Cargando…

Exposure of Titanium Mesh after Cranioplasty for Microvascular Decompression Surgery: Two Case Reports

Two cases of exposed titanium mesh occurred after implantation for cranioplasty after repeated procedures for microvascular decompression (MVD). Case 1 was a 62-year-old female who underwent MVD for left hemifacial spasm followed by repair of cerebrospinal fluid leak after the surgery, and Case 2 wa...

Descripción completa

Detalles Bibliográficos
Autores principales: Watanabe, Saiko, Amagasaki, Kenichi, Naemura, Kazuaki, Nakaguchi, Hiroshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japan Neurosurgical Society 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5364882/
https://www.ncbi.nlm.nih.gov/pubmed/28663983
http://dx.doi.org/10.2176/nmccrj.2014-0444
_version_ 1782517413352308736
author Watanabe, Saiko
Amagasaki, Kenichi
Naemura, Kazuaki
Nakaguchi, Hiroshi
author_facet Watanabe, Saiko
Amagasaki, Kenichi
Naemura, Kazuaki
Nakaguchi, Hiroshi
author_sort Watanabe, Saiko
collection PubMed
description Two cases of exposed titanium mesh occurred after implantation for cranioplasty after repeated procedures for microvascular decompression (MVD). Case 1 was a 62-year-old female who underwent MVD for left hemifacial spasm followed by repair of cerebrospinal fluid leak after the surgery, and Case 2 was a 75-year-old female who underwent MVD twice for right trigeminal neuralgia. Both patients visited our hospital again with complaints of postauricular lesion. Titanium mesh was visible through the operative scar and was successfully removed with no complication in both cases. Both patients were underweight females, and combined with multistep surgery may have contributed to the pathology. The present cases suggest that use of titanium mesh should be avoided for cranioplasty of posterior fossa surgery, especially for repeated procedures.
format Online
Article
Text
id pubmed-5364882
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher The Japan Neurosurgical Society
record_format MEDLINE/PubMed
spelling pubmed-53648822017-06-29 Exposure of Titanium Mesh after Cranioplasty for Microvascular Decompression Surgery: Two Case Reports Watanabe, Saiko Amagasaki, Kenichi Naemura, Kazuaki Nakaguchi, Hiroshi NMC Case Rep J Case Report Two cases of exposed titanium mesh occurred after implantation for cranioplasty after repeated procedures for microvascular decompression (MVD). Case 1 was a 62-year-old female who underwent MVD for left hemifacial spasm followed by repair of cerebrospinal fluid leak after the surgery, and Case 2 was a 75-year-old female who underwent MVD twice for right trigeminal neuralgia. Both patients visited our hospital again with complaints of postauricular lesion. Titanium mesh was visible through the operative scar and was successfully removed with no complication in both cases. Both patients were underweight females, and combined with multistep surgery may have contributed to the pathology. The present cases suggest that use of titanium mesh should be avoided for cranioplasty of posterior fossa surgery, especially for repeated procedures. The Japan Neurosurgical Society 2015-09-03 /pmc/articles/PMC5364882/ /pubmed/28663983 http://dx.doi.org/10.2176/nmccrj.2014-0444 Text en © 2015 The Japan Neurosurgical Society This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Case Report
Watanabe, Saiko
Amagasaki, Kenichi
Naemura, Kazuaki
Nakaguchi, Hiroshi
Exposure of Titanium Mesh after Cranioplasty for Microvascular Decompression Surgery: Two Case Reports
title Exposure of Titanium Mesh after Cranioplasty for Microvascular Decompression Surgery: Two Case Reports
title_full Exposure of Titanium Mesh after Cranioplasty for Microvascular Decompression Surgery: Two Case Reports
title_fullStr Exposure of Titanium Mesh after Cranioplasty for Microvascular Decompression Surgery: Two Case Reports
title_full_unstemmed Exposure of Titanium Mesh after Cranioplasty for Microvascular Decompression Surgery: Two Case Reports
title_short Exposure of Titanium Mesh after Cranioplasty for Microvascular Decompression Surgery: Two Case Reports
title_sort exposure of titanium mesh after cranioplasty for microvascular decompression surgery: two case reports
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5364882/
https://www.ncbi.nlm.nih.gov/pubmed/28663983
http://dx.doi.org/10.2176/nmccrj.2014-0444
work_keys_str_mv AT watanabesaiko exposureoftitaniummeshaftercranioplastyformicrovasculardecompressionsurgerytwocasereports
AT amagasakikenichi exposureoftitaniummeshaftercranioplastyformicrovasculardecompressionsurgerytwocasereports
AT naemurakazuaki exposureoftitaniummeshaftercranioplastyformicrovasculardecompressionsurgerytwocasereports
AT nakaguchihiroshi exposureoftitaniummeshaftercranioplastyformicrovasculardecompressionsurgerytwocasereports