Quasi-Static Calibration Method of a High-g Accelerometer

To solve the problem of resonance during quasi-static calibration of high-g accelerometers, we deduce the relationship between the minimum excitation pulse width and the resonant frequency of the calibrated accelerometer according to the second-order mathematical model of the accelerometer, and impr...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Yan, Fan, Jinbiao, Zu, Jing, Xu, Peng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5336105/
https://www.ncbi.nlm.nih.gov/pubmed/28230743
http://dx.doi.org/10.3390/s17020409
_version_ 1782512162869084160
author Wang, Yan
Fan, Jinbiao
Zu, Jing
Xu, Peng
author_facet Wang, Yan
Fan, Jinbiao
Zu, Jing
Xu, Peng
author_sort Wang, Yan
collection PubMed
description To solve the problem of resonance during quasi-static calibration of high-g accelerometers, we deduce the relationship between the minimum excitation pulse width and the resonant frequency of the calibrated accelerometer according to the second-order mathematical model of the accelerometer, and improve the quasi-static calibration theory. We establish a quasi-static calibration testing system, which uses a gas gun to generate high-g acceleration signals, and apply a laser interferometer to reproduce the impact acceleration. These signals are used to drive the calibrated accelerometer. By comparing the excitation acceleration signal and the output responses of the calibrated accelerometer to the excitation signals, the impact sensitivity of the calibrated accelerometer is obtained. As indicated by the calibration test results, this calibration system produces excitation acceleration signals with a pulse width of less than 1000 μs, and realize the quasi-static calibration of high-g accelerometers with a resonant frequency above 20 kHz when the calibration error was 3%.
format Online
Article
Text
id pubmed-5336105
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-53361052017-03-16 Quasi-Static Calibration Method of a High-g Accelerometer Wang, Yan Fan, Jinbiao Zu, Jing Xu, Peng Sensors (Basel) Article To solve the problem of resonance during quasi-static calibration of high-g accelerometers, we deduce the relationship between the minimum excitation pulse width and the resonant frequency of the calibrated accelerometer according to the second-order mathematical model of the accelerometer, and improve the quasi-static calibration theory. We establish a quasi-static calibration testing system, which uses a gas gun to generate high-g acceleration signals, and apply a laser interferometer to reproduce the impact acceleration. These signals are used to drive the calibrated accelerometer. By comparing the excitation acceleration signal and the output responses of the calibrated accelerometer to the excitation signals, the impact sensitivity of the calibrated accelerometer is obtained. As indicated by the calibration test results, this calibration system produces excitation acceleration signals with a pulse width of less than 1000 μs, and realize the quasi-static calibration of high-g accelerometers with a resonant frequency above 20 kHz when the calibration error was 3%. MDPI 2017-02-20 /pmc/articles/PMC5336105/ /pubmed/28230743 http://dx.doi.org/10.3390/s17020409 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wang, Yan
Fan, Jinbiao
Zu, Jing
Xu, Peng
Quasi-Static Calibration Method of a High-g Accelerometer
title Quasi-Static Calibration Method of a High-g Accelerometer
title_full Quasi-Static Calibration Method of a High-g Accelerometer
title_fullStr Quasi-Static Calibration Method of a High-g Accelerometer
title_full_unstemmed Quasi-Static Calibration Method of a High-g Accelerometer
title_short Quasi-Static Calibration Method of a High-g Accelerometer
title_sort quasi-static calibration method of a high-g accelerometer
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5336105/
https://www.ncbi.nlm.nih.gov/pubmed/28230743
http://dx.doi.org/10.3390/s17020409
work_keys_str_mv AT wangyan quasistaticcalibrationmethodofahighgaccelerometer
AT fanjinbiao quasistaticcalibrationmethodofahighgaccelerometer
AT zujing quasistaticcalibrationmethodofahighgaccelerometer
AT xupeng quasistaticcalibrationmethodofahighgaccelerometer