Cargando…

Total ankle replacement design and positioning affect implant-bone micromotion and bone strains

Implant loosening – commonly linked with elevated initial micromotion – is the primary indication for total ankle replacement (TAR) revision. Finite element modelling has not been used to assess micromotion of TAR implants; additionally, the biomechanical consequences of TAR malpositioning – previou...

Descripción completa

Detalles Bibliográficos
Autores principales: Sopher, Ran S., Amis, Andrew A., Calder, James D., Jeffers, Jonathan R.T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Butterworth-Heinemann 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5360194/
https://www.ncbi.nlm.nih.gov/pubmed/28233732
http://dx.doi.org/10.1016/j.medengphy.2017.01.022
_version_ 1782516547027206144
author Sopher, Ran S.
Amis, Andrew A.
Calder, James D.
Jeffers, Jonathan R.T.
author_facet Sopher, Ran S.
Amis, Andrew A.
Calder, James D.
Jeffers, Jonathan R.T.
author_sort Sopher, Ran S.
collection PubMed
description Implant loosening – commonly linked with elevated initial micromotion – is the primary indication for total ankle replacement (TAR) revision. Finite element modelling has not been used to assess micromotion of TAR implants; additionally, the biomechanical consequences of TAR malpositioning – previously linked with higher failure rates – remain unexplored. The aim of this study was to estimate implant-bone micromotion and peri-implant bone strains for optimally positioned and malpositioned TAR prostheses, and thereby identify fixation features and malpositioning scenarios increasing the risk of loosening. Finite element models simulating three of the most commonly used TAR devices (BOX(®), Mobility(®) and Salto(®)) implanted into the tibia/talus and subjected to physiological loads were developed. Mobility and Salto demonstrated the largest micromotion of all tibial and talar components, respectively. Any malpositioning of the implant creating a gap between it and the bone resulted in a considerable increase in micromotion and bone strains. It was concluded that better primary stability can be achieved through fixation nearer to the joint line and/or while relying on more than a single peg. Incomplete seating on the bone may result in considerably elevated implant-bone micromotion and bone strains, thereby increasing the risk for TAR failure.
format Online
Article
Text
id pubmed-5360194
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Butterworth-Heinemann
record_format MEDLINE/PubMed
spelling pubmed-53601942017-04-01 Total ankle replacement design and positioning affect implant-bone micromotion and bone strains Sopher, Ran S. Amis, Andrew A. Calder, James D. Jeffers, Jonathan R.T. Med Eng Phys Article Implant loosening – commonly linked with elevated initial micromotion – is the primary indication for total ankle replacement (TAR) revision. Finite element modelling has not been used to assess micromotion of TAR implants; additionally, the biomechanical consequences of TAR malpositioning – previously linked with higher failure rates – remain unexplored. The aim of this study was to estimate implant-bone micromotion and peri-implant bone strains for optimally positioned and malpositioned TAR prostheses, and thereby identify fixation features and malpositioning scenarios increasing the risk of loosening. Finite element models simulating three of the most commonly used TAR devices (BOX(®), Mobility(®) and Salto(®)) implanted into the tibia/talus and subjected to physiological loads were developed. Mobility and Salto demonstrated the largest micromotion of all tibial and talar components, respectively. Any malpositioning of the implant creating a gap between it and the bone resulted in a considerable increase in micromotion and bone strains. It was concluded that better primary stability can be achieved through fixation nearer to the joint line and/or while relying on more than a single peg. Incomplete seating on the bone may result in considerably elevated implant-bone micromotion and bone strains, thereby increasing the risk for TAR failure. Butterworth-Heinemann 2017-04 /pmc/articles/PMC5360194/ /pubmed/28233732 http://dx.doi.org/10.1016/j.medengphy.2017.01.022 Text en © 2017 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sopher, Ran S.
Amis, Andrew A.
Calder, James D.
Jeffers, Jonathan R.T.
Total ankle replacement design and positioning affect implant-bone micromotion and bone strains
title Total ankle replacement design and positioning affect implant-bone micromotion and bone strains
title_full Total ankle replacement design and positioning affect implant-bone micromotion and bone strains
title_fullStr Total ankle replacement design and positioning affect implant-bone micromotion and bone strains
title_full_unstemmed Total ankle replacement design and positioning affect implant-bone micromotion and bone strains
title_short Total ankle replacement design and positioning affect implant-bone micromotion and bone strains
title_sort total ankle replacement design and positioning affect implant-bone micromotion and bone strains
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5360194/
https://www.ncbi.nlm.nih.gov/pubmed/28233732
http://dx.doi.org/10.1016/j.medengphy.2017.01.022
work_keys_str_mv AT sopherrans totalanklereplacementdesignandpositioningaffectimplantbonemicromotionandbonestrains
AT amisandrewa totalanklereplacementdesignandpositioningaffectimplantbonemicromotionandbonestrains
AT calderjamesd totalanklereplacementdesignandpositioningaffectimplantbonemicromotionandbonestrains
AT jeffersjonathanrt totalanklereplacementdesignandpositioningaffectimplantbonemicromotionandbonestrains