Cargando…
Impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: A systematic review and meta-analysis
Contact force (CF) monitoring can be useful in accomplishing circumferential pulmonary vein (PV) isolation for atrial fibrillation (AF). This meta-analysis aimed to assess the efficacy and safety of a CF-sensing catheter in treating AF. Randomized controlled trials or non-randomized observational st...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Kare Publishing
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5336771/ https://www.ncbi.nlm.nih.gov/pubmed/28209944 http://dx.doi.org/10.14744/AnatolJCardiol.2016.7512 |
_version_ | 1782512257994850304 |
---|---|
author | Zhou, Xianhui Lv, Wenkui Zhang, Wenhui Ye, Yuanzheng Li, Yaodong Zhou, Qina Xing, Qiang Zhang, Jianghua Lu, Yanmei Zhang, Ling Wang, Hongli Qin, Wen Tang, Baopeng |
author_facet | Zhou, Xianhui Lv, Wenkui Zhang, Wenhui Ye, Yuanzheng Li, Yaodong Zhou, Qina Xing, Qiang Zhang, Jianghua Lu, Yanmei Zhang, Ling Wang, Hongli Qin, Wen Tang, Baopeng |
author_sort | Zhou, Xianhui |
collection | PubMed |
description | Contact force (CF) monitoring can be useful in accomplishing circumferential pulmonary vein (PV) isolation for atrial fibrillation (AF). This meta-analysis aimed to assess the efficacy and safety of a CF-sensing catheter in treating AF. Randomized controlled trials or non-randomized observational studies comparing AF ablation using CF-sensing or standard non-CF (NCF)-sensing catheters were identified from PubMed, EMBASE, Cochrane Library, Wanfang Data, and China National Knowledge Infrastructure (January 1, 1998–2016). A total of 19 studies were included. The primary efficacy endpoint was AF recurrence within 12 months, which significantly improved using CF-sensing catheters compared with using NCF-sensing catheters [31.1% vs. 40.5%; risk ratio (RR)=0.82; 95% confidence interval (CI), 0.73–0.93; p<0.05]. Further, the acute PV reconnection (10.1% vs. 24.2%; RR=0.45; 95% CI, 0.32–0.63; p<0.05) and incidence of major complications (1.8% vs. 3.1%; OR=0.59; 95% CI, 0.37–0.95; p<0.05) significantly improved using CF-sensing catheters compared with using NCF-sensing catheters. Procedure parameters such as procedure duration [mean difference (MD)=-28.35; 95% CI, -39.54 to -17.16; p<0.05], ablation time (MD=-3.8; 95% CI, -6.6 to -1.0; p<0.05), fluoroscopy duration (MD=-8.18; 95% CI, -14.11 to -2.24; p<0.05), and radiation dose (standard MD=-0.75; 95% CI, -1.32 to -0.18; p<0.05] significantly reduced using CF-sensing catheters. CF-sensing catheter ablation of AF can reduce the incidence of major complications and generate better outcomes compared with NCF-sensing catheters during the 12-month follow-up period. |
format | Online Article Text |
id | pubmed-5336771 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Kare Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-53367712017-06-28 Impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: A systematic review and meta-analysis Zhou, Xianhui Lv, Wenkui Zhang, Wenhui Ye, Yuanzheng Li, Yaodong Zhou, Qina Xing, Qiang Zhang, Jianghua Lu, Yanmei Zhang, Ling Wang, Hongli Qin, Wen Tang, Baopeng Anatol J Cardiol Meta Analysis Contact force (CF) monitoring can be useful in accomplishing circumferential pulmonary vein (PV) isolation for atrial fibrillation (AF). This meta-analysis aimed to assess the efficacy and safety of a CF-sensing catheter in treating AF. Randomized controlled trials or non-randomized observational studies comparing AF ablation using CF-sensing or standard non-CF (NCF)-sensing catheters were identified from PubMed, EMBASE, Cochrane Library, Wanfang Data, and China National Knowledge Infrastructure (January 1, 1998–2016). A total of 19 studies were included. The primary efficacy endpoint was AF recurrence within 12 months, which significantly improved using CF-sensing catheters compared with using NCF-sensing catheters [31.1% vs. 40.5%; risk ratio (RR)=0.82; 95% confidence interval (CI), 0.73–0.93; p<0.05]. Further, the acute PV reconnection (10.1% vs. 24.2%; RR=0.45; 95% CI, 0.32–0.63; p<0.05) and incidence of major complications (1.8% vs. 3.1%; OR=0.59; 95% CI, 0.37–0.95; p<0.05) significantly improved using CF-sensing catheters compared with using NCF-sensing catheters. Procedure parameters such as procedure duration [mean difference (MD)=-28.35; 95% CI, -39.54 to -17.16; p<0.05], ablation time (MD=-3.8; 95% CI, -6.6 to -1.0; p<0.05), fluoroscopy duration (MD=-8.18; 95% CI, -14.11 to -2.24; p<0.05), and radiation dose (standard MD=-0.75; 95% CI, -1.32 to -0.18; p<0.05] significantly reduced using CF-sensing catheters. CF-sensing catheter ablation of AF can reduce the incidence of major complications and generate better outcomes compared with NCF-sensing catheters during the 12-month follow-up period. Kare Publishing 2017-02 /pmc/articles/PMC5336771/ /pubmed/28209944 http://dx.doi.org/10.14744/AnatolJCardiol.2016.7512 Text en Copyright: © 2017 Turkish Society of Cardiology http://creativecommons.org/licenses/by-nc-sa/4.0 This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License |
spellingShingle | Meta Analysis Zhou, Xianhui Lv, Wenkui Zhang, Wenhui Ye, Yuanzheng Li, Yaodong Zhou, Qina Xing, Qiang Zhang, Jianghua Lu, Yanmei Zhang, Ling Wang, Hongli Qin, Wen Tang, Baopeng Impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: A systematic review and meta-analysis |
title | Impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: A systematic review and meta-analysis |
title_full | Impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: A systematic review and meta-analysis |
title_fullStr | Impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: A systematic review and meta-analysis |
title_full_unstemmed | Impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: A systematic review and meta-analysis |
title_short | Impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: A systematic review and meta-analysis |
title_sort | impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: a systematic review and meta-analysis |
topic | Meta Analysis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5336771/ https://www.ncbi.nlm.nih.gov/pubmed/28209944 http://dx.doi.org/10.14744/AnatolJCardiol.2016.7512 |
work_keys_str_mv | AT zhouxianhui impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis AT lvwenkui impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis AT zhangwenhui impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis AT yeyuanzheng impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis AT liyaodong impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis AT zhouqina impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis AT xingqiang impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis AT zhangjianghua impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis AT luyanmei impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis AT zhangling impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis AT wanghongli impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis AT qinwen impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis AT tangbaopeng impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis |