Cargando…

Investigating Cardiac Motion Patterns Using Synthetic High-Resolution 3D Cardiovascular Magnetic Resonance Images and Statistical Shape Analysis

Diagnosis of ventricular dysfunction in congenital heart disease is more and more based on medical imaging, which allows investigation of abnormal cardiac morphology and correlated abnormal function. Although analysis of 2D images represents the clinical standard, novel tools performing automatic pr...

Descripción completa

Detalles Bibliográficos
Autores principales: Biffi, Benedetta, Bruse, Jan L., Zuluaga, Maria A., Ntsinjana, Hopewell N., Taylor, Andrew M., Schievano, Silvia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5340748/
https://www.ncbi.nlm.nih.gov/pubmed/28337429
http://dx.doi.org/10.3389/fped.2017.00034
_version_ 1782512859197997056
author Biffi, Benedetta
Bruse, Jan L.
Zuluaga, Maria A.
Ntsinjana, Hopewell N.
Taylor, Andrew M.
Schievano, Silvia
author_facet Biffi, Benedetta
Bruse, Jan L.
Zuluaga, Maria A.
Ntsinjana, Hopewell N.
Taylor, Andrew M.
Schievano, Silvia
author_sort Biffi, Benedetta
collection PubMed
description Diagnosis of ventricular dysfunction in congenital heart disease is more and more based on medical imaging, which allows investigation of abnormal cardiac morphology and correlated abnormal function. Although analysis of 2D images represents the clinical standard, novel tools performing automatic processing of 3D images are becoming available, providing more detailed and comprehensive information than simple 2D morphometry. Among these, statistical shape analysis (SSA) allows a consistent and quantitative description of a population of complex shapes, as a way to detect novel biomarkers, ultimately improving diagnosis and pathology understanding. The aim of this study is to describe the implementation of a SSA method for the investigation of 3D left ventricular shape and motion patterns and to test it on a small sample of 4 congenital repaired aortic stenosis patients and 4 age-matched healthy volunteers to demonstrate its potential. The advantage of this method is the capability of analyzing subject-specific motion patterns separately from the individual morphology, visually and quantitatively, as a way to identify functional abnormalities related to both dynamics and shape. Specifically, we combined 3D, high-resolution whole heart data with 2D, temporal information provided by cine cardiovascular magnetic resonance images, and we used an SSA approach to analyze 3D motion per se. Preliminary results of this pilot study showed that using this method, some differences in end-diastolic and end-systolic ventricular shapes could be captured, but it was not possible to clearly separate the two cohorts based on shape information alone. However, further analyses on ventricular motion allowed to qualitatively identify differences between the two populations. Moreover, by describing shape and motion with a small number of principal components, this method offers a fully automated process to obtain visually intuitive and numerical information on cardiac shape and motion, which could be, once validated on a larger sample size, easily integrated into the clinical workflow. To conclude, in this preliminary work, we have implemented state-of-the-art automatic segmentation and SSA methods, and we have shown how they could improve our understanding of ventricular kinetics by visually and potentially quantitatively highlighting aspects that are usually not picked up by traditional approaches.
format Online
Article
Text
id pubmed-5340748
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-53407482017-03-23 Investigating Cardiac Motion Patterns Using Synthetic High-Resolution 3D Cardiovascular Magnetic Resonance Images and Statistical Shape Analysis Biffi, Benedetta Bruse, Jan L. Zuluaga, Maria A. Ntsinjana, Hopewell N. Taylor, Andrew M. Schievano, Silvia Front Pediatr Pediatrics Diagnosis of ventricular dysfunction in congenital heart disease is more and more based on medical imaging, which allows investigation of abnormal cardiac morphology and correlated abnormal function. Although analysis of 2D images represents the clinical standard, novel tools performing automatic processing of 3D images are becoming available, providing more detailed and comprehensive information than simple 2D morphometry. Among these, statistical shape analysis (SSA) allows a consistent and quantitative description of a population of complex shapes, as a way to detect novel biomarkers, ultimately improving diagnosis and pathology understanding. The aim of this study is to describe the implementation of a SSA method for the investigation of 3D left ventricular shape and motion patterns and to test it on a small sample of 4 congenital repaired aortic stenosis patients and 4 age-matched healthy volunteers to demonstrate its potential. The advantage of this method is the capability of analyzing subject-specific motion patterns separately from the individual morphology, visually and quantitatively, as a way to identify functional abnormalities related to both dynamics and shape. Specifically, we combined 3D, high-resolution whole heart data with 2D, temporal information provided by cine cardiovascular magnetic resonance images, and we used an SSA approach to analyze 3D motion per se. Preliminary results of this pilot study showed that using this method, some differences in end-diastolic and end-systolic ventricular shapes could be captured, but it was not possible to clearly separate the two cohorts based on shape information alone. However, further analyses on ventricular motion allowed to qualitatively identify differences between the two populations. Moreover, by describing shape and motion with a small number of principal components, this method offers a fully automated process to obtain visually intuitive and numerical information on cardiac shape and motion, which could be, once validated on a larger sample size, easily integrated into the clinical workflow. To conclude, in this preliminary work, we have implemented state-of-the-art automatic segmentation and SSA methods, and we have shown how they could improve our understanding of ventricular kinetics by visually and potentially quantitatively highlighting aspects that are usually not picked up by traditional approaches. Frontiers Media S.A. 2017-03-08 /pmc/articles/PMC5340748/ /pubmed/28337429 http://dx.doi.org/10.3389/fped.2017.00034 Text en Copyright © 2017 Biffi, Bruse, Zuluaga, Ntsinjana, Taylor and Schievano. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Pediatrics
Biffi, Benedetta
Bruse, Jan L.
Zuluaga, Maria A.
Ntsinjana, Hopewell N.
Taylor, Andrew M.
Schievano, Silvia
Investigating Cardiac Motion Patterns Using Synthetic High-Resolution 3D Cardiovascular Magnetic Resonance Images and Statistical Shape Analysis
title Investigating Cardiac Motion Patterns Using Synthetic High-Resolution 3D Cardiovascular Magnetic Resonance Images and Statistical Shape Analysis
title_full Investigating Cardiac Motion Patterns Using Synthetic High-Resolution 3D Cardiovascular Magnetic Resonance Images and Statistical Shape Analysis
title_fullStr Investigating Cardiac Motion Patterns Using Synthetic High-Resolution 3D Cardiovascular Magnetic Resonance Images and Statistical Shape Analysis
title_full_unstemmed Investigating Cardiac Motion Patterns Using Synthetic High-Resolution 3D Cardiovascular Magnetic Resonance Images and Statistical Shape Analysis
title_short Investigating Cardiac Motion Patterns Using Synthetic High-Resolution 3D Cardiovascular Magnetic Resonance Images and Statistical Shape Analysis
title_sort investigating cardiac motion patterns using synthetic high-resolution 3d cardiovascular magnetic resonance images and statistical shape analysis
topic Pediatrics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5340748/
https://www.ncbi.nlm.nih.gov/pubmed/28337429
http://dx.doi.org/10.3389/fped.2017.00034
work_keys_str_mv AT biffibenedetta investigatingcardiacmotionpatternsusingsynthetichighresolution3dcardiovascularmagneticresonanceimagesandstatisticalshapeanalysis
AT brusejanl investigatingcardiacmotionpatternsusingsynthetichighresolution3dcardiovascularmagneticresonanceimagesandstatisticalshapeanalysis
AT zuluagamariaa investigatingcardiacmotionpatternsusingsynthetichighresolution3dcardiovascularmagneticresonanceimagesandstatisticalshapeanalysis
AT ntsinjanahopewelln investigatingcardiacmotionpatternsusingsynthetichighresolution3dcardiovascularmagneticresonanceimagesandstatisticalshapeanalysis
AT taylorandrewm investigatingcardiacmotionpatternsusingsynthetichighresolution3dcardiovascularmagneticresonanceimagesandstatisticalshapeanalysis
AT schievanosilvia investigatingcardiacmotionpatternsusingsynthetichighresolution3dcardiovascularmagneticresonanceimagesandstatisticalshapeanalysis