Diagnosis accuracy of two vision screeners for visual health surveillance of workers who use video display terminals

OBJECTIVE: To compare the diagnostic accuracy of two vision screeners by a visual examination performed by an optometrist (gold standard) and to evaluate the concordance between both screeners and between each screener and the gold standard. METHODS: This was a cross-sectional study that included co...

Descripción completa

Detalles Bibliográficos
Autores principales: Molina-Torres, María-José, Crespo, María-del-Mar Seguí, Francés, Ana Tauste, Lacarra, Blanca Lumbreras, Ronda-Pérez, Elena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japan Society for Occupational Health 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5356978/
https://www.ncbi.nlm.nih.gov/pubmed/27488039
_version_ 1782515960357322752
author Molina-Torres, María-José
Crespo, María-del-Mar Seguí
Francés, Ana Tauste
Lacarra, Blanca Lumbreras
Ronda-Pérez, Elena
author_facet Molina-Torres, María-José
Crespo, María-del-Mar Seguí
Francés, Ana Tauste
Lacarra, Blanca Lumbreras
Ronda-Pérez, Elena
author_sort Molina-Torres, María-José
collection PubMed
description OBJECTIVE: To compare the diagnostic accuracy of two vision screeners by a visual examination performed by an optometrist (gold standard) and to evaluate the concordance between both screeners and between each screener and the gold standard. METHODS: This was a cross-sectional study that included computer workers who attended a routine yearly health examination. The study included administrative office workers (n=91) aged 50.2±7.9 years (mean±standard deviation), 69.2% of whom were women and 68.1% of whom used video display terminals (VDT) for >4 h/day. The routine visual examination included monocular and binocular distance visual acuity (VA), distance and near lateral phoria (LP), stereo acuity (SA), and color vision. Tests were repeated with Optec 6500 (by Stereo Optical) and Visiotest (by Essilor) screeners. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), and false positive and negative rates were calculated. Kappa coefficient (κ) was used to measure the concordance of the screeners and the gold standard. RESULTS: The sensitivity and specificity for monocular VA were over 80% for both vision screeners; PPV was below 25%. Sensitivity and specificity were lower for SA (55%-70%), PPV was 50%, and NPV was 75% for both screeners. For distance LP, sensitivity and PPV were <10% in both cases. The screeners differed in their values for near LP: Optec 6500 had higher sensitivity (43.5%), PPV (37.0%), and NPV (79.7%); whereas the Visiotest had higher specificity (83.8%). For color vision, Visiotest showed low sensitivity, low PPV, and high specificity. Visiotest obtained false positive rates that were lower or similar to Optec 6500, and both screeners obtained false negative rates below 50%. Both screeners showed poor concordance (κ<0.40). CONCLUSIONS: A high value for NPV would qualify both screeners as acceptable alternatives for visual health surveillance when used as a screening tool; patients with positive test results should be referred to a specialist.
format Online
Article
Text
id pubmed-5356978
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Japan Society for Occupational Health
record_format MEDLINE/PubMed
spelling pubmed-53569782017-03-23 Diagnosis accuracy of two vision screeners for visual health surveillance of workers who use video display terminals Molina-Torres, María-José Crespo, María-del-Mar Seguí Francés, Ana Tauste Lacarra, Blanca Lumbreras Ronda-Pérez, Elena J Occup Health Original OBJECTIVE: To compare the diagnostic accuracy of two vision screeners by a visual examination performed by an optometrist (gold standard) and to evaluate the concordance between both screeners and between each screener and the gold standard. METHODS: This was a cross-sectional study that included computer workers who attended a routine yearly health examination. The study included administrative office workers (n=91) aged 50.2±7.9 years (mean±standard deviation), 69.2% of whom were women and 68.1% of whom used video display terminals (VDT) for >4 h/day. The routine visual examination included monocular and binocular distance visual acuity (VA), distance and near lateral phoria (LP), stereo acuity (SA), and color vision. Tests were repeated with Optec 6500 (by Stereo Optical) and Visiotest (by Essilor) screeners. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), and false positive and negative rates were calculated. Kappa coefficient (κ) was used to measure the concordance of the screeners and the gold standard. RESULTS: The sensitivity and specificity for monocular VA were over 80% for both vision screeners; PPV was below 25%. Sensitivity and specificity were lower for SA (55%-70%), PPV was 50%, and NPV was 75% for both screeners. For distance LP, sensitivity and PPV were <10% in both cases. The screeners differed in their values for near LP: Optec 6500 had higher sensitivity (43.5%), PPV (37.0%), and NPV (79.7%); whereas the Visiotest had higher specificity (83.8%). For color vision, Visiotest showed low sensitivity, low PPV, and high specificity. Visiotest obtained false positive rates that were lower or similar to Optec 6500, and both screeners obtained false negative rates below 50%. Both screeners showed poor concordance (κ<0.40). CONCLUSIONS: A high value for NPV would qualify both screeners as acceptable alternatives for visual health surveillance when used as a screening tool; patients with positive test results should be referred to a specialist. Japan Society for Occupational Health 2016-08-04 2016-09-20 /pmc/articles/PMC5356978/ /pubmed/27488039 Text en https://creativecommons.org/licenses/by-nc-sa/4.0/ Journal of Occupational Health is an Open Access article distributed under the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License. To view the details of this license, please visit (https://creativecommons.org/licenses/by-nc-sa/4.0/).
spellingShingle Original
Molina-Torres, María-José
Crespo, María-del-Mar Seguí
Francés, Ana Tauste
Lacarra, Blanca Lumbreras
Ronda-Pérez, Elena
Diagnosis accuracy of two vision screeners for visual health surveillance of workers who use video display terminals
title Diagnosis accuracy of two vision screeners for visual health surveillance of workers who use video display terminals
title_full Diagnosis accuracy of two vision screeners for visual health surveillance of workers who use video display terminals
title_fullStr Diagnosis accuracy of two vision screeners for visual health surveillance of workers who use video display terminals
title_full_unstemmed Diagnosis accuracy of two vision screeners for visual health surveillance of workers who use video display terminals
title_short Diagnosis accuracy of two vision screeners for visual health surveillance of workers who use video display terminals
title_sort diagnosis accuracy of two vision screeners for visual health surveillance of workers who use video display terminals
topic Original
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5356978/
https://www.ncbi.nlm.nih.gov/pubmed/27488039
work_keys_str_mv AT molinatorresmariajose diagnosisaccuracyoftwovisionscreenersforvisualhealthsurveillanceofworkerswhousevideodisplayterminals
AT crespomariadelmarsegui diagnosisaccuracyoftwovisionscreenersforvisualhealthsurveillanceofworkerswhousevideodisplayterminals
AT francesanatauste diagnosisaccuracyoftwovisionscreenersforvisualhealthsurveillanceofworkerswhousevideodisplayterminals
AT lacarrablancalumbreras diagnosisaccuracyoftwovisionscreenersforvisualhealthsurveillanceofworkerswhousevideodisplayterminals
AT rondaperezelena diagnosisaccuracyoftwovisionscreenersforvisualhealthsurveillanceofworkerswhousevideodisplayterminals