicdevices
AT okamurahideo riskfactorsassociatedwithbleedingaftermultiantithrombotictherapyduringimplantationofcardiacimplantableelectronicdevices
AT nodatakashi riskfactorsassociatedwithbleedingaftermultiantithrombotictherapyduringimplantationofcardiacimplantableelectronicdevices
AT aibatakeshi riskfactorsassociatedwithbleedingaftermultiantithrombotictherapyduringimplantationofcardiacimplantableelectronicdevices
AT kamakurashiro riskfactorsassociatedwithbleedingaftermultiantithrombotictherapyduringimplantationofcardiacimplantableelectronicdevices
AT shimizuwataru riskfactorsassociatedwithbleedingaftermultiantithrombotictherapyduringimplantationofcardiacimplantableelectronicdevices
AT yasudasatoshi riskfactorsassociatedwithbleedingaftermultiantithrombotictherapyduringimplantationofcardiacimplantableelectronicdevices
AT akasakatakashi riskfactorsassociatedwithbleedingaftermultiantithrombotictherapyduringimplantationofcardiacimplantableelectronicdevices
AT kusanokengo riskfactorsassociatedwithbleedingaftermultiantithrombotictherapyduringimplantationofcardiacimplantableelectronicdevices