Cargando…

A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts

The estimation of heart rate (HR) based on wearable devices is of interest in fitness. Photoplethysmography (PPG) is a promising approach to estimate HR due to low cost; however, it is easily corrupted by motion artifacts (MA). In this work, a robust approach based on random forest is proposed for a...

Descripción completa

Detalles Bibliográficos
Autores principales: Ye, Yalan, He, Wenwen, Cheng, Yunfei, Huang, Wenxia, Zhang, Zhilin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5335968/
https://www.ncbi.nlm.nih.gov/pubmed/28212327
http://dx.doi.org/10.3390/s17020385
_version_ 1782512131748397056
author Ye, Yalan
He, Wenwen
Cheng, Yunfei
Huang, Wenxia
Zhang, Zhilin
author_facet Ye, Yalan
He, Wenwen
Cheng, Yunfei
Huang, Wenxia
Zhang, Zhilin
author_sort Ye, Yalan
collection PubMed
description The estimation of heart rate (HR) based on wearable devices is of interest in fitness. Photoplethysmography (PPG) is a promising approach to estimate HR due to low cost; however, it is easily corrupted by motion artifacts (MA). In this work, a robust approach based on random forest is proposed for accurately estimating HR from the photoplethysmography signal contaminated by intense motion artifacts, consisting of two stages. Stage 1 proposes a hybrid method to effectively remove MA with a low computation complexity, where two MA removal algorithms are combined by an accurate binary decision algorithm whose aim is to decide whether or not to adopt the second MA removal algorithm. Stage 2 proposes a random forest-based spectral peak-tracking algorithm, whose aim is to locate the spectral peak corresponding to HR, formulating the problem of spectral peak tracking into a pattern classification problem. Experiments on the PPG datasets including 22 subjects used in the 2015 IEEE Signal Processing Cup showed that the proposed approach achieved the average absolute error of 1.65 beats per minute (BPM) on the 22 PPG datasets. Compared to state-of-the-art approaches, the proposed approach has better accuracy and robustness to intense motion artifacts, indicating its potential use in wearable sensors for health monitoring and fitness tracking.
format Online
Article
Text
id pubmed-5335968
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-53359682017-03-16 A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts Ye, Yalan He, Wenwen Cheng, Yunfei Huang, Wenxia Zhang, Zhilin Sensors (Basel) Article The estimation of heart rate (HR) based on wearable devices is of interest in fitness. Photoplethysmography (PPG) is a promising approach to estimate HR due to low cost; however, it is easily corrupted by motion artifacts (MA). In this work, a robust approach based on random forest is proposed for accurately estimating HR from the photoplethysmography signal contaminated by intense motion artifacts, consisting of two stages. Stage 1 proposes a hybrid method to effectively remove MA with a low computation complexity, where two MA removal algorithms are combined by an accurate binary decision algorithm whose aim is to decide whether or not to adopt the second MA removal algorithm. Stage 2 proposes a random forest-based spectral peak-tracking algorithm, whose aim is to locate the spectral peak corresponding to HR, formulating the problem of spectral peak tracking into a pattern classification problem. Experiments on the PPG datasets including 22 subjects used in the 2015 IEEE Signal Processing Cup showed that the proposed approach achieved the average absolute error of 1.65 beats per minute (BPM) on the 22 PPG datasets. Compared to state-of-the-art approaches, the proposed approach has better accuracy and robustness to intense motion artifacts, indicating its potential use in wearable sensors for health monitoring and fitness tracking. MDPI 2017-02-16 /pmc/articles/PMC5335968/ /pubmed/28212327 http://dx.doi.org/10.3390/s17020385 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ye, Yalan
He, Wenwen
Cheng, Yunfei
Huang, Wenxia
Zhang, Zhilin
A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts
title A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts
title_full A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts
title_fullStr A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts
title_full_unstemmed A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts
title_short A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts
title_sort robust random forest-based approach for heart rate monitoring using photoplethysmography signal contaminated by intense motion artifacts
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5335968/
https://www.ncbi.nlm.nih.gov/pubmed/28212327
http://dx.doi.org/10.3390/s17020385
work_keys_str_mv AT yeyalan arobustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts
AT hewenwen arobustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts
AT chengyunfei arobustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts
AT huangwenxia arobustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts
AT zhangzhilin arobustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts
AT yeyalan robustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts
AT hewenwen robustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts
AT chengyunfei robustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts
AT huangwenxia robustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts
AT zhangzhilin robustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts