Understanding the Complexity of Porous Graphitic Carbon (PGC) Chromatography: Modulation of Mobile-Stationary Phase Interactions Overcomes Loss of Retention and Reduces Variability
[Image: see text] Porous graphitic carbon (PGC) is an important tool in a chromatographer’s armory that retains polar compounds with mass spectrometry (MS)-compatible solvents. However, its applicability is severely limited by an unpredictable loss of retention, which can be attributed to contaminat...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical
Society
2016
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5362737/ https://www.ncbi.nlm.nih.gov/pubmed/27228284 http://dx.doi.org/10.1021/acs.analchem.6b01167 |
_version_ | 1782517015354802176 |
---|---|
author | Bapiro, Tashinga E. Richards, Frances M. Jodrell, Duncan I. |
author_facet | Bapiro, Tashinga E. Richards, Frances M. Jodrell, Duncan I. |
author_sort | Bapiro, Tashinga E. |
collection | PubMed |
description | [Image: see text] Porous graphitic carbon (PGC) is an important tool in a chromatographer’s armory that retains polar compounds with mass spectrometry (MS)-compatible solvents. However, its applicability is severely limited by an unpredictable loss of retention, which can be attributed to contamination. The solutions offered fail to restore the original retention and our observations of retention time shifts of gemcitabine/metabolites on PGC are not consistent with contamination. The mobile phase affects the ionization state of analytes and the polarizable PGC surface that influences the strength of dispersive forces governing retention on the stationary phase. We hypothesized that failure to maintain the same PGC surface before and after running a gradient is a cause of the observed retention loss/variability on PGC. Herein, we optimize the choice of mobile phase solvent in a gradient program with three parts: a preparatory phase, which allows binding of analytes to column; an elution phase, which gives the required separation/peak shape; and a maintenance phase, to preserve the required retention capacity. Via liquid chromatography/tandem mass spectrometry (LC-MS/MS) analysis of gemcitabine and its metabolites extracted from tumor tissue, we demonstrate reproducible chromatography on three PGC columns of different ages. This approach simplifies use of the PGC to the same level as that of a C-18 column, removes the need for column regeneration, and minimizes run times, thus allowing PGC columns to be used to their full potential. |
format | Online Article Text |
id | pubmed-5362737 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | American Chemical
Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-53627372017-03-24 Understanding the Complexity of Porous Graphitic Carbon (PGC) Chromatography: Modulation of Mobile-Stationary Phase Interactions Overcomes Loss of Retention and Reduces Variability Bapiro, Tashinga E. Richards, Frances M. Jodrell, Duncan I. Anal Chem [Image: see text] Porous graphitic carbon (PGC) is an important tool in a chromatographer’s armory that retains polar compounds with mass spectrometry (MS)-compatible solvents. However, its applicability is severely limited by an unpredictable loss of retention, which can be attributed to contamination. The solutions offered fail to restore the original retention and our observations of retention time shifts of gemcitabine/metabolites on PGC are not consistent with contamination. The mobile phase affects the ionization state of analytes and the polarizable PGC surface that influences the strength of dispersive forces governing retention on the stationary phase. We hypothesized that failure to maintain the same PGC surface before and after running a gradient is a cause of the observed retention loss/variability on PGC. Herein, we optimize the choice of mobile phase solvent in a gradient program with three parts: a preparatory phase, which allows binding of analytes to column; an elution phase, which gives the required separation/peak shape; and a maintenance phase, to preserve the required retention capacity. Via liquid chromatography/tandem mass spectrometry (LC-MS/MS) analysis of gemcitabine and its metabolites extracted from tumor tissue, we demonstrate reproducible chromatography on three PGC columns of different ages. This approach simplifies use of the PGC to the same level as that of a C-18 column, removes the need for column regeneration, and minimizes run times, thus allowing PGC columns to be used to their full potential. American Chemical Society 2016-05-26 2016-06-21 /pmc/articles/PMC5362737/ /pubmed/27228284 http://dx.doi.org/10.1021/acs.analchem.6b01167 Text en Copyright © 2016 American Chemical Society This is an open access article published under a Creative Commons Attribution (CC-BY) License (http://pubs.acs.org/page/policy/authorchoice_ccby_termsofuse.html) , which permits unrestricted use, distribution and reproduction in any medium, provided the author and source are cited. |
spellingShingle | Bapiro, Tashinga E. Richards, Frances M. Jodrell, Duncan I. Understanding the Complexity of Porous Graphitic Carbon (PGC) Chromatography: Modulation of Mobile-Stationary Phase Interactions Overcomes Loss of Retention and Reduces Variability |
title | Understanding the Complexity of Porous Graphitic Carbon
(PGC) Chromatography: Modulation of Mobile-Stationary Phase Interactions
Overcomes Loss of Retention and Reduces Variability |
title_full | Understanding the Complexity of Porous Graphitic Carbon
(PGC) Chromatography: Modulation of Mobile-Stationary Phase Interactions
Overcomes Loss of Retention and Reduces Variability |
title_fullStr | Understanding the Complexity of Porous Graphitic Carbon
(PGC) Chromatography: Modulation of Mobile-Stationary Phase Interactions
Overcomes Loss of Retention and Reduces Variability |
title_full_unstemmed | Understanding the Complexity of Porous Graphitic Carbon
(PGC) Chromatography: Modulation of Mobile-Stationary Phase Interactions
Overcomes Loss of Retention and Reduces Variability |
title_short | Understanding the Complexity of Porous Graphitic Carbon
(PGC) Chromatography: Modulation of Mobile-Stationary Phase Interactions
Overcomes Loss of Retention and Reduces Variability |
title_sort | understanding the complexity of porous graphitic carbon
(pgc) chromatography: modulation of mobile-stationary phase interactions
overcomes loss of retention and reduces variability |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5362737/ https://www.ncbi.nlm.nih.gov/pubmed/27228284 http://dx.doi.org/10.1021/acs.analchem.6b01167 |
work_keys_str_mv | AT bapirotashingae understandingthecomplexityofporousgraphiticcarbonpgcchromatographymodulationofmobilestationaryphaseinteractionsovercomeslossofretentionandreducesvariability AT richardsfrancesm understandingthecomplexityofporousgraphiticcarbonpgcchromatographymodulationofmobilestationaryphaseinteractionsovercomeslossofretentionandreducesvariability AT jodrellduncani understandingthecomplexityofporousgraphiticcarbonpgcchromatographymodulationofmobilestationaryphaseinteractionsovercomeslossofretentionandreducesvariability |