Cargando…

Thoracoscopic foreign body removal and repair of bronchus intermedius following injury during failed bronchoscopic retrieval

Aspiration of foreign body (FB) into the airways is common in children and continues to be a cause for morbidity and mortality. We report herein, successful thoracoscopic management of a child who aspirated a large magnetic FB into his right bronchus and developed a tear of bronchus intermedius (BI)...

Descripción completa

Detalles Bibliográficos
Autores principales: Asaf, Belal Bin, Vijay, CL, Bishnoi, Sukhram, Dua, Naresh, Kumar, Arvind
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5351365/
https://www.ncbi.nlm.nih.gov/pubmed/28360471
http://dx.doi.org/10.4103/0970-2113.201296
Descripción
Sumario:Aspiration of foreign body (FB) into the airways is common in children and continues to be a cause for morbidity and mortality. We report herein, successful thoracoscopic management of a child who aspirated a large magnetic FB into his right bronchus and developed a tear of bronchus intermedius (BI) during an attempt at bronchoscopic retrieval using rigid bronchoscope. The impacted FB was successfully removed thoracoscopically followed by thoracoscopic BI repair.