Cargando…

High-Sensitivity and Low-Hysteresis Porous MIM-Type Capacitive Humidity Sensor Using Functional Polymer Mixed with TiO(2) Microparticles

In this study, a high-sensitivity and low-hysteresis porous metal–insulator–metal-type capacitive humidity sensor is investigated using a functional polymer mixed with TiO(2) microparticles. The humidity sensor consists of an optimally designed porous top electrode, a functional polymer humidity sen...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Ming-Qing, Wang, Cong, Kim, Nam-Young
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5335950/
https://www.ncbi.nlm.nih.gov/pubmed/28157167
http://dx.doi.org/10.3390/s17020284
_version_ 1782512127644270592
author Liu, Ming-Qing
Wang, Cong
Kim, Nam-Young
author_facet Liu, Ming-Qing
Wang, Cong
Kim, Nam-Young
author_sort Liu, Ming-Qing
collection PubMed
description In this study, a high-sensitivity and low-hysteresis porous metal–insulator–metal-type capacitive humidity sensor is investigated using a functional polymer mixed with TiO(2) microparticles. The humidity sensor consists of an optimally designed porous top electrode, a functional polymer humidity sensitive layer, a bottom electrode, and a glass substrate. The porous top electrode is designed to increase the contact area between the sensing layer and water vapor, leading to high sensitivity and quick response time. The functional polymer mixed with TiO(2) microparticles shows excellent hysteresis under a wide humidity-sensing range with good long-term stability. The results show that as the relative humidity ranges from 10% RH to 90% RH, the proposed humidity sensor achieves a high sensitivity of 0.85 pF/% RH and a fast response time of less than 35 s. Furthermore, the sensor shows an ultra-low hysteresis of 0.95% RH at 60% RH, a good temperature dependence, and a stable capacitance value with a maximum of 0.17% RH drift during 120 h of continuous test.
format Online
Article
Text
id pubmed-5335950
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-53359502017-03-16 High-Sensitivity and Low-Hysteresis Porous MIM-Type Capacitive Humidity Sensor Using Functional Polymer Mixed with TiO(2) Microparticles Liu, Ming-Qing Wang, Cong Kim, Nam-Young Sensors (Basel) Article In this study, a high-sensitivity and low-hysteresis porous metal–insulator–metal-type capacitive humidity sensor is investigated using a functional polymer mixed with TiO(2) microparticles. The humidity sensor consists of an optimally designed porous top electrode, a functional polymer humidity sensitive layer, a bottom electrode, and a glass substrate. The porous top electrode is designed to increase the contact area between the sensing layer and water vapor, leading to high sensitivity and quick response time. The functional polymer mixed with TiO(2) microparticles shows excellent hysteresis under a wide humidity-sensing range with good long-term stability. The results show that as the relative humidity ranges from 10% RH to 90% RH, the proposed humidity sensor achieves a high sensitivity of 0.85 pF/% RH and a fast response time of less than 35 s. Furthermore, the sensor shows an ultra-low hysteresis of 0.95% RH at 60% RH, a good temperature dependence, and a stable capacitance value with a maximum of 0.17% RH drift during 120 h of continuous test. MDPI 2017-02-02 /pmc/articles/PMC5335950/ /pubmed/28157167 http://dx.doi.org/10.3390/s17020284 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Liu, Ming-Qing
Wang, Cong
Kim, Nam-Young
High-Sensitivity and Low-Hysteresis Porous MIM-Type Capacitive Humidity Sensor Using Functional Polymer Mixed with TiO(2) Microparticles
title High-Sensitivity and Low-Hysteresis Porous MIM-Type Capacitive Humidity Sensor Using Functional Polymer Mixed with TiO(2) Microparticles
title_full High-Sensitivity and Low-Hysteresis Porous MIM-Type Capacitive Humidity Sensor Using Functional Polymer Mixed with TiO(2) Microparticles
title_fullStr High-Sensitivity and Low-Hysteresis Porous MIM-Type Capacitive Humidity Sensor Using Functional Polymer Mixed with TiO(2) Microparticles
title_full_unstemmed High-Sensitivity and Low-Hysteresis Porous MIM-Type Capacitive Humidity Sensor Using Functional Polymer Mixed with TiO(2) Microparticles
title_short High-Sensitivity and Low-Hysteresis Porous MIM-Type Capacitive Humidity Sensor Using Functional Polymer Mixed with TiO(2) Microparticles
title_sort high-sensitivity and low-hysteresis porous mim-type capacitive humidity sensor using functional polymer mixed with tio(2) microparticles
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5335950/
https://www.ncbi.nlm.nih.gov/pubmed/28157167
http://dx.doi.org/10.3390/s17020284
work_keys_str_mv AT liumingqing highsensitivityandlowhysteresisporousmimtypecapacitivehumiditysensorusingfunctionalpolymermixedwithtio2microparticles
AT wangcong highsensitivityandlowhysteresisporousmimtypecapacitivehumiditysensorusingfunctionalpolymermixedwithtio2microparticles
AT kimnamyoung highsensitivityandlowhysteresisporousmimtypecapacitivehumiditysensorusingfunctionalpolymermixedwithtio2microparticles