Cargando…

Impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: A systematic review and meta-analysis

Contact force (CF) monitoring can be useful in accomplishing circumferential pulmonary vein (PV) isolation for atrial fibrillation (AF). This meta-analysis aimed to assess the efficacy and safety of a CF-sensing catheter in treating AF. Randomized controlled trials or non-randomized observational st...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Xianhui, Lv, Wenkui, Zhang, Wenhui, Ye, Yuanzheng, Li, Yaodong, Zhou, Qina, Xing, Qiang, Zhang, Jianghua, Lu, Yanmei, Zhang, Ling, Wang, Hongli, Qin, Wen, Tang, Baopeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Kare Publishing 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5336771/
https://www.ncbi.nlm.nih.gov/pubmed/28209944
http://dx.doi.org/10.14744/AnatolJCardiol.2016.7512
_version_ 1782512257994850304
author Zhou, Xianhui
Lv, Wenkui
Zhang, Wenhui
Ye, Yuanzheng
Li, Yaodong
Zhou, Qina
Xing, Qiang
Zhang, Jianghua
Lu, Yanmei
Zhang, Ling
Wang, Hongli
Qin, Wen
Tang, Baopeng
author_facet Zhou, Xianhui
Lv, Wenkui
Zhang, Wenhui
Ye, Yuanzheng
Li, Yaodong
Zhou, Qina
Xing, Qiang
Zhang, Jianghua
Lu, Yanmei
Zhang, Ling
Wang, Hongli
Qin, Wen
Tang, Baopeng
author_sort Zhou, Xianhui
collection PubMed
description Contact force (CF) monitoring can be useful in accomplishing circumferential pulmonary vein (PV) isolation for atrial fibrillation (AF). This meta-analysis aimed to assess the efficacy and safety of a CF-sensing catheter in treating AF. Randomized controlled trials or non-randomized observational studies comparing AF ablation using CF-sensing or standard non-CF (NCF)-sensing catheters were identified from PubMed, EMBASE, Cochrane Library, Wanfang Data, and China National Knowledge Infrastructure (January 1, 1998–2016). A total of 19 studies were included. The primary efficacy endpoint was AF recurrence within 12 months, which significantly improved using CF-sensing catheters compared with using NCF-sensing catheters [31.1% vs. 40.5%; risk ratio (RR)=0.82; 95% confidence interval (CI), 0.73–0.93; p<0.05]. Further, the acute PV reconnection (10.1% vs. 24.2%; RR=0.45; 95% CI, 0.32–0.63; p<0.05) and incidence of major complications (1.8% vs. 3.1%; OR=0.59; 95% CI, 0.37–0.95; p<0.05) significantly improved using CF-sensing catheters compared with using NCF-sensing catheters. Procedure parameters such as procedure duration [mean difference (MD)=-28.35; 95% CI, -39.54 to -17.16; p<0.05], ablation time (MD=-3.8; 95% CI, -6.6 to -1.0; p<0.05), fluoroscopy duration (MD=-8.18; 95% CI, -14.11 to -2.24; p<0.05), and radiation dose (standard MD=-0.75; 95% CI, -1.32 to -0.18; p<0.05] significantly reduced using CF-sensing catheters. CF-sensing catheter ablation of AF can reduce the incidence of major complications and generate better outcomes compared with NCF-sensing catheters during the 12-month follow-up period.
format Online
Article
Text
id pubmed-5336771
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Kare Publishing
record_format MEDLINE/PubMed
spelling pubmed-53367712017-06-28 Impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: A systematic review and meta-analysis Zhou, Xianhui Lv, Wenkui Zhang, Wenhui Ye, Yuanzheng Li, Yaodong Zhou, Qina Xing, Qiang Zhang, Jianghua Lu, Yanmei Zhang, Ling Wang, Hongli Qin, Wen Tang, Baopeng Anatol J Cardiol Meta Analysis Contact force (CF) monitoring can be useful in accomplishing circumferential pulmonary vein (PV) isolation for atrial fibrillation (AF). This meta-analysis aimed to assess the efficacy and safety of a CF-sensing catheter in treating AF. Randomized controlled trials or non-randomized observational studies comparing AF ablation using CF-sensing or standard non-CF (NCF)-sensing catheters were identified from PubMed, EMBASE, Cochrane Library, Wanfang Data, and China National Knowledge Infrastructure (January 1, 1998–2016). A total of 19 studies were included. The primary efficacy endpoint was AF recurrence within 12 months, which significantly improved using CF-sensing catheters compared with using NCF-sensing catheters [31.1% vs. 40.5%; risk ratio (RR)=0.82; 95% confidence interval (CI), 0.73–0.93; p<0.05]. Further, the acute PV reconnection (10.1% vs. 24.2%; RR=0.45; 95% CI, 0.32–0.63; p<0.05) and incidence of major complications (1.8% vs. 3.1%; OR=0.59; 95% CI, 0.37–0.95; p<0.05) significantly improved using CF-sensing catheters compared with using NCF-sensing catheters. Procedure parameters such as procedure duration [mean difference (MD)=-28.35; 95% CI, -39.54 to -17.16; p<0.05], ablation time (MD=-3.8; 95% CI, -6.6 to -1.0; p<0.05), fluoroscopy duration (MD=-8.18; 95% CI, -14.11 to -2.24; p<0.05), and radiation dose (standard MD=-0.75; 95% CI, -1.32 to -0.18; p<0.05] significantly reduced using CF-sensing catheters. CF-sensing catheter ablation of AF can reduce the incidence of major complications and generate better outcomes compared with NCF-sensing catheters during the 12-month follow-up period. Kare Publishing 2017-02 /pmc/articles/PMC5336771/ /pubmed/28209944 http://dx.doi.org/10.14744/AnatolJCardiol.2016.7512 Text en Copyright: © 2017 Turkish Society of Cardiology http://creativecommons.org/licenses/by-nc-sa/4.0 This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License
spellingShingle Meta Analysis
Zhou, Xianhui
Lv, Wenkui
Zhang, Wenhui
Ye, Yuanzheng
Li, Yaodong
Zhou, Qina
Xing, Qiang
Zhang, Jianghua
Lu, Yanmei
Zhang, Ling
Wang, Hongli
Qin, Wen
Tang, Baopeng
Impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: A systematic review and meta-analysis
title Impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: A systematic review and meta-analysis
title_full Impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: A systematic review and meta-analysis
title_fullStr Impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: A systematic review and meta-analysis
title_full_unstemmed Impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: A systematic review and meta-analysis
title_short Impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: A systematic review and meta-analysis
title_sort impact of contact force technology on reducing the recurrence and major complications of atrial fibrillation ablation: a systematic review and meta-analysis
topic Meta Analysis
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5336771/
https://www.ncbi.nlm.nih.gov/pubmed/28209944
http://dx.doi.org/10.14744/AnatolJCardiol.2016.7512
work_keys_str_mv AT zhouxianhui impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis
AT lvwenkui impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis
AT zhangwenhui impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis
AT yeyuanzheng impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis
AT liyaodong impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis
AT zhouqina impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis
AT xingqiang impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis
AT zhangjianghua impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis
AT luyanmei impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis
AT zhangling impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis
AT wanghongli impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis
AT qinwen impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis
AT tangbaopeng impactofcontactforcetechnologyonreducingtherecurrenceandmajorcomplicationsofatrialfibrillationablationasystematicreviewandmetaanalysis