Isobio software: biological dose distribution and biological dose volume histogram from physical dose conversion using linear-quadratic-linear model

PURPOSE: To develop an in-house software program that is able to calculate and generate the biological dose distribution and biological dose volume histogram by physical dose conversion using the linear-quadratic-linear (LQL) model. MATERIAL AND METHODS: The Isobio software was developed using MATLA...

Descripción completa

Detalles Bibliográficos
Autores principales: Jaikuna, Tanwiwat, Khadsiri, Phatchareewan, Chawapun, Nisa, Saekho, Suwit, Tharavichitkul, Ekkasit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5346611/
https://www.ncbi.nlm.nih.gov/pubmed/28344603
http://dx.doi.org/10.5114/jcb.2017.66082
Descripción
Sumario:PURPOSE: To develop an in-house software program that is able to calculate and generate the biological dose distribution and biological dose volume histogram by physical dose conversion using the linear-quadratic-linear (LQL) model. MATERIAL AND METHODS: The Isobio software was developed using MATLAB version 2014b to calculate and generate the biological dose distribution and biological dose volume histograms. The physical dose from each voxel in treatment planning was extracted through Computational Environment for Radiotherapy Research (CERR), and the accuracy was verified by the differentiation between the dose volume histogram from CERR and the treatment planning system. An equivalent dose in 2 Gy fraction (EQD(2)) was calculated using biological effective dose (BED) based on the LQL model. The software calculation and the manual calculation were compared for EQD(2) verification with pair t-test statistical analysis using IBM SPSS Statistics version 22 (64-bit). RESULTS: Two and three-dimensional biological dose distribution and biological dose volume histogram were displayed correctly by the Isobio software. Different physical doses were found between CERR and treatment planning system (TPS) in Oncentra, with 3.33% in high-risk clinical target volume (HR-CTV) determined by D(90%), 0.56% in the bladder, 1.74% in the rectum when determined by D(2cc), and less than 1% in Pinnacle. The difference in the EQD(2) between the software calculation and the manual calculation was not significantly different with 0.00% at p-values 0.820, 0.095, and 0.593 for external beam radiation therapy (EBRT) and 0.240, 0.320, and 0.849 for brachytherapy (BT) in HR-CTV, bladder, and rectum, respectively. CONCLUSIONS: The Isobio software is a feasible tool to generate the biological dose distribution and biological dose volume histogram for treatment plan evaluation in both EBRT and BT.