Cargando…
Safety and efficacy in parous women of a 52-mg levonorgestrel-medicated intrauterine device: a 7-year randomized comparative study with the TCu380A()()
OBJECTIVES: To compare rates of unintended pregnancy, method continuation and reasons for removal among women using the 52-mg levonorgestrel (daily release 20 microg) levonorgestrel IUD (LNG-IUD) or the copper T 380 A (TCu380A) intrauterine device. STUDY DESIGN: This was an open-label 7-year randomi...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5357727/ https://www.ncbi.nlm.nih.gov/pubmed/26916172 http://dx.doi.org/10.1016/j.contraception.2016.02.024 |
_version_ | 1782516090480361472 |
---|---|
author | Rowe, Patrick Farley, Tim Peregoudov, Alexandre Piaggio, Gilda Boccard, Simone Landoulsi, Sihem Meirik, Olav |
author_facet | Rowe, Patrick Farley, Tim Peregoudov, Alexandre Piaggio, Gilda Boccard, Simone Landoulsi, Sihem Meirik, Olav |
author_sort | Rowe, Patrick |
collection | PubMed |
description | OBJECTIVES: To compare rates of unintended pregnancy, method continuation and reasons for removal among women using the 52-mg levonorgestrel (daily release 20 microg) levonorgestrel IUD (LNG-IUD) or the copper T 380 A (TCu380A) intrauterine device. STUDY DESIGN: This was an open-label 7-year randomized controlled trial in 20 centres, 11 of which in China. Data on 1884 women with interval insertion of the LNG-IUD and 1871 of the TCu380A were analysed using life tables with 30-day intervals and Cox proportional hazards models. RESULTS: The cumulative 7-year pregnancy rate of the LNG-IUD was 0.5 (standard error 0.2) per 100, significantly lower than 2.5 (0.4) per 100 of the TCu380A, cumulative method discontinuation rates at 7 years were 70.6 (1.2) and 40.8 (1.3) per 100, respectively. Dominant reasons for discontinuing the LNG-IUD were amenorrhea (26.1 [1.3] per 100) and reduced bleeding (12.5 [1.1] per 100), particularly in Chinese women and, for the TCu380A, increased bleeding (9.9 [0.9] per 100), especially among non-Chinese women. Removal rates for pain were similar for the two intrauterine devices (IUDs). Cumulative rates of removal for symptoms compatible with hormonal side effects were 5.7 (0.7) and 0.4 (0.2) per 100 for the LNG-IUD and TCu380A, respectively, and cumulative losses to follow-up at 7 years were 26.0 (1.4) and 36.9 (1.3) per 100, respectively. CONCLUSION: The LNG-IUD and the TCu380A have very high contraceptive efficacy, with the LNG-IUD significantly higher than the TCu380A. Overall rates of IUD removals were higher among LNG-IUD users than TCu380A users. Removals for amenorrhea appeared culturally associated. IMPLICATIONS: The 52-mg LNG-IUD and the TCu380A have very high contraceptive efficacy through 7 years. As an IUD, the unique side effects of the LNG-IUD are reduced bleeding, amenorrhea and symptoms compatible with hormonal contraceptives. |
format | Online Article Text |
id | pubmed-5357727 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-53577272017-03-28 Safety and efficacy in parous women of a 52-mg levonorgestrel-medicated intrauterine device: a 7-year randomized comparative study with the TCu380A()() Rowe, Patrick Farley, Tim Peregoudov, Alexandre Piaggio, Gilda Boccard, Simone Landoulsi, Sihem Meirik, Olav Contraception Original Research Article OBJECTIVES: To compare rates of unintended pregnancy, method continuation and reasons for removal among women using the 52-mg levonorgestrel (daily release 20 microg) levonorgestrel IUD (LNG-IUD) or the copper T 380 A (TCu380A) intrauterine device. STUDY DESIGN: This was an open-label 7-year randomized controlled trial in 20 centres, 11 of which in China. Data on 1884 women with interval insertion of the LNG-IUD and 1871 of the TCu380A were analysed using life tables with 30-day intervals and Cox proportional hazards models. RESULTS: The cumulative 7-year pregnancy rate of the LNG-IUD was 0.5 (standard error 0.2) per 100, significantly lower than 2.5 (0.4) per 100 of the TCu380A, cumulative method discontinuation rates at 7 years were 70.6 (1.2) and 40.8 (1.3) per 100, respectively. Dominant reasons for discontinuing the LNG-IUD were amenorrhea (26.1 [1.3] per 100) and reduced bleeding (12.5 [1.1] per 100), particularly in Chinese women and, for the TCu380A, increased bleeding (9.9 [0.9] per 100), especially among non-Chinese women. Removal rates for pain were similar for the two intrauterine devices (IUDs). Cumulative rates of removal for symptoms compatible with hormonal side effects were 5.7 (0.7) and 0.4 (0.2) per 100 for the LNG-IUD and TCu380A, respectively, and cumulative losses to follow-up at 7 years were 26.0 (1.4) and 36.9 (1.3) per 100, respectively. CONCLUSION: The LNG-IUD and the TCu380A have very high contraceptive efficacy, with the LNG-IUD significantly higher than the TCu380A. Overall rates of IUD removals were higher among LNG-IUD users than TCu380A users. Removals for amenorrhea appeared culturally associated. IMPLICATIONS: The 52-mg LNG-IUD and the TCu380A have very high contraceptive efficacy through 7 years. As an IUD, the unique side effects of the LNG-IUD are reduced bleeding, amenorrhea and symptoms compatible with hormonal contraceptives. Elsevier 2016-06 /pmc/articles/PMC5357727/ /pubmed/26916172 http://dx.doi.org/10.1016/j.contraception.2016.02.024 Text en © 2016 Published by Elsevier Inc. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Research Article Rowe, Patrick Farley, Tim Peregoudov, Alexandre Piaggio, Gilda Boccard, Simone Landoulsi, Sihem Meirik, Olav Safety and efficacy in parous women of a 52-mg levonorgestrel-medicated intrauterine device: a 7-year randomized comparative study with the TCu380A()() |
title | Safety and efficacy in parous women of a 52-mg levonorgestrel-medicated intrauterine device: a 7-year randomized comparative study with the TCu380A()() |
title_full | Safety and efficacy in parous women of a 52-mg levonorgestrel-medicated intrauterine device: a 7-year randomized comparative study with the TCu380A()() |
title_fullStr | Safety and efficacy in parous women of a 52-mg levonorgestrel-medicated intrauterine device: a 7-year randomized comparative study with the TCu380A()() |
title_full_unstemmed | Safety and efficacy in parous women of a 52-mg levonorgestrel-medicated intrauterine device: a 7-year randomized comparative study with the TCu380A()() |
title_short | Safety and efficacy in parous women of a 52-mg levonorgestrel-medicated intrauterine device: a 7-year randomized comparative study with the TCu380A()() |
title_sort | safety and efficacy in parous women of a 52-mg levonorgestrel-medicated intrauterine device: a 7-year randomized comparative study with the tcu380a()() |
topic | Original Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5357727/ https://www.ncbi.nlm.nih.gov/pubmed/26916172 http://dx.doi.org/10.1016/j.contraception.2016.02.024 |
work_keys_str_mv | AT rowepatrick safetyandefficacyinparouswomenofa52mglevonorgestrelmedicatedintrauterinedevicea7yearrandomizedcomparativestudywiththetcu380a AT farleytim safetyandefficacyinparouswomenofa52mglevonorgestrelmedicatedintrauterinedevicea7yearrandomizedcomparativestudywiththetcu380a AT peregoudovalexandre safetyandefficacyinparouswomenofa52mglevonorgestrelmedicatedintrauterinedevicea7yearrandomizedcomparativestudywiththetcu380a AT piaggiogilda safetyandefficacyinparouswomenofa52mglevonorgestrelmedicatedintrauterinedevicea7yearrandomizedcomparativestudywiththetcu380a AT boccardsimone safetyandefficacyinparouswomenofa52mglevonorgestrelmedicatedintrauterinedevicea7yearrandomizedcomparativestudywiththetcu380a AT landoulsisihem safetyandefficacyinparouswomenofa52mglevonorgestrelmedicatedintrauterinedevicea7yearrandomizedcomparativestudywiththetcu380a AT meirikolav safetyandefficacyinparouswomenofa52mglevonorgestrelmedicatedintrauterinedevicea7yearrandomizedcomparativestudywiththetcu380a AT safetyandefficacyinparouswomenofa52mglevonorgestrelmedicatedintrauterinedevicea7yearrandomizedcomparativestudywiththetcu380a |