Comparing Stent Thrombosis associated with Zotarolimus Eluting Stents versus Everolimus Eluting Stents at 1 year follow up: a systematic review and meta-analysis of 6 randomized controlled trials

BACKGROUND: Two thousand fifteen has been a winning year for Drug Eluting Stents (DES). Increase in the number of patients with cardiovascular diseases treated by Percutaneous Coronary Intervention (PCI) has resulted to a high demand for second generation DES. This current analysis aimed to compare...

Descripción completa

Detalles Bibliográficos
Autores principales: Bundhun, Pravesh Kumar, Yanamala, Chandra Mouli, Huang, Wei-Qiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5356408/
https://www.ncbi.nlm.nih.gov/pubmed/28302055
http://dx.doi.org/10.1186/s12872-017-0515-4
_version_ 1782515829273788416
author Bundhun, Pravesh Kumar
Yanamala, Chandra Mouli
Huang, Wei-Qiang
author_facet Bundhun, Pravesh Kumar
Yanamala, Chandra Mouli
Huang, Wei-Qiang
author_sort Bundhun, Pravesh Kumar
collection PubMed
description BACKGROUND: Two thousand fifteen has been a winning year for Drug Eluting Stents (DES). Increase in the number of patients with cardiovascular diseases treated by Percutaneous Coronary Intervention (PCI) has resulted to a high demand for second generation DES. This current analysis aimed to compare the different types of Stent Thrombosis (ST) associated with Zotarolimus Eluting Stents (ZES) versus Everolimus Eluting Stents (EES) at 1 year follow up. METHODS: Electronic databases were searched for studies comparing ZES with EES. Different types of ST reported at 1 year follow up were considered as the primary endpoints in this analysis. Odds Ratios (OR) with 95% Confidence Intervals (CIs) were used as the statistical parameters and the pooled analyses were carried out by the RevMan 5 · 3 software. RESULTS: A total number of 10,512 patients were included in this analysis. No significant difference in any definite ST, acute definite ST, subacute definite ST, and late definite ST were observed between ZES and EES, at 1 year follow up with OR: 1.70, 95% CI: 0.92 – 3.16; P = 0.09, OR: 3.44, 95% CI: 0.82 – 14.43; P = 0.09, OR: 1.13, 95% CI: 0.43 – 2.95; P = 0.80 and OR: 2.39, 95% CI: 0.83 – 6.85; P = 0.11 respectively. Moreover, any definite or probable ST and definite/probable/possible ST were also not significantly different with OR: 1.39, 95% CI: 0.89 – 2.17; P = 0.15 and OR: 1.19, 95% CI: 0.84 – 1.70; P = 0.33 respectively. In addition, any probable ST, acute probable ST, late probable ST and possible ST were also not significantly different at 1 year follow up with OR: 1.11, 95% CI: 0.60 – 2.05; P = 0.75, OR: 0.53, 95% CI: 0.12 – 2.40; P = 0.41, OR: 1.67, 95% CI: 0.35 – 7.86; P = 0.52 and OR: 1.08, 95% CI: 0.64 – 1.82; P = 0.78 respectively. CONCLUSION: At 1 year follow up, ZES were not associated with significantly lower or higher definite and probable ST compared to EES. In addition, no significant difference was observed in acute, subacute and late definite or probable ST. However, further trials are recommended to assess the effects of these second-generation DES during the long-term.
format Online
Article
Text
id pubmed-5356408
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-53564082017-03-22 Comparing Stent Thrombosis associated with Zotarolimus Eluting Stents versus Everolimus Eluting Stents at 1 year follow up: a systematic review and meta-analysis of 6 randomized controlled trials Bundhun, Pravesh Kumar Yanamala, Chandra Mouli Huang, Wei-Qiang BMC Cardiovasc Disord Research Article BACKGROUND: Two thousand fifteen has been a winning year for Drug Eluting Stents (DES). Increase in the number of patients with cardiovascular diseases treated by Percutaneous Coronary Intervention (PCI) has resulted to a high demand for second generation DES. This current analysis aimed to compare the different types of Stent Thrombosis (ST) associated with Zotarolimus Eluting Stents (ZES) versus Everolimus Eluting Stents (EES) at 1 year follow up. METHODS: Electronic databases were searched for studies comparing ZES with EES. Different types of ST reported at 1 year follow up were considered as the primary endpoints in this analysis. Odds Ratios (OR) with 95% Confidence Intervals (CIs) were used as the statistical parameters and the pooled analyses were carried out by the RevMan 5 · 3 software. RESULTS: A total number of 10,512 patients were included in this analysis. No significant difference in any definite ST, acute definite ST, subacute definite ST, and late definite ST were observed between ZES and EES, at 1 year follow up with OR: 1.70, 95% CI: 0.92 – 3.16; P = 0.09, OR: 3.44, 95% CI: 0.82 – 14.43; P = 0.09, OR: 1.13, 95% CI: 0.43 – 2.95; P = 0.80 and OR: 2.39, 95% CI: 0.83 – 6.85; P = 0.11 respectively. Moreover, any definite or probable ST and definite/probable/possible ST were also not significantly different with OR: 1.39, 95% CI: 0.89 – 2.17; P = 0.15 and OR: 1.19, 95% CI: 0.84 – 1.70; P = 0.33 respectively. In addition, any probable ST, acute probable ST, late probable ST and possible ST were also not significantly different at 1 year follow up with OR: 1.11, 95% CI: 0.60 – 2.05; P = 0.75, OR: 0.53, 95% CI: 0.12 – 2.40; P = 0.41, OR: 1.67, 95% CI: 0.35 – 7.86; P = 0.52 and OR: 1.08, 95% CI: 0.64 – 1.82; P = 0.78 respectively. CONCLUSION: At 1 year follow up, ZES were not associated with significantly lower or higher definite and probable ST compared to EES. In addition, no significant difference was observed in acute, subacute and late definite or probable ST. However, further trials are recommended to assess the effects of these second-generation DES during the long-term. BioMed Central 2017-03-16 /pmc/articles/PMC5356408/ /pubmed/28302055 http://dx.doi.org/10.1186/s12872-017-0515-4 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Bundhun, Pravesh Kumar
Yanamala, Chandra Mouli
Huang, Wei-Qiang
Comparing Stent Thrombosis associated with Zotarolimus Eluting Stents versus Everolimus Eluting Stents at 1 year follow up: a systematic review and meta-analysis of 6 randomized controlled trials
title Comparing Stent Thrombosis associated with Zotarolimus Eluting Stents versus Everolimus Eluting Stents at 1 year follow up: a systematic review and meta-analysis of 6 randomized controlled trials
title_full Comparing Stent Thrombosis associated with Zotarolimus Eluting Stents versus Everolimus Eluting Stents at 1 year follow up: a systematic review and meta-analysis of 6 randomized controlled trials
title_fullStr Comparing Stent Thrombosis associated with Zotarolimus Eluting Stents versus Everolimus Eluting Stents at 1 year follow up: a systematic review and meta-analysis of 6 randomized controlled trials
title_full_unstemmed Comparing Stent Thrombosis associated with Zotarolimus Eluting Stents versus Everolimus Eluting Stents at 1 year follow up: a systematic review and meta-analysis of 6 randomized controlled trials
title_short Comparing Stent Thrombosis associated with Zotarolimus Eluting Stents versus Everolimus Eluting Stents at 1 year follow up: a systematic review and meta-analysis of 6 randomized controlled trials
title_sort comparing stent thrombosis associated with zotarolimus eluting stents versus everolimus eluting stents at 1 year follow up: a systematic review and meta-analysis of 6 randomized controlled trials
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5356408/
https://www.ncbi.nlm.nih.gov/pubmed/28302055
http://dx.doi.org/10.1186/s12872-017-0515-4
work_keys_str_mv AT bundhunpraveshkumar comparingstentthrombosisassociatedwithzotarolimuselutingstentsversuseverolimuselutingstentsat1yearfollowupasystematicreviewandmetaanalysisof6randomizedcontrolledtrials
AT yanamalachandramouli comparingstentthrombosisassociatedwithzotarolimuselutingstentsversuseverolimuselutingstentsat1yearfollowupasystematicreviewandmetaanalysisof6randomizedcontrolledtrials
AT huangweiqiang comparingstentthrombosisassociatedwithzotarolimuselutingstentsversuseverolimuselutingstentsat1yearfollowupasystematicreviewandmetaanalysisof6randomizedcontrolledtrials