Cargando…

Tidal breathing parameters measured using structured light plethysmography in healthy children and those with asthma before and after bronchodilator

Structured light plethysmography (SLP) is a light‐based, noncontact technique that measures tidal breathing by monitoring displacements of the thoracoabdominal (TA) wall. We used SLP to measure tidal breathing parameters and their within‐subject variability (v) in 30 children aged 7–16 years with as...

Descripción completa

Detalles Bibliográficos
Autores principales: Hmeidi, Hamzah, Motamedi‐Fakhr, Shayan, Chadwick, Edward, Gilchrist, Francis J., Lenney, Warren, Iles, Richard, Wilson, Rachel C., Alexander, John
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5350176/
https://www.ncbi.nlm.nih.gov/pubmed/28275111
http://dx.doi.org/10.14814/phy2.13168
_version_ 1782514607502393344
author Hmeidi, Hamzah
Motamedi‐Fakhr, Shayan
Chadwick, Edward
Gilchrist, Francis J.
Lenney, Warren
Iles, Richard
Wilson, Rachel C.
Alexander, John
author_facet Hmeidi, Hamzah
Motamedi‐Fakhr, Shayan
Chadwick, Edward
Gilchrist, Francis J.
Lenney, Warren
Iles, Richard
Wilson, Rachel C.
Alexander, John
author_sort Hmeidi, Hamzah
collection PubMed
description Structured light plethysmography (SLP) is a light‐based, noncontact technique that measures tidal breathing by monitoring displacements of the thoracoabdominal (TA) wall. We used SLP to measure tidal breathing parameters and their within‐subject variability (v) in 30 children aged 7–16 years with asthma and abnormal spirometry (forced expiratory volume in 1 sec [FEV1] <80% predicted) during a routine clinic appointment. As part of standard care, the reversibility of airway obstruction was assessed by repeating spirometry after administration of an inhaled bronchodilator. In this study, SLP was performed before and after bronchodilator administration, and also once in 41 age‐matched controls. In the asthma group, there was a significant increase in spirometry‐assessed mean FEV1 after administration of bronchodilator. Of all measured tidal breathing parameters, the most informative was the inspiratory to expiratory TA displacement ratio (IE50(SLP), calculated as TIF50(SLP)/TEF50(SLP), where TIF50(SLP) is tidal inspiratory TA displacement rate at 50% of inspiratory displacement and TEF50(SLP) is tidal expiratory TA displacement rate at 50% of expiratory displacement). Median (m) IE50(SLP) and its variability (vIE50(SLP)) were both higher in children with asthma (prebronchodilator) compared with healthy children (mIE50(SLP): 1.53 vs. 1.22, P < 0.001; vIE50(SLP): 0.63 vs. 0.47, P < 0.001). After administration of bronchodilators to the asthma group, mIE50(SLP) decreased from 1.53 to 1.45 (P = 0.01) and vIE50(SLP) decreased from 0.63 to 0.60 (P = 0.04). SLP‐measured tidal breathing parameters could differentiate between children with and without asthma and indicate a response to bronchodilator.
format Online
Article
Text
id pubmed-5350176
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-53501762017-03-17 Tidal breathing parameters measured using structured light plethysmography in healthy children and those with asthma before and after bronchodilator Hmeidi, Hamzah Motamedi‐Fakhr, Shayan Chadwick, Edward Gilchrist, Francis J. Lenney, Warren Iles, Richard Wilson, Rachel C. Alexander, John Physiol Rep Original Research Structured light plethysmography (SLP) is a light‐based, noncontact technique that measures tidal breathing by monitoring displacements of the thoracoabdominal (TA) wall. We used SLP to measure tidal breathing parameters and their within‐subject variability (v) in 30 children aged 7–16 years with asthma and abnormal spirometry (forced expiratory volume in 1 sec [FEV1] <80% predicted) during a routine clinic appointment. As part of standard care, the reversibility of airway obstruction was assessed by repeating spirometry after administration of an inhaled bronchodilator. In this study, SLP was performed before and after bronchodilator administration, and also once in 41 age‐matched controls. In the asthma group, there was a significant increase in spirometry‐assessed mean FEV1 after administration of bronchodilator. Of all measured tidal breathing parameters, the most informative was the inspiratory to expiratory TA displacement ratio (IE50(SLP), calculated as TIF50(SLP)/TEF50(SLP), where TIF50(SLP) is tidal inspiratory TA displacement rate at 50% of inspiratory displacement and TEF50(SLP) is tidal expiratory TA displacement rate at 50% of expiratory displacement). Median (m) IE50(SLP) and its variability (vIE50(SLP)) were both higher in children with asthma (prebronchodilator) compared with healthy children (mIE50(SLP): 1.53 vs. 1.22, P < 0.001; vIE50(SLP): 0.63 vs. 0.47, P < 0.001). After administration of bronchodilators to the asthma group, mIE50(SLP) decreased from 1.53 to 1.45 (P = 0.01) and vIE50(SLP) decreased from 0.63 to 0.60 (P = 0.04). SLP‐measured tidal breathing parameters could differentiate between children with and without asthma and indicate a response to bronchodilator. John Wiley and Sons Inc. 2017-03-08 /pmc/articles/PMC5350176/ /pubmed/28275111 http://dx.doi.org/10.14814/phy2.13168 Text en © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Hmeidi, Hamzah
Motamedi‐Fakhr, Shayan
Chadwick, Edward
Gilchrist, Francis J.
Lenney, Warren
Iles, Richard
Wilson, Rachel C.
Alexander, John
Tidal breathing parameters measured using structured light plethysmography in healthy children and those with asthma before and after bronchodilator
title Tidal breathing parameters measured using structured light plethysmography in healthy children and those with asthma before and after bronchodilator
title_full Tidal breathing parameters measured using structured light plethysmography in healthy children and those with asthma before and after bronchodilator
title_fullStr Tidal breathing parameters measured using structured light plethysmography in healthy children and those with asthma before and after bronchodilator
title_full_unstemmed Tidal breathing parameters measured using structured light plethysmography in healthy children and those with asthma before and after bronchodilator
title_short Tidal breathing parameters measured using structured light plethysmography in healthy children and those with asthma before and after bronchodilator
title_sort tidal breathing parameters measured using structured light plethysmography in healthy children and those with asthma before and after bronchodilator
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5350176/
https://www.ncbi.nlm.nih.gov/pubmed/28275111
http://dx.doi.org/10.14814/phy2.13168
work_keys_str_mv AT hmeidihamzah tidalbreathingparametersmeasuredusingstructuredlightplethysmographyinhealthychildrenandthosewithasthmabeforeandafterbronchodilator
AT motamedifakhrshayan tidalbreathingparametersmeasuredusingstructuredlightplethysmographyinhealthychildrenandthosewithasthmabeforeandafterbronchodilator
AT chadwickedward tidalbreathingparametersmeasuredusingstructuredlightplethysmographyinhealthychildrenandthosewithasthmabeforeandafterbronchodilator
AT gilchristfrancisj tidalbreathingparametersmeasuredusingstructuredlightplethysmographyinhealthychildrenandthosewithasthmabeforeandafterbronchodilator
AT lenneywarren tidalbreathingparametersmeasuredusingstructuredlightplethysmographyinhealthychildrenandthosewithasthmabeforeandafterbronchodilator
AT ilesrichard tidalbreathingparametersmeasuredusingstructuredlightplethysmographyinhealthychildrenandthosewithasthmabeforeandafterbronchodilator
AT wilsonrachelc tidalbreathingparametersmeasuredusingstructuredlightplethysmographyinhealthychildrenandthosewithasthmabeforeandafterbronchodilator
AT alexanderjohn tidalbreathingparametersmeasuredusingstructuredlightplethysmographyinhealthychildrenandthosewithasthmabeforeandafterbronchodilator