Quantifying Variability in Longitudinal Peripapillary RNFL and Choroidal Layer Thickness Using Surface Based Registration of OCT Images

PURPOSE: To assess within-subject variability of retinal nerve fiber layer (RNFL) and choroidal layer thickness in longitudinal repeat optical coherence tomography (OCT) images with point-to-point measurement comparison made using nonrigid surface registration. METHODS: Nine repeat peripapillary OCT...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Sieun, Heisler, Morgan, Mackenzie, Paul J., Sarunic, Marinko V., Beg, Mirza Faisal
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5338475/
https://www.ncbi.nlm.nih.gov/pubmed/28275526
http://dx.doi.org/10.1167/tvst.6.1.11
_version_ 1782512539028946944
author Lee, Sieun
Heisler, Morgan
Mackenzie, Paul J.
Sarunic, Marinko V.
Beg, Mirza Faisal
author_facet Lee, Sieun
Heisler, Morgan
Mackenzie, Paul J.
Sarunic, Marinko V.
Beg, Mirza Faisal
author_sort Lee, Sieun
collection PubMed
description PURPOSE: To assess within-subject variability of retinal nerve fiber layer (RNFL) and choroidal layer thickness in longitudinal repeat optical coherence tomography (OCT) images with point-to-point measurement comparison made using nonrigid surface registration. METHODS: Nine repeat peripapillary OCT images were acquired over 3 weeks from 12 eyes of 6 young, healthy subjects using a 1060-nm prototype swept-source device. The RNFL, choroid and the Bruch's membrane opening (BMO) were segmented, and point-wise layer thicknesses and BMO dimensions were measured. For each eye, the layer surfaces of eight follow-up images were registered to those of the baseline image, first by rigid alignment using blood vessel projections and axial height and tilt correction, followed by nonrigid registration of currents-based diffeomorphisms algorithms. This mapped all follow-up measurements point-wise to the common baseline coordinate system, allowing for point-wise statistical analysis. Measurement variability was evaluated point-wise for layer thicknesses and BMO dimensions by time-standard deviation (tSD). RESULTS: The intraclass correlation coefficients (ICCs) of BMO area and eccentricity were 0.993 and 0.972, respectively. Time-mean and tSD were computed point-wise for RNFL and choroidal thickness and color-mapped on the baseline surfaces. tSD was less than two coherence lengths of the system 2ℓ = 12 μm at most vertices. High RNFL thickness variability corresponded to the locations of retinal vessels, and choroidal thickness varied more than RNFL thickness. CONCLUSIONS: Our registration-based end-to-end pipeline produced point-wise correspondence among time-series retinal and choroidal surfaces with high measurement repeatability (low variability). Blood vessels were found to be the main sources contributing to the normal variability of the RNFL thickness measure. The computational pipeline with a measurement of normal variability can be used in future longitudinal studies to identify changes that are above the threshold of normal point-wise variability and track localized changes in retinal layers in high spatial resolution. TRANSLATIONAL RELEVANCE: Using the registration-based approach presented in this study, longitudinal changes in retinal and choroidal layers can be detected with higher sensitivity and spatial precision.
format Online
Article
Text
id pubmed-5338475
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-53384752017-03-08 Quantifying Variability in Longitudinal Peripapillary RNFL and Choroidal Layer Thickness Using Surface Based Registration of OCT Images Lee, Sieun Heisler, Morgan Mackenzie, Paul J. Sarunic, Marinko V. Beg, Mirza Faisal Transl Vis Sci Technol Articles PURPOSE: To assess within-subject variability of retinal nerve fiber layer (RNFL) and choroidal layer thickness in longitudinal repeat optical coherence tomography (OCT) images with point-to-point measurement comparison made using nonrigid surface registration. METHODS: Nine repeat peripapillary OCT images were acquired over 3 weeks from 12 eyes of 6 young, healthy subjects using a 1060-nm prototype swept-source device. The RNFL, choroid and the Bruch's membrane opening (BMO) were segmented, and point-wise layer thicknesses and BMO dimensions were measured. For each eye, the layer surfaces of eight follow-up images were registered to those of the baseline image, first by rigid alignment using blood vessel projections and axial height and tilt correction, followed by nonrigid registration of currents-based diffeomorphisms algorithms. This mapped all follow-up measurements point-wise to the common baseline coordinate system, allowing for point-wise statistical analysis. Measurement variability was evaluated point-wise for layer thicknesses and BMO dimensions by time-standard deviation (tSD). RESULTS: The intraclass correlation coefficients (ICCs) of BMO area and eccentricity were 0.993 and 0.972, respectively. Time-mean and tSD were computed point-wise for RNFL and choroidal thickness and color-mapped on the baseline surfaces. tSD was less than two coherence lengths of the system 2ℓ = 12 μm at most vertices. High RNFL thickness variability corresponded to the locations of retinal vessels, and choroidal thickness varied more than RNFL thickness. CONCLUSIONS: Our registration-based end-to-end pipeline produced point-wise correspondence among time-series retinal and choroidal surfaces with high measurement repeatability (low variability). Blood vessels were found to be the main sources contributing to the normal variability of the RNFL thickness measure. The computational pipeline with a measurement of normal variability can be used in future longitudinal studies to identify changes that are above the threshold of normal point-wise variability and track localized changes in retinal layers in high spatial resolution. TRANSLATIONAL RELEVANCE: Using the registration-based approach presented in this study, longitudinal changes in retinal and choroidal layers can be detected with higher sensitivity and spatial precision. The Association for Research in Vision and Ophthalmology 2017-02-28 /pmc/articles/PMC5338475/ /pubmed/28275526 http://dx.doi.org/10.1167/tvst.6.1.11 Text en Copyright 2017 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Articles
Lee, Sieun
Heisler, Morgan
Mackenzie, Paul J.
Sarunic, Marinko V.
Beg, Mirza Faisal
Quantifying Variability in Longitudinal Peripapillary RNFL and Choroidal Layer Thickness Using Surface Based Registration of OCT Images
title Quantifying Variability in Longitudinal Peripapillary RNFL and Choroidal Layer Thickness Using Surface Based Registration of OCT Images
title_full Quantifying Variability in Longitudinal Peripapillary RNFL and Choroidal Layer Thickness Using Surface Based Registration of OCT Images
title_fullStr Quantifying Variability in Longitudinal Peripapillary RNFL and Choroidal Layer Thickness Using Surface Based Registration of OCT Images
title_full_unstemmed Quantifying Variability in Longitudinal Peripapillary RNFL and Choroidal Layer Thickness Using Surface Based Registration of OCT Images
title_short Quantifying Variability in Longitudinal Peripapillary RNFL and Choroidal Layer Thickness Using Surface Based Registration of OCT Images
title_sort quantifying variability in longitudinal peripapillary rnfl and choroidal layer thickness using surface based registration of oct images
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5338475/
https://www.ncbi.nlm.nih.gov/pubmed/28275526
http://dx.doi.org/10.1167/tvst.6.1.11
work_keys_str_mv AT leesieun quantifyingvariabilityinlongitudinalperipapillaryrnflandchoroidallayerthicknessusingsurfacebasedregistrationofoctimages
AT heislermorgan quantifyingvariabilityinlongitudinalperipapillaryrnflandchoroidallayerthicknessusingsurfacebasedregistrationofoctimages
AT mackenziepaulj quantifyingvariabilityinlongitudinalperipapillaryrnflandchoroidallayerthicknessusingsurfacebasedregistrationofoctimages
AT sarunicmarinkov quantifyingvariabilityinlongitudinalperipapillaryrnflandchoroidallayerthicknessusingsurfacebasedregistrationofoctimages
AT begmirzafaisal quantifyingvariabilityinlongitudinalperipapillaryrnflandchoroidallayerthicknessusingsurfacebasedregistrationofoctimages