Cargando…

The diagnostic accuracy of a laser fluorescence device and digital radiography in detecting approximal caries lesions in posterior permanent teeth: an in vivo study

The aim of this in vivo study was to test the diagnostic accuracy of a pen-type laser fluorescence (LFpen) device in detecting approximal caries lesions, in posterior permanent teeth, at the cavitation and non-cavitation thresholds, and compare it with that of digital bitewing radiography. Thirty pa...

Descripción completa

Detalles Bibliográficos
Autores principales: Menem, R., Barngkgei, I., Beiruti, N., Al Haffar, I., Joury, Easter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer London 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5360861/
https://www.ncbi.nlm.nih.gov/pubmed/28194533
http://dx.doi.org/10.1007/s10103-017-2157-2
_version_ 1782516663153852416
author Menem, R.
Barngkgei, I.
Beiruti, N.
Al Haffar, I.
Joury, Easter
author_facet Menem, R.
Barngkgei, I.
Beiruti, N.
Al Haffar, I.
Joury, Easter
author_sort Menem, R.
collection PubMed
description The aim of this in vivo study was to test the diagnostic accuracy of a pen-type laser fluorescence (LFpen) device in detecting approximal caries lesions, in posterior permanent teeth, at the cavitation and non-cavitation thresholds, and compare it with that of digital bitewing radiography. Thirty patients (aged 18–37), who attended the Faculty of Dentistry at Damascus University for a dental examination, were consecutively screened. Ninety approximal surfaces of posterior permanent teeth without frank cavitations, enamel hypoplasia or restorations were selected and examined using the LFpen (DIAGNOdent pen) and digital bitewing radiography. The reference standard was the visual-tactile inspection, after performing temporary tooth separation, using orthodontic rubber rings, placed for 7 days. The status of included approximal surfaces was recorded as intact/sound, with white/brown spots or cavitated. One trained examiner performed all examinations. There were statistically significant differences in LFpen readings between the three types of approximal surface status (P < 0.001). The optimal cut-off values for detecting approximal caries lesions in posterior permanent teeth were >16 and 8 at the cavitation and non-cavitation thresholds respectively. The sensitivity, specificity and accuracy (measured by the area under the receiver-operating characteristic curve) were 100, 85 and 95 and 92, 90 and 95% at the cavitation and non-cavitation thresholds respectively. The intra-class correlation coefficient for intra-examiner reliability was 0.95. The diagnostic accuracy of the LFpen was significantly higher than that of digital bitewing radiography (P < 0.001). The LFpen’s diagnostic performance was accurate and significantly better than digital bitewing radiography in detecting approximal caries lesions, in posterior permanent teeth. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10103-017-2157-2) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-5360861
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer London
record_format MEDLINE/PubMed
spelling pubmed-53608612017-04-04 The diagnostic accuracy of a laser fluorescence device and digital radiography in detecting approximal caries lesions in posterior permanent teeth: an in vivo study Menem, R. Barngkgei, I. Beiruti, N. Al Haffar, I. Joury, Easter Lasers Med Sci Original Article The aim of this in vivo study was to test the diagnostic accuracy of a pen-type laser fluorescence (LFpen) device in detecting approximal caries lesions, in posterior permanent teeth, at the cavitation and non-cavitation thresholds, and compare it with that of digital bitewing radiography. Thirty patients (aged 18–37), who attended the Faculty of Dentistry at Damascus University for a dental examination, were consecutively screened. Ninety approximal surfaces of posterior permanent teeth without frank cavitations, enamel hypoplasia or restorations were selected and examined using the LFpen (DIAGNOdent pen) and digital bitewing radiography. The reference standard was the visual-tactile inspection, after performing temporary tooth separation, using orthodontic rubber rings, placed for 7 days. The status of included approximal surfaces was recorded as intact/sound, with white/brown spots or cavitated. One trained examiner performed all examinations. There were statistically significant differences in LFpen readings between the three types of approximal surface status (P < 0.001). The optimal cut-off values for detecting approximal caries lesions in posterior permanent teeth were >16 and 8 at the cavitation and non-cavitation thresholds respectively. The sensitivity, specificity and accuracy (measured by the area under the receiver-operating characteristic curve) were 100, 85 and 95 and 92, 90 and 95% at the cavitation and non-cavitation thresholds respectively. The intra-class correlation coefficient for intra-examiner reliability was 0.95. The diagnostic accuracy of the LFpen was significantly higher than that of digital bitewing radiography (P < 0.001). The LFpen’s diagnostic performance was accurate and significantly better than digital bitewing radiography in detecting approximal caries lesions, in posterior permanent teeth. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10103-017-2157-2) contains supplementary material, which is available to authorized users. Springer London 2017-02-14 2017 /pmc/articles/PMC5360861/ /pubmed/28194533 http://dx.doi.org/10.1007/s10103-017-2157-2 Text en © The Author(s) 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Menem, R.
Barngkgei, I.
Beiruti, N.
Al Haffar, I.
Joury, Easter
The diagnostic accuracy of a laser fluorescence device and digital radiography in detecting approximal caries lesions in posterior permanent teeth: an in vivo study
title The diagnostic accuracy of a laser fluorescence device and digital radiography in detecting approximal caries lesions in posterior permanent teeth: an in vivo study
title_full The diagnostic accuracy of a laser fluorescence device and digital radiography in detecting approximal caries lesions in posterior permanent teeth: an in vivo study
title_fullStr The diagnostic accuracy of a laser fluorescence device and digital radiography in detecting approximal caries lesions in posterior permanent teeth: an in vivo study
title_full_unstemmed The diagnostic accuracy of a laser fluorescence device and digital radiography in detecting approximal caries lesions in posterior permanent teeth: an in vivo study
title_short The diagnostic accuracy of a laser fluorescence device and digital radiography in detecting approximal caries lesions in posterior permanent teeth: an in vivo study
title_sort diagnostic accuracy of a laser fluorescence device and digital radiography in detecting approximal caries lesions in posterior permanent teeth: an in vivo study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5360861/
https://www.ncbi.nlm.nih.gov/pubmed/28194533
http://dx.doi.org/10.1007/s10103-017-2157-2
work_keys_str_mv AT menemr thediagnosticaccuracyofalaserfluorescencedeviceanddigitalradiographyindetectingapproximalcarieslesionsinposteriorpermanentteethaninvivostudy
AT barngkgeii thediagnosticaccuracyofalaserfluorescencedeviceanddigitalradiographyindetectingapproximalcarieslesionsinposteriorpermanentteethaninvivostudy
AT beirutin thediagnosticaccuracyofalaserfluorescencedeviceanddigitalradiographyindetectingapproximalcarieslesionsinposteriorpermanentteethaninvivostudy
AT alhaffari thediagnosticaccuracyofalaserfluorescencedeviceanddigitalradiographyindetectingapproximalcarieslesionsinposteriorpermanentteethaninvivostudy
AT jouryeaster thediagnosticaccuracyofalaserfluorescencedeviceanddigitalradiographyindetectingapproximalcarieslesionsinposteriorpermanentteethaninvivostudy
AT menemr diagnosticaccuracyofalaserfluorescencedeviceanddigitalradiographyindetectingapproximalcarieslesionsinposteriorpermanentteethaninvivostudy
AT barngkgeii diagnosticaccuracyofalaserfluorescencedeviceanddigitalradiographyindetectingapproximalcarieslesionsinposteriorpermanentteethaninvivostudy
AT beirutin diagnosticaccuracyofalaserfluorescencedeviceanddigitalradiographyindetectingapproximalcarieslesionsinposteriorpermanentteethaninvivostudy
AT alhaffari diagnosticaccuracyofalaserfluorescencedeviceanddigitalradiographyindetectingapproximalcarieslesionsinposteriorpermanentteethaninvivostudy
AT jouryeaster diagnosticaccuracyofalaserfluorescencedeviceanddigitalradiographyindetectingapproximalcarieslesionsinposteriorpermanentteethaninvivostudy