Cargando…
Exposure of Titanium Mesh after Cranioplasty for Microvascular Decompression Surgery: Two Case Reports
Two cases of exposed titanium mesh occurred after implantation for cranioplasty after repeated procedures for microvascular decompression (MVD). Case 1 was a 62-year-old female who underwent MVD for left hemifacial spasm followed by repair of cerebrospinal fluid leak after the surgery, and Case 2 wa...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japan Neurosurgical Society
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5364882/ https://www.ncbi.nlm.nih.gov/pubmed/28663983 http://dx.doi.org/10.2176/nmccrj.2014-0444 |
_version_ | 1782517413352308736 |
---|---|
author | Watanabe, Saiko Amagasaki, Kenichi Naemura, Kazuaki Nakaguchi, Hiroshi |
author_facet | Watanabe, Saiko Amagasaki, Kenichi Naemura, Kazuaki Nakaguchi, Hiroshi |
author_sort | Watanabe, Saiko |
collection | PubMed |
description | Two cases of exposed titanium mesh occurred after implantation for cranioplasty after repeated procedures for microvascular decompression (MVD). Case 1 was a 62-year-old female who underwent MVD for left hemifacial spasm followed by repair of cerebrospinal fluid leak after the surgery, and Case 2 was a 75-year-old female who underwent MVD twice for right trigeminal neuralgia. Both patients visited our hospital again with complaints of postauricular lesion. Titanium mesh was visible through the operative scar and was successfully removed with no complication in both cases. Both patients were underweight females, and combined with multistep surgery may have contributed to the pathology. The present cases suggest that use of titanium mesh should be avoided for cranioplasty of posterior fossa surgery, especially for repeated procedures. |
format | Online Article Text |
id | pubmed-5364882 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Japan Neurosurgical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-53648822017-06-29 Exposure of Titanium Mesh after Cranioplasty for Microvascular Decompression Surgery: Two Case Reports Watanabe, Saiko Amagasaki, Kenichi Naemura, Kazuaki Nakaguchi, Hiroshi NMC Case Rep J Case Report Two cases of exposed titanium mesh occurred after implantation for cranioplasty after repeated procedures for microvascular decompression (MVD). Case 1 was a 62-year-old female who underwent MVD for left hemifacial spasm followed by repair of cerebrospinal fluid leak after the surgery, and Case 2 was a 75-year-old female who underwent MVD twice for right trigeminal neuralgia. Both patients visited our hospital again with complaints of postauricular lesion. Titanium mesh was visible through the operative scar and was successfully removed with no complication in both cases. Both patients were underweight females, and combined with multistep surgery may have contributed to the pathology. The present cases suggest that use of titanium mesh should be avoided for cranioplasty of posterior fossa surgery, especially for repeated procedures. The Japan Neurosurgical Society 2015-09-03 /pmc/articles/PMC5364882/ /pubmed/28663983 http://dx.doi.org/10.2176/nmccrj.2014-0444 Text en © 2015 The Japan Neurosurgical Society This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/ |
spellingShingle | Case Report Watanabe, Saiko Amagasaki, Kenichi Naemura, Kazuaki Nakaguchi, Hiroshi Exposure of Titanium Mesh after Cranioplasty for Microvascular Decompression Surgery: Two Case Reports |
title | Exposure of Titanium Mesh after Cranioplasty for Microvascular Decompression Surgery: Two Case Reports |
title_full | Exposure of Titanium Mesh after Cranioplasty for Microvascular Decompression Surgery: Two Case Reports |
title_fullStr | Exposure of Titanium Mesh after Cranioplasty for Microvascular Decompression Surgery: Two Case Reports |
title_full_unstemmed | Exposure of Titanium Mesh after Cranioplasty for Microvascular Decompression Surgery: Two Case Reports |
title_short | Exposure of Titanium Mesh after Cranioplasty for Microvascular Decompression Surgery: Two Case Reports |
title_sort | exposure of titanium mesh after cranioplasty for microvascular decompression surgery: two case reports |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5364882/ https://www.ncbi.nlm.nih.gov/pubmed/28663983 http://dx.doi.org/10.2176/nmccrj.2014-0444 |
work_keys_str_mv | AT watanabesaiko exposureoftitaniummeshaftercranioplastyformicrovasculardecompressionsurgerytwocasereports AT amagasakikenichi exposureoftitaniummeshaftercranioplastyformicrovasculardecompressionsurgerytwocasereports AT naemurakazuaki exposureoftitaniummeshaftercranioplastyformicrovasculardecompressionsurgerytwocasereports AT nakaguchihiroshi exposureoftitaniummeshaftercranioplastyformicrovasculardecompressionsurgerytwocasereports |