PURPOSE: To document the diurnal intraocular pressure (IOP) profile with rebound tonometry performed by primary glaucoma patients in non-clinic environment. PATIENTS AND METHODS: Fifty-three medically-treated eyes of 31 primary angle closure glaucoma (PACG) and 22 primary open angle glaucoma (POAG)...

Descripción completa

Detalles Bibliográficos
Autores principales: Tan, Shaoying, Baig, Nafees, Hansapinyo, Linda, Jhanji, Vishal, Wei, Shihui, Tham, Clement C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5363915/
https://www.ncbi.nlm.nih.gov/pubmed/28333942
http://dx.doi.org/10.1371/journal.pone.0173905
_version_ 1782517233136697344
author Tan, Shaoying
Baig, Nafees
Hansapinyo, Linda
Jhanji, Vishal
Wei, Shihui
Tham, Clement C.
author_facet Tan, Shaoying
Baig, Nafees
Hansapinyo, Linda
Jhanji, Vishal
Wei, Shihui
Tham, Clement C.
author_sort Tan, Shaoying
collection PubMed
description PURPOSE: To document the diurnal intraocular pressure (IOP) profile with rebound tonometry performed by primary glaucoma patients in non-clinic environment. PATIENTS AND METHODS: Fifty-three medically-treated eyes of 31 primary angle closure glaucoma (PACG) and 22 primary open angle glaucoma (POAG) patients with no previous eye surgery were recruited. Diurnal IOP was measured 5 times per day at four-hourly intervals from 08:00 to 24:00 for 1 week in patients’ study eye using rebound tonometry in a non-clinic environment. The diurnal IOP profiles were compared between PACG and POAG eyes. RESULTS: For both PACG and POAG eyes, mean patient-measured IOP was highest in the morning, gradually decreased over the course of a day, and was lowest by midnight (p < 0.001). The diurnal IOP fluctuation ± 1 standard deviation (SD), as documented by SD in daily IOP values, was lower in PACG group (1.6 ± 1.1 mmHg) than in POAG group (2.0 ± 1.2 mmHg; p = 0.049). The mean trough IOP ± 1 SD was higher in PACG group (12.9 ± 2.8 mmHg), compared to POAG group (11.5 ± 3.8 mmHg; p = 0.041). The mean IOP level at midnight ± 1 SD in PACG group (14.0 ± 3.2 mmHg) was higher than that in POAG group (12.1 ± 3.7 mmHg; p = 0.013). CONCLUSIONS: IOP in primary glaucoma patients was highest in the morning, and decreased over the course of a day in non-clinic environment. Treated diurnal IOP fluctuation seemed to be greater in POAG than PACG eyes.
format Online
Article
Text
id pubmed-5363915
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-53639152017-04-06 Comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients Tan, Shaoying Baig, Nafees Hansapinyo, Linda Jhanji, Vishal Wei, Shihui Tham, Clement C. PLoS One Research Article PURPOSE: To document the diurnal intraocular pressure (IOP) profile with rebound tonometry performed by primary glaucoma patients in non-clinic environment. PATIENTS AND METHODS: Fifty-three medically-treated eyes of 31 primary angle closure glaucoma (PACG) and 22 primary open angle glaucoma (POAG) patients with no previous eye surgery were recruited. Diurnal IOP was measured 5 times per day at four-hourly intervals from 08:00 to 24:00 for 1 week in patients’ study eye using rebound tonometry in a non-clinic environment. The diurnal IOP profiles were compared between PACG and POAG eyes. RESULTS: For both PACG and POAG eyes, mean patient-measured IOP was highest in the morning, gradually decreased over the course of a day, and was lowest by midnight (p < 0.001). The diurnal IOP fluctuation ± 1 standard deviation (SD), as documented by SD in daily IOP values, was lower in PACG group (1.6 ± 1.1 mmHg) than in POAG group (2.0 ± 1.2 mmHg; p = 0.049). The mean trough IOP ± 1 SD was higher in PACG group (12.9 ± 2.8 mmHg), compared to POAG group (11.5 ± 3.8 mmHg; p = 0.041). The mean IOP level at midnight ± 1 SD in PACG group (14.0 ± 3.2 mmHg) was higher than that in POAG group (12.1 ± 3.7 mmHg; p = 0.013). CONCLUSIONS: IOP in primary glaucoma patients was highest in the morning, and decreased over the course of a day in non-clinic environment. Treated diurnal IOP fluctuation seemed to be greater in POAG than PACG eyes. Public Library of Science 2017-03-23 /pmc/articles/PMC5363915/ /pubmed/28333942 http://dx.doi.org/10.1371/journal.pone.0173905 Text en © 2017 Tan et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Tan, Shaoying
Baig, Nafees
Hansapinyo, Linda
Jhanji, Vishal
Wei, Shihui
Tham, Clement C.
Comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients
title Comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients
title_full Comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients
title_fullStr Comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients
title_full_unstemmed Comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients
title_short Comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients
title_sort comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5363915/
https://www.ncbi.nlm.nih.gov/pubmed/28333942
http://dx.doi.org/10.1371/journal.pone.0173905
work_keys_str_mv AT tanshaoying comparisonofselfmeasureddiurnalintraocularpressureprofilesusingreboundtonometrybetweenprimaryangleclosureglaucomaandprimaryopenangleglaucomapatients
AT baignafees comparisonofselfmeasureddiurnalintraocularpressureprofilesusingreboundtonometrybetweenprimaryangleclosureglaucomaandprimaryopenangleglaucomapatients
AT hansapinyolinda comparisonofselfmeasureddiurnalintraocularpressureprofilesusingreboundtonometrybetweenprimaryangleclosureglaucomaandprimaryopenangleglaucomapatients
AT jhanjivishal comparisonofselfmeasureddiurnalintraocularpressureprofilesusingreboundtonometrybetweenprimaryangleclosureglaucomaandprimaryopenangleglaucomapatients
AT weishihui comparisonofselfmeasureddiurnalintraocularpressureprofilesusingreboundtonometrybetweenprimaryangleclosureglaucomaandprimaryopenangleglaucomapatients
AT thamclementc comparisonofselfmeasureddiurnalintraocularpressureprofilesusingreboundtonometrybetweenprimaryangleclosureglaucomaandprimaryopenangleglaucomapatients