Cargando…
Comparison of the QIAGEN artus HBV QS-RGQ Assay With the Roche COBAS AmpliPrep/COBAS TaqMan HBV Assay for Quantifying Viral DNA in Sera of Chronic Hepatitis B Patients
BACKGROUND: Hepatitis B virus DNA quantification is essential for managing chronic hepatitis B (CHB). We compared the performance of artus HBV QS-RGQ (QIAGEN GmbH, Germany) and CAP/CTM v2.0 HBV assays (Roche Molecular Diagnostics, USA) in CHB patients. METHODS: A comparative evaluation between two a...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Laboratory Medicine
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5339097/ https://www.ncbi.nlm.nih.gov/pubmed/28224771 http://dx.doi.org/10.3343/alm.2017.37.3.248 |
_version_ | 1782512610612084736 |
---|---|
author | Han, Mi-Soon Park, Yongjung Nah, Hyunjin Kim, Hyon-Suk |
author_facet | Han, Mi-Soon Park, Yongjung Nah, Hyunjin Kim, Hyon-Suk |
author_sort | Han, Mi-Soon |
collection | PubMed |
description | BACKGROUND: Hepatitis B virus DNA quantification is essential for managing chronic hepatitis B (CHB). We compared the performance of artus HBV QS-RGQ (QIAGEN GmbH, Germany) and CAP/CTM v2.0 HBV assays (Roche Molecular Diagnostics, USA) in CHB patients. METHODS: A comparative evaluation between two assays was performed with 508 clinical serum samples. Precision, linearity, and the limit of detection (LOD) of QS-RGQ assay was evaluated by using the WHO standard 97/750 and clinical samples. RESULTS: Detection rates and viral loads as determined QS-RGQ assay were significantly lower than those from the CAP/CTM v2.0 assay (52.8% vs 60.6%; 3.55±1.77 IU/mL vs 4.18±1.89 IU/mL, P<0.0001). The kappa coefficient between qualitative results was 0.79 (95% confidence interval, 0.74 to 0.85). Bland-Altman plot found a mean difference of (QS-RGQ − CAP/CTM v2.0)=−0.63 log(10) IU/mL (95% limit of agreement, −1.48 to 0.22). Repeatability and total imprecision (% CV) of the QS-RGQ assay were 1.0% and 1.1% at 2,000 IU/mL, and 0.7% and 1.4% at 20,000 IU/mL, respectively. Linearity of this assay ranged from 31.6 to 1.0±10(7) IU/mL, and the LOD was 2.95 IU/mL. CONCLUSIONS: The artus HBV QS-RGQ assay showed good performance but significantly decreased detection rate and viral load compared with CAP/CTM v2.0 assays. This assay recommends using plasma; however, we used stored serum because of the retrospective study design. Usually HBV DNA quantification is performed in plasma or serum, but sample type and clinical relevance of quantitative values should be considered when determining the clinical application of this reagent. |
format | Online Article Text |
id | pubmed-5339097 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | The Korean Society for Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-53390972017-05-01 Comparison of the QIAGEN artus HBV QS-RGQ Assay With the Roche COBAS AmpliPrep/COBAS TaqMan HBV Assay for Quantifying Viral DNA in Sera of Chronic Hepatitis B Patients Han, Mi-Soon Park, Yongjung Nah, Hyunjin Kim, Hyon-Suk Ann Lab Med Original Article BACKGROUND: Hepatitis B virus DNA quantification is essential for managing chronic hepatitis B (CHB). We compared the performance of artus HBV QS-RGQ (QIAGEN GmbH, Germany) and CAP/CTM v2.0 HBV assays (Roche Molecular Diagnostics, USA) in CHB patients. METHODS: A comparative evaluation between two assays was performed with 508 clinical serum samples. Precision, linearity, and the limit of detection (LOD) of QS-RGQ assay was evaluated by using the WHO standard 97/750 and clinical samples. RESULTS: Detection rates and viral loads as determined QS-RGQ assay were significantly lower than those from the CAP/CTM v2.0 assay (52.8% vs 60.6%; 3.55±1.77 IU/mL vs 4.18±1.89 IU/mL, P<0.0001). The kappa coefficient between qualitative results was 0.79 (95% confidence interval, 0.74 to 0.85). Bland-Altman plot found a mean difference of (QS-RGQ − CAP/CTM v2.0)=−0.63 log(10) IU/mL (95% limit of agreement, −1.48 to 0.22). Repeatability and total imprecision (% CV) of the QS-RGQ assay were 1.0% and 1.1% at 2,000 IU/mL, and 0.7% and 1.4% at 20,000 IU/mL, respectively. Linearity of this assay ranged from 31.6 to 1.0±10(7) IU/mL, and the LOD was 2.95 IU/mL. CONCLUSIONS: The artus HBV QS-RGQ assay showed good performance but significantly decreased detection rate and viral load compared with CAP/CTM v2.0 assays. This assay recommends using plasma; however, we used stored serum because of the retrospective study design. Usually HBV DNA quantification is performed in plasma or serum, but sample type and clinical relevance of quantitative values should be considered when determining the clinical application of this reagent. The Korean Society for Laboratory Medicine 2017-05 2017-02-17 /pmc/articles/PMC5339097/ /pubmed/28224771 http://dx.doi.org/10.3343/alm.2017.37.3.248 Text en © The Korean Society for Laboratory Medicine http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Han, Mi-Soon Park, Yongjung Nah, Hyunjin Kim, Hyon-Suk Comparison of the QIAGEN artus HBV QS-RGQ Assay With the Roche COBAS AmpliPrep/COBAS TaqMan HBV Assay for Quantifying Viral DNA in Sera of Chronic Hepatitis B Patients |
title | Comparison of the QIAGEN artus HBV QS-RGQ Assay With the Roche COBAS AmpliPrep/COBAS TaqMan HBV Assay for Quantifying Viral DNA in Sera of Chronic Hepatitis B Patients |
title_full | Comparison of the QIAGEN artus HBV QS-RGQ Assay With the Roche COBAS AmpliPrep/COBAS TaqMan HBV Assay for Quantifying Viral DNA in Sera of Chronic Hepatitis B Patients |
title_fullStr | Comparison of the QIAGEN artus HBV QS-RGQ Assay With the Roche COBAS AmpliPrep/COBAS TaqMan HBV Assay for Quantifying Viral DNA in Sera of Chronic Hepatitis B Patients |
title_full_unstemmed | Comparison of the QIAGEN artus HBV QS-RGQ Assay With the Roche COBAS AmpliPrep/COBAS TaqMan HBV Assay for Quantifying Viral DNA in Sera of Chronic Hepatitis B Patients |
title_short | Comparison of the QIAGEN artus HBV QS-RGQ Assay With the Roche COBAS AmpliPrep/COBAS TaqMan HBV Assay for Quantifying Viral DNA in Sera of Chronic Hepatitis B Patients |
title_sort | comparison of the qiagen artus hbv qs-rgq assay with the roche cobas ampliprep/cobas taqman hbv assay for quantifying viral dna in sera of chronic hepatitis b patients |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5339097/ https://www.ncbi.nlm.nih.gov/pubmed/28224771 http://dx.doi.org/10.3343/alm.2017.37.3.248 |
work_keys_str_mv | AT hanmisoon comparisonoftheqiagenartushbvqsrgqassaywiththerochecobasampliprepcobastaqmanhbvassayforquantifyingviraldnainseraofchronichepatitisbpatients AT parkyongjung comparisonoftheqiagenartushbvqsrgqassaywiththerochecobasampliprepcobastaqmanhbvassayforquantifyingviraldnainseraofchronichepatitisbpatients AT nahhyunjin comparisonoftheqiagenartushbvqsrgqassaywiththerochecobasampliprepcobastaqmanhbvassayforquantifyingviraldnainseraofchronichepatitisbpatients AT kimhyonsuk comparisonoftheqiagenartushbvqsrgqassaywiththerochecobasampliprepcobastaqmanhbvassayforquantifyingviraldnainseraofchronichepatitisbpatients |