INTRODUCTION: Left ventricular assist device (LVAD) implantation is a viable therapy for patients with severe end-stage heart failure, providing effective haemodynamic support and improved quality of life. The Heart Assist 5 (Micromed Cardiovascular Inc, Houston, TX) continuous-flow LVAD has been on...

Descripción completa

Detalles Bibliográficos
Autores principales: Demirozu, Zumrut Tuba, Kucukaksu, Deniz Suha, Arat, Nurcan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Clinics Cardive Publishing 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5340905/
https://www.ncbi.nlm.nih.gov/pubmed/27841907
http://dx.doi.org/10.5830/CVJA-2015-083
_version_ 1782512892795420672
author Demirozu, Zumrut Tuba
Kucukaksu, Deniz Suha
Arat, Nurcan
author_facet Demirozu, Zumrut Tuba
Kucukaksu, Deniz Suha
Arat, Nurcan
author_sort Demirozu, Zumrut Tuba
collection PubMed
description INTRODUCTION: Left ventricular assist device (LVAD) implantation is a viable therapy for patients with severe end-stage heart failure, providing effective haemodynamic support and improved quality of life. The Heart Assist 5 (Micromed Cardiovascular Inc, Houston, TX) continuous-flow LVAD has been on the market in Europe since May 2009. METHODS: We evaluated nine Heart Assist 5 LVAD patients with two- and three-dimensional transthoracic echocardiographic (TTE) and transoesophageal echocardiographic (TEE) parameters between December 2011 and December 2013. The pre-operative TTE LVAD evaluations included left ventricular (LV) function and structure, quantification of right ventricular (RV) function and tricuspid regurgitation (TR), assessment of aortic and mitral regurgitation, and presence of patent foramen ovale and intra-cardiac clots. Peri-operative TEE determined the inflow cannula and septum position, and assessed the de-airing process while weaning from cardiopulmonary bypass. Post-operative serial follow-up TTE showed the surgical results of LVAD implantation, determined the overall structure and function of the LV, RV and TR, and observed the inflow and outflow cannula position. RESULTS: Nine patients who had undergone Heart Assist 5 LVAD implantation and had been followed up for more than 30 days were included in this study. Eight patients had ischaemic cardiomyopathy and one had adriamycin-induced cardiomyopathy. Pre-implantation data: the mean age of the patients was 52 ± 13 (34–64) years, mean body surface area (BSA) was 1.8 ± 0.2 (1.6–2.0) m2, mean cardiac index (CI) was 2.04 ± 0.4 (1.5–2.6) l/min/m2, mean cardiac output (CO) was 3.7 ± 0.7 (2.6–4.2) l/min, mean ejection fraction (EF) was 23 ± 5 (18–28)%, and right ventricular fractional area contraction (RVFAC) was 43 ± 9 (35–55)%. One patient had aortic valve replacement (AVR) during the LVAD implantation, and excess current alarms and increased power were suspected to be caused by a possible thrombus. Close follow up with TTE studies were carried out to clear the LV of thrombus formation, and the inflow cannula position was checked to maintain the septum in the midline, so preventing the suction cascade. Four patients were followed up for more than two years, and two were followed up for more than a year. Three patients died due to multi-organ failure. Follow-up speed-change TTE studies of six patients showed that the mean speed was 9 800 ± 600 (9 500–10 400) rpm, and mean CO was 4.7 ± 0.3 (4.3– 5.0) l/min during the three-month post-implant period. CONCLUSION: We believe that TTE can play a major role in managing LVAD patients to achieve optimal settings for each patient. A large series is mandatory for assessment of echocardiographic studies on Heart Assist 5 LVAD.
format Online
Article
Text
id pubmed-5340905
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Clinics Cardive Publishing
record_format MEDLINE/PubMed
spelling pubmed-53409052017-03-16 Fine-tuning management of the Heart Assist 5 left ventricular assist device with two- and three-dimensional echocardiography Demirozu, Zumrut Tuba Kucukaksu, Deniz Suha Arat, Nurcan Cardiovasc J Afr Cardiovascular Topics INTRODUCTION: Left ventricular assist device (LVAD) implantation is a viable therapy for patients with severe end-stage heart failure, providing effective haemodynamic support and improved quality of life. The Heart Assist 5 (Micromed Cardiovascular Inc, Houston, TX) continuous-flow LVAD has been on the market in Europe since May 2009. METHODS: We evaluated nine Heart Assist 5 LVAD patients with two- and three-dimensional transthoracic echocardiographic (TTE) and transoesophageal echocardiographic (TEE) parameters between December 2011 and December 2013. The pre-operative TTE LVAD evaluations included left ventricular (LV) function and structure, quantification of right ventricular (RV) function and tricuspid regurgitation (TR), assessment of aortic and mitral regurgitation, and presence of patent foramen ovale and intra-cardiac clots. Peri-operative TEE determined the inflow cannula and septum position, and assessed the de-airing process while weaning from cardiopulmonary bypass. Post-operative serial follow-up TTE showed the surgical results of LVAD implantation, determined the overall structure and function of the LV, RV and TR, and observed the inflow and outflow cannula position. RESULTS: Nine patients who had undergone Heart Assist 5 LVAD implantation and had been followed up for more than 30 days were included in this study. Eight patients had ischaemic cardiomyopathy and one had adriamycin-induced cardiomyopathy. Pre-implantation data: the mean age of the patients was 52 ± 13 (34–64) years, mean body surface area (BSA) was 1.8 ± 0.2 (1.6–2.0) m2, mean cardiac index (CI) was 2.04 ± 0.4 (1.5–2.6) l/min/m2, mean cardiac output (CO) was 3.7 ± 0.7 (2.6–4.2) l/min, mean ejection fraction (EF) was 23 ± 5 (18–28)%, and right ventricular fractional area contraction (RVFAC) was 43 ± 9 (35–55)%. One patient had aortic valve replacement (AVR) during the LVAD implantation, and excess current alarms and increased power were suspected to be caused by a possible thrombus. Close follow up with TTE studies were carried out to clear the LV of thrombus formation, and the inflow cannula position was checked to maintain the septum in the midline, so preventing the suction cascade. Four patients were followed up for more than two years, and two were followed up for more than a year. Three patients died due to multi-organ failure. Follow-up speed-change TTE studies of six patients showed that the mean speed was 9 800 ± 600 (9 500–10 400) rpm, and mean CO was 4.7 ± 0.3 (4.3– 5.0) l/min during the three-month post-implant period. CONCLUSION: We believe that TTE can play a major role in managing LVAD patients to achieve optimal settings for each patient. A large series is mandatory for assessment of echocardiographic studies on Heart Assist 5 LVAD. Clinics Cardive Publishing 2016 /pmc/articles/PMC5340905/ /pubmed/27841907 http://dx.doi.org/10.5830/CVJA-2015-083 Text en Copyright © 2015 Clinics Cardive Publishing http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Cardiovascular Topics
Demirozu, Zumrut Tuba
Kucukaksu, Deniz Suha
Arat, Nurcan
Fine-tuning management of the Heart Assist 5 left ventricular assist device with two- and three-dimensional echocardiography
title Fine-tuning management of the Heart Assist 5 left ventricular assist device with two- and three-dimensional echocardiography
title_full Fine-tuning management of the Heart Assist 5 left ventricular assist device with two- and three-dimensional echocardiography
title_fullStr Fine-tuning management of the Heart Assist 5 left ventricular assist device with two- and three-dimensional echocardiography
title_full_unstemmed Fine-tuning management of the Heart Assist 5 left ventricular assist device with two- and three-dimensional echocardiography
title_short Fine-tuning management of the Heart Assist 5 left ventricular assist device with two- and three-dimensional echocardiography
title_sort fine-tuning management of the heart assist 5 left ventricular assist device with two- and three-dimensional echocardiography
topic Cardiovascular Topics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5340905/
https://www.ncbi.nlm.nih.gov/pubmed/27841907
http://dx.doi.org/10.5830/CVJA-2015-083
work_keys_str_mv AT demirozuzumruttuba finetuningmanagementoftheheartassist5leftventricularassistdevicewithtwoandthreedimensionalechocardiography
AT kucukaksudenizsuha finetuningmanagementoftheheartassist5leftventricularassistdevicewithtwoandthreedimensionalechocardiography
AT aratnurcan finetuningmanagementoftheheartassist5leftventricularassistdevicewithtwoandthreedimensionalechocardiography