Cargando…

Self-powered, autonomous Biological Oxygen Demand biosensor for online water quality monitoring

Standard Biological Oxygen Demand (BOD) analysis requires 5 days to complete. To date, microbial fuel cell biosensors used as an alternative method for BOD assessment requires external apparatus, which limits their use for on-line monitoring in remote, off-grid locations. In this study, a self-power...

Descripción completa

Detalles Bibliográficos
Autores principales: Pasternak, Grzegorz, Greenman, John, Ieropoulos, Ioannis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier Sequoia 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5362149/
https://www.ncbi.nlm.nih.gov/pubmed/28579695
http://dx.doi.org/10.1016/j.snb.2017.01.019
_version_ 1782516908976766976
author Pasternak, Grzegorz
Greenman, John
Ieropoulos, Ioannis
author_facet Pasternak, Grzegorz
Greenman, John
Ieropoulos, Ioannis
author_sort Pasternak, Grzegorz
collection PubMed
description Standard Biological Oxygen Demand (BOD) analysis requires 5 days to complete. To date, microbial fuel cell biosensors used as an alternative method for BOD assessment requires external apparatus, which limits their use for on-line monitoring in remote, off-grid locations. In this study, a self-powered, floating biosensor was developed for online water quality monitoring. This approach eliminated the need for external apparatus and maintenance that would otherwise be required by other techniques. The biosensor was able to detect urine in freshwater and turn ON a visual and sound cues (85 dB). The energy needed to operate the biosensor was produced by the system itself with the use of electroactive microorganisms, inside microbial fuel cells. The Chemical Oxygen Demand (COD) was used as a fast method of biosensor validation. When urine concentration exceeded the lower threshold, corresponding to a COD concentration of 57.7 ± 4.8 mgO(2) L(−1), the biosensor turned the alarm ON. The shortest observed actuation time, required to switch ON the alarm was 61 min, when the urine concentration was 149.7 ± 1.7 mgO(2) L(−1). Once the sensor was switched ON, the signal was emitted until the urine organic load decreased to 15.3 ± 1.9 mgO(2) L(−1). When ON, the microbial fuel cell sensor produced a maximum power of 4.3 mW. When switched OFF, the biosensor produced 25.4 μW. The frequency of the signal was proportional to the concentration of urine. The observed frequencies varied between 0.01 and 0.59 Hz. This approach allowed to correlate and quantitatively detect the presence of water contamination, based on signal frequency. The sensor was operating autonomously for 5 months. This is the first report of a self-powered, autonomous device, developed for online water quality monitoring.
format Online
Article
Text
id pubmed-5362149
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier Sequoia
record_format MEDLINE/PubMed
spelling pubmed-53621492017-06-01 Self-powered, autonomous Biological Oxygen Demand biosensor for online water quality monitoring Pasternak, Grzegorz Greenman, John Ieropoulos, Ioannis Sens Actuators B Chem Article Standard Biological Oxygen Demand (BOD) analysis requires 5 days to complete. To date, microbial fuel cell biosensors used as an alternative method for BOD assessment requires external apparatus, which limits their use for on-line monitoring in remote, off-grid locations. In this study, a self-powered, floating biosensor was developed for online water quality monitoring. This approach eliminated the need for external apparatus and maintenance that would otherwise be required by other techniques. The biosensor was able to detect urine in freshwater and turn ON a visual and sound cues (85 dB). The energy needed to operate the biosensor was produced by the system itself with the use of electroactive microorganisms, inside microbial fuel cells. The Chemical Oxygen Demand (COD) was used as a fast method of biosensor validation. When urine concentration exceeded the lower threshold, corresponding to a COD concentration of 57.7 ± 4.8 mgO(2) L(−1), the biosensor turned the alarm ON. The shortest observed actuation time, required to switch ON the alarm was 61 min, when the urine concentration was 149.7 ± 1.7 mgO(2) L(−1). Once the sensor was switched ON, the signal was emitted until the urine organic load decreased to 15.3 ± 1.9 mgO(2) L(−1). When ON, the microbial fuel cell sensor produced a maximum power of 4.3 mW. When switched OFF, the biosensor produced 25.4 μW. The frequency of the signal was proportional to the concentration of urine. The observed frequencies varied between 0.01 and 0.59 Hz. This approach allowed to correlate and quantitatively detect the presence of water contamination, based on signal frequency. The sensor was operating autonomously for 5 months. This is the first report of a self-powered, autonomous device, developed for online water quality monitoring. Elsevier Sequoia 2017-06 /pmc/articles/PMC5362149/ /pubmed/28579695 http://dx.doi.org/10.1016/j.snb.2017.01.019 Text en © 2017 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Pasternak, Grzegorz
Greenman, John
Ieropoulos, Ioannis
Self-powered, autonomous Biological Oxygen Demand biosensor for online water quality monitoring
title Self-powered, autonomous Biological Oxygen Demand biosensor for online water quality monitoring
title_full Self-powered, autonomous Biological Oxygen Demand biosensor for online water quality monitoring
title_fullStr Self-powered, autonomous Biological Oxygen Demand biosensor for online water quality monitoring
title_full_unstemmed Self-powered, autonomous Biological Oxygen Demand biosensor for online water quality monitoring
title_short Self-powered, autonomous Biological Oxygen Demand biosensor for online water quality monitoring
title_sort self-powered, autonomous biological oxygen demand biosensor for online water quality monitoring
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5362149/
https://www.ncbi.nlm.nih.gov/pubmed/28579695
http://dx.doi.org/10.1016/j.snb.2017.01.019
work_keys_str_mv AT pasternakgrzegorz selfpoweredautonomousbiologicaloxygendemandbiosensorforonlinewaterqualitymonitoring
AT greenmanjohn selfpoweredautonomousbiologicaloxygendemandbiosensorforonlinewaterqualitymonitoring
AT ieropoulosioannis selfpoweredautonomousbiologicaloxygendemandbiosensorforonlinewaterqualitymonitoring