Cargando…

Bench-top Comparison of Physical Properties of 4 Commercially-Available Self-Expanding Intracranial Stents

PURPOSE: To better understand the performance of four commercially available neurovascular stents in intracranial aneurysm embolization, the stents were compared in terms of their basic morphological and mechanical properties. MATERIALS AND METHODS: Four different types of stents that are currently...

Descripción completa

Detalles Bibliográficos
Autores principales: Cho, Su-hee, Jo, Won-il, Jo, Ye-eun, Yang, Ku Hyun, Park, Jung Cheol, Lee, Deok Hee
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Interventional Neuroradiology 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5355459/
https://www.ncbi.nlm.nih.gov/pubmed/28316867
http://dx.doi.org/10.5469/neuroint.2017.12.1.31
Descripción
Sumario:PURPOSE: To better understand the performance of four commercially available neurovascular stents in intracranial aneurysm embolization, the stents were compared in terms of their basic morphological and mechanical properties. MATERIALS AND METHODS: Four different types of stents that are currently being used for cerebral aneurysm embolization were prepared (two stents per type). Two were laser-cut stents (Neuroform and Enterprise) and two were braided from a single nitinol wire (LEO and LVIS stents). All were subjected to quantitative measurements of stent size, pore density, metal coverage, the force needed to load, push, and deploy the stent, radial force on deployment, surface roughness, and corrosion resistance. RESULTS: Compared to their nominal diameters, all stents had greater diameters after deployment. The length generally decreased after deployment. This was particularly marked in the braided stents. The braided stents also had higher pore densities than the laser-cut stents. Metal coverage was highest in the LEO stent (14%) and lowest in the Enterprise stent (5%). The LIVS stent had the highest microcatheter loading force (81.5 gf). The LEO stent had the highest passage force (55.0 gf) and deployment force (78.9 gf). The LVIS and LEO stents had the highest perpendicular (37.1 gf) and circumferential (178.4 gf) radial forces, respectively. The Enterprise stent had the roughest stent wire, followed by the LVIS, LEO, and Neuroform stents. CONCLUSION: The four neurovascular stent types differed in terms of morphological and physical characteristics. An understanding of this diversity may help to decide which stent is most suitable for specific clinical situations.