Predictors of Recurrent Atrial Fibrillation Using Mode Switch Quantification

BACKGROUND: The efficacy of mode switching to predict atrial fibrillation has been established in the literature. There have been few studies investigating the incidence and clinical implication of mode switch episodes quantified from implantable cardioverter defibrillator and pacemaker interrogatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Ruisi, Phillip, Makaryus, John N., Catanzaro, John N., Ruisi, Michael, Cedrone, Anthony, Makaryus, Amgad N., Altman, Erik, Jadonath, Ram, Beldner, Stuart
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elmer Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5358197/
https://www.ncbi.nlm.nih.gov/pubmed/28352435
http://dx.doi.org/10.4021/cr292w
_version_ 1782516185427869696
author Ruisi, Phillip
Makaryus, John N.
Catanzaro, John N.
Ruisi, Michael
Cedrone, Anthony
Makaryus, Amgad N.
Altman, Erik
Jadonath, Ram
Beldner, Stuart
author_facet Ruisi, Phillip
Makaryus, John N.
Catanzaro, John N.
Ruisi, Michael
Cedrone, Anthony
Makaryus, Amgad N.
Altman, Erik
Jadonath, Ram
Beldner, Stuart
author_sort Ruisi, Phillip
collection PubMed
description BACKGROUND: The efficacy of mode switching to predict atrial fibrillation has been established in the literature. There have been few studies investigating the incidence and clinical implication of mode switch episodes quantified from implantable cardioverter defibrillator and pacemaker interrogation. We sought to investigate the incidence of mode switch recurrence in patients with implantable cardioverter defibrillators and permanent pacemakers. METHODS: Mode switch was defined as any occurrence documented during device interrogation after the date of implantation. Clinical predictors (age, gender, hypertension, diabetes, syncope, atrial fibrillation (AF)), and medications were analyzed to determine association with single and recurrent mode switch occurrences. RESULTS: There were 21 patients experiencing a mode switch event, identified from a group of 54 patients (42 males; mean age 70 ± 12 years; mean follow-up 29.1 ± 22 months (3.4 - 81.4 months)). All but two patients were receiving medical therapy including beta blockers, statins, ace-inhibitors, and anti-arrhythmics. There were 21 subjects who experienced at least one mode switch during their follow-up and 33 subjects who never experienced a mode switch during their follow-up time. The median time to first mode switch from device implantation was 39.3 months. Risk factors individually associated with any mode switch episode included: diabetes (DM) (P < 0.04) and use of digitalis (P = 0.02). Subjects who had a history of DM were 5 times more likely to have at least one mode switch occurrence. There was a significantly higher rate of mode switch among patients who were diabetic than patients who were not (3.7 per follow-up month ± 5.3 vs. 0.98 per follow-up month ± 2.02; P = 0.02). There was a significantly higher rate of mode switch among patients who were on digitalis than those who were not (3.1 per follow-up month ± 4.3 vs. 0.73 per follow-up month ± 1.9; P = 0.02). CONCLUSION: The main factors associated with any mode switch are having a history of diabetes and digitalis use. Those patients who are diabetics and those on digitalis may warrant closer observation and management for the development of atrial fibrillation.
format Online
Article
Text
id pubmed-5358197
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Elmer Press
record_format MEDLINE/PubMed
spelling pubmed-53581972017-03-28 Predictors of Recurrent Atrial Fibrillation Using Mode Switch Quantification Ruisi, Phillip Makaryus, John N. Catanzaro, John N. Ruisi, Michael Cedrone, Anthony Makaryus, Amgad N. Altman, Erik Jadonath, Ram Beldner, Stuart Cardiol Res Original Article BACKGROUND: The efficacy of mode switching to predict atrial fibrillation has been established in the literature. There have been few studies investigating the incidence and clinical implication of mode switch episodes quantified from implantable cardioverter defibrillator and pacemaker interrogation. We sought to investigate the incidence of mode switch recurrence in patients with implantable cardioverter defibrillators and permanent pacemakers. METHODS: Mode switch was defined as any occurrence documented during device interrogation after the date of implantation. Clinical predictors (age, gender, hypertension, diabetes, syncope, atrial fibrillation (AF)), and medications were analyzed to determine association with single and recurrent mode switch occurrences. RESULTS: There were 21 patients experiencing a mode switch event, identified from a group of 54 patients (42 males; mean age 70 ± 12 years; mean follow-up 29.1 ± 22 months (3.4 - 81.4 months)). All but two patients were receiving medical therapy including beta blockers, statins, ace-inhibitors, and anti-arrhythmics. There were 21 subjects who experienced at least one mode switch during their follow-up and 33 subjects who never experienced a mode switch during their follow-up time. The median time to first mode switch from device implantation was 39.3 months. Risk factors individually associated with any mode switch episode included: diabetes (DM) (P < 0.04) and use of digitalis (P = 0.02). Subjects who had a history of DM were 5 times more likely to have at least one mode switch occurrence. There was a significantly higher rate of mode switch among patients who were diabetic than patients who were not (3.7 per follow-up month ± 5.3 vs. 0.98 per follow-up month ± 2.02; P = 0.02). There was a significantly higher rate of mode switch among patients who were on digitalis than those who were not (3.1 per follow-up month ± 4.3 vs. 0.73 per follow-up month ± 1.9; P = 0.02). CONCLUSION: The main factors associated with any mode switch are having a history of diabetes and digitalis use. Those patients who are diabetics and those on digitalis may warrant closer observation and management for the development of atrial fibrillation. Elmer Press 2013-10 2013-10-15 /pmc/articles/PMC5358197/ /pubmed/28352435 http://dx.doi.org/10.4021/cr292w Text en Copyright 2013, Ruisi et al. http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Ruisi, Phillip
Makaryus, John N.
Catanzaro, John N.
Ruisi, Michael
Cedrone, Anthony
Makaryus, Amgad N.
Altman, Erik
Jadonath, Ram
Beldner, Stuart
Predictors of Recurrent Atrial Fibrillation Using Mode Switch Quantification
title Predictors of Recurrent Atrial Fibrillation Using Mode Switch Quantification
title_full Predictors of Recurrent Atrial Fibrillation Using Mode Switch Quantification
title_fullStr Predictors of Recurrent Atrial Fibrillation Using Mode Switch Quantification
title_full_unstemmed Predictors of Recurrent Atrial Fibrillation Using Mode Switch Quantification
title_short Predictors of Recurrent Atrial Fibrillation Using Mode Switch Quantification
title_sort predictors of recurrent atrial fibrillation using mode switch quantification
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5358197/
https://www.ncbi.nlm.nih.gov/pubmed/28352435
http://dx.doi.org/10.4021/cr292w
work_keys_str_mv AT ruisiphillip predictorsofrecurrentatrialfibrillationusingmodeswitchquantification
AT makaryusjohnn predictorsofrecurrentatrialfibrillationusingmodeswitchquantification
AT catanzarojohnn predictorsofrecurrentatrialfibrillationusingmodeswitchquantification
AT ruisimichael predictorsofrecurrentatrialfibrillationusingmodeswitchquantification
AT cedroneanthony predictorsofrecurrentatrialfibrillationusingmodeswitchquantification
AT makaryusamgadn predictorsofrecurrentatrialfibrillationusingmodeswitchquantification
AT altmanerik predictorsofrecurrentatrialfibrillationusingmodeswitchquantification
AT jadonathram predictorsofrecurrentatrialfibrillationusingmodeswitchquantification
AT beldnerstuart predictorsofrecurrentatrialfibrillationusingmodeswitchquantification