Cargando…
A topology-based method to mitigate the dosimetric uncertainty caused by the positional variation of the boost volume in breast conservative radiotherapy
BACKGROUND: To improve local control rate in patients with breast cancer receiving adjuvant radiotherapy after breast conservative surgery, additional boost dose to the tumor bed could be delivered simultaneously via the simultaneous integrated boost (SIB) modulated technique. However, the position...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5359879/ https://www.ncbi.nlm.nih.gov/pubmed/28320428 http://dx.doi.org/10.1186/s13014-017-0801-4 |
_version_ | 1782516474119716864 |
---|---|
author | Lee, Peng-Yi Lin, Chih-Yuan Chen, Shang-Wen Chien, Chun-Ru Chu, Chun-Nan Hsu, Hsiu-Ting Liang, Ji-An Lin, Ying-Jun Shiau, An-Cheng |
author_facet | Lee, Peng-Yi Lin, Chih-Yuan Chen, Shang-Wen Chien, Chun-Ru Chu, Chun-Nan Hsu, Hsiu-Ting Liang, Ji-An Lin, Ying-Jun Shiau, An-Cheng |
author_sort | Lee, Peng-Yi |
collection | PubMed |
description | BACKGROUND: To improve local control rate in patients with breast cancer receiving adjuvant radiotherapy after breast conservative surgery, additional boost dose to the tumor bed could be delivered simultaneously via the simultaneous integrated boost (SIB) modulated technique. However, the position of tumor bed kept changing during the treatment course as the treatment position was aligned to bony anatomy. This study aimed to analyze the positional uncertainties between bony anatomy and tumor bed, and a topology-based approach was derived to stratify patients with high variation in tumor bed localization. METHODS: Sixty patients with early-stage breast cancer or ductal carcinoma in situ were enrolled. All received adjuvant whole breast radiotherapy with or without local boost via SIB technique. The delineation of tumor bed was defined by incorporating the anatomy of seroma, adjacent surgical clips, and any architectural distortion on computed tomography simulation. A total of 1740 on-board images were retrospectively analyzed. Positional uncertainty of tumor bed was assessed by four components: namely systematic error (SE), and random error (RE), through anterior-posterior (AP), cranial-caudal (CC), left-right (LR) directions and couch rotation (CR). Age, tumor location, and body-mass factors including volume of breast, volume of tumor bed, breast thickness, and body mass index (BMI) were analyzed for their predictive role. The appropriate margin to accommodate the positional uncertainty of the boost volume was assessed, and the new plans with this margin for the tumor bed was designed as the high risk planning target volume (PTV-H) were created retrospectively to evaluate the impact on organs at risk. RESULTS: In univariate analysis, a larger breast thickness, larger breast volume, higher BMI, and different tumor locations correlated with a greater positional uncertainty of tumor bed. However, BMI was the only factor associated with displacements of surgical clips in the multivariate analysis and patients with higher BMI were stratified as high variation group. When image guidance was aligned to bony structures, the SE and RE of clip displacement were consistently larger in the high variation group. The corresponding PTV-H margins for the high- and low-variation groups were 7, 10, 10 mm and 4, 9, 6 mm in AP, CC, LR directions, respectively. The heart dose between the two plans was not significantly different, whereas the dosimetric parameters for the ipsilateral lung were generally higher in the new plans. CONCLUSIONS: In patients with breast cancer receiving adjuvant radiotherapy, a higher BMI is associated with a greater positional uncertainty of the boost tumor volume. More generous margin should be considered and it can be safely applied through proper design of beam arrangement with advanced treatment techniques. |
format | Online Article Text |
id | pubmed-5359879 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-53598792017-03-22 A topology-based method to mitigate the dosimetric uncertainty caused by the positional variation of the boost volume in breast conservative radiotherapy Lee, Peng-Yi Lin, Chih-Yuan Chen, Shang-Wen Chien, Chun-Ru Chu, Chun-Nan Hsu, Hsiu-Ting Liang, Ji-An Lin, Ying-Jun Shiau, An-Cheng Radiat Oncol Research BACKGROUND: To improve local control rate in patients with breast cancer receiving adjuvant radiotherapy after breast conservative surgery, additional boost dose to the tumor bed could be delivered simultaneously via the simultaneous integrated boost (SIB) modulated technique. However, the position of tumor bed kept changing during the treatment course as the treatment position was aligned to bony anatomy. This study aimed to analyze the positional uncertainties between bony anatomy and tumor bed, and a topology-based approach was derived to stratify patients with high variation in tumor bed localization. METHODS: Sixty patients with early-stage breast cancer or ductal carcinoma in situ were enrolled. All received adjuvant whole breast radiotherapy with or without local boost via SIB technique. The delineation of tumor bed was defined by incorporating the anatomy of seroma, adjacent surgical clips, and any architectural distortion on computed tomography simulation. A total of 1740 on-board images were retrospectively analyzed. Positional uncertainty of tumor bed was assessed by four components: namely systematic error (SE), and random error (RE), through anterior-posterior (AP), cranial-caudal (CC), left-right (LR) directions and couch rotation (CR). Age, tumor location, and body-mass factors including volume of breast, volume of tumor bed, breast thickness, and body mass index (BMI) were analyzed for their predictive role. The appropriate margin to accommodate the positional uncertainty of the boost volume was assessed, and the new plans with this margin for the tumor bed was designed as the high risk planning target volume (PTV-H) were created retrospectively to evaluate the impact on organs at risk. RESULTS: In univariate analysis, a larger breast thickness, larger breast volume, higher BMI, and different tumor locations correlated with a greater positional uncertainty of tumor bed. However, BMI was the only factor associated with displacements of surgical clips in the multivariate analysis and patients with higher BMI were stratified as high variation group. When image guidance was aligned to bony structures, the SE and RE of clip displacement were consistently larger in the high variation group. The corresponding PTV-H margins for the high- and low-variation groups were 7, 10, 10 mm and 4, 9, 6 mm in AP, CC, LR directions, respectively. The heart dose between the two plans was not significantly different, whereas the dosimetric parameters for the ipsilateral lung were generally higher in the new plans. CONCLUSIONS: In patients with breast cancer receiving adjuvant radiotherapy, a higher BMI is associated with a greater positional uncertainty of the boost tumor volume. More generous margin should be considered and it can be safely applied through proper design of beam arrangement with advanced treatment techniques. BioMed Central 2017-03-20 /pmc/articles/PMC5359879/ /pubmed/28320428 http://dx.doi.org/10.1186/s13014-017-0801-4 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Lee, Peng-Yi Lin, Chih-Yuan Chen, Shang-Wen Chien, Chun-Ru Chu, Chun-Nan Hsu, Hsiu-Ting Liang, Ji-An Lin, Ying-Jun Shiau, An-Cheng A topology-based method to mitigate the dosimetric uncertainty caused by the positional variation of the boost volume in breast conservative radiotherapy |
title | A topology-based method to mitigate the dosimetric uncertainty caused by the positional variation of the boost volume in breast conservative radiotherapy |
title_full | A topology-based method to mitigate the dosimetric uncertainty caused by the positional variation of the boost volume in breast conservative radiotherapy |
title_fullStr | A topology-based method to mitigate the dosimetric uncertainty caused by the positional variation of the boost volume in breast conservative radiotherapy |
title_full_unstemmed | A topology-based method to mitigate the dosimetric uncertainty caused by the positional variation of the boost volume in breast conservative radiotherapy |
title_short | A topology-based method to mitigate the dosimetric uncertainty caused by the positional variation of the boost volume in breast conservative radiotherapy |
title_sort | topology-based method to mitigate the dosimetric uncertainty caused by the positional variation of the boost volume in breast conservative radiotherapy |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5359879/ https://www.ncbi.nlm.nih.gov/pubmed/28320428 http://dx.doi.org/10.1186/s13014-017-0801-4 |
work_keys_str_mv | AT leepengyi atopologybasedmethodtomitigatethedosimetricuncertaintycausedbythepositionalvariationoftheboostvolumeinbreastconservativeradiotherapy AT linchihyuan atopologybasedmethodtomitigatethedosimetricuncertaintycausedbythepositionalvariationoftheboostvolumeinbreastconservativeradiotherapy AT chenshangwen atopologybasedmethodtomitigatethedosimetricuncertaintycausedbythepositionalvariationoftheboostvolumeinbreastconservativeradiotherapy AT chienchunru atopologybasedmethodtomitigatethedosimetricuncertaintycausedbythepositionalvariationoftheboostvolumeinbreastconservativeradiotherapy AT chuchunnan atopologybasedmethodtomitigatethedosimetricuncertaintycausedbythepositionalvariationoftheboostvolumeinbreastconservativeradiotherapy AT hsuhsiuting atopologybasedmethodtomitigatethedosimetricuncertaintycausedbythepositionalvariationoftheboostvolumeinbreastconservativeradiotherapy AT liangjian atopologybasedmethodtomitigatethedosimetricuncertaintycausedbythepositionalvariationoftheboostvolumeinbreastconservativeradiotherapy AT linyingjun atopologybasedmethodtomitigatethedosimetricuncertaintycausedbythepositionalvariationoftheboostvolumeinbreastconservativeradiotherapy AT shiauancheng atopologybasedmethodtomitigatethedosimetricuncertaintycausedbythepositionalvariationoftheboostvolumeinbreastconservativeradiotherapy AT leepengyi topologybasedmethodtomitigatethedosimetricuncertaintycausedbythepositionalvariationoftheboostvolumeinbreastconservativeradiotherapy AT linchihyuan topologybasedmethodtomitigatethedosimetricuncertaintycausedbythepositionalvariationoftheboostvolumeinbreastconservativeradiotherapy AT chenshangwen topologybasedmethodtomitigatethedosimetricuncertaintycausedbythepositionalvariationoftheboostvolumeinbreastconservativeradiotherapy AT chienchunru topologybasedmethodtomitigatethedosimetricuncertaintycausedbythepositionalvariationoftheboostvolumeinbreastconservativeradiotherapy AT chuchunnan topologybasedmethodtomitigatethedosimetricuncertaintycausedbythepositionalvariationoftheboostvolumeinbreastconservativeradiotherapy AT hsuhsiuting topologybasedmethodtomitigatethedosimetricuncertaintycausedbythepositionalvariationoftheboostvolumeinbreastconservativeradiotherapy AT liangjian topologybasedmethodtomitigatethedosimetricuncertaintycausedbythepositionalvariationoftheboostvolumeinbreastconservativeradiotherapy AT linyingjun topologybasedmethodtomitigatethedosimetricuncertaintycausedbythepositionalvariationoftheboostvolumeinbreastconservativeradiotherapy AT shiauancheng topologybasedmethodtomitigatethedosimetricuncertaintycausedbythepositionalvariationoftheboostvolumeinbreastconservativeradiotherapy |