Cargando…

Baricity of Bupivacaine on Maternal Hemodynamics after Spinal Anesthesia for Cesarean Section: A Randomized Controlled Trial

BACKGROUND: After spinal anesthesia, patients undergoing cesarean section are more likely to develop hemodynamic changes. The baricity of local anesthetic has an important role on spinal blockade effects. The aim of this study was to compare the isobar and hyperbaric bupivacaine 0.5% plus fentanyl o...

Descripción completa

Detalles Bibliográficos
Autores principales: Atashkhoei, Simin, Abedini, Naghi, Pourfathi, Hojjat, Znoz, Ali Bahrami, Marandi, Pouya Hatami
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Iranian Journal of Medical Sciences 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5366361/
https://www.ncbi.nlm.nih.gov/pubmed/28360439
_version_ 1782517577246834688
author Atashkhoei, Simin
Abedini, Naghi
Pourfathi, Hojjat
Znoz, Ali Bahrami
Marandi, Pouya Hatami
author_facet Atashkhoei, Simin
Abedini, Naghi
Pourfathi, Hojjat
Znoz, Ali Bahrami
Marandi, Pouya Hatami
author_sort Atashkhoei, Simin
collection PubMed
description BACKGROUND: After spinal anesthesia, patients undergoing cesarean section are more likely to develop hemodynamic changes. The baricity of local anesthetic has an important role on spinal blockade effects. The aim of this study was to compare the isobar and hyperbaric bupivacaine 0.5% plus fentanyl on maternal hemodynamics after spinal anesthesia for C/S. METHODS: In this double-blind study, 84 healthy pregnant women undergoing C/S using bupivacaine 0.5% isobar (study group, n=42) or hyperbaric (control group, n=42) for spinal anesthesia were scheduled. The study was conducted from 21 April 2014 to 21 November 2014 at Al-Zahra Hospital, Tabriz, Iran. Parameters such as maternal hemodynamics, block characteristics, side effects, and neonatal Apgar scores were recorded. Data were analyzed using the SPSS software by performing chi-square test, Fisher’s exact test, one-way ANOVA, Mann-Whitney U-test, and student’s t test. RESULTS: The incidence of hypotension in the isobar group was lower than the hyperbaric group, although it was not statistically significant (40.47% vs. 61.9%, P=0.08). The duration of hypotension was shorter in the study group (1.6±7.8 min vs. 7.4±12.5 min, P=0.004). The dose of ephedrine was lower in the study group (2.4±6.6 mg vs. 5.3±10.7 mg, P=0.006). The main maternal side effect is sustained hypotension that was seen in 0 patients of the isobar and 7 (16.66%) of hyperbaric groups (P=0.006). None of the neonates had Apgar score≤7 at 5 min of delivery (P=1.0). Sensory and motor block duration was shorter in the study group (P=0.01). CONCLUSION: Isobaric bupivacaine is associated with more hemodynamic stability and shorter sensory and motor blockade in mothers under spinal anesthesia for C/S. Trial Registration Number: IRCT201401287013N7
format Online
Article
Text
id pubmed-5366361
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Iranian Journal of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-53663612017-03-30 Baricity of Bupivacaine on Maternal Hemodynamics after Spinal Anesthesia for Cesarean Section: A Randomized Controlled Trial Atashkhoei, Simin Abedini, Naghi Pourfathi, Hojjat Znoz, Ali Bahrami Marandi, Pouya Hatami Iran J Med Sci Original Article BACKGROUND: After spinal anesthesia, patients undergoing cesarean section are more likely to develop hemodynamic changes. The baricity of local anesthetic has an important role on spinal blockade effects. The aim of this study was to compare the isobar and hyperbaric bupivacaine 0.5% plus fentanyl on maternal hemodynamics after spinal anesthesia for C/S. METHODS: In this double-blind study, 84 healthy pregnant women undergoing C/S using bupivacaine 0.5% isobar (study group, n=42) or hyperbaric (control group, n=42) for spinal anesthesia were scheduled. The study was conducted from 21 April 2014 to 21 November 2014 at Al-Zahra Hospital, Tabriz, Iran. Parameters such as maternal hemodynamics, block characteristics, side effects, and neonatal Apgar scores were recorded. Data were analyzed using the SPSS software by performing chi-square test, Fisher’s exact test, one-way ANOVA, Mann-Whitney U-test, and student’s t test. RESULTS: The incidence of hypotension in the isobar group was lower than the hyperbaric group, although it was not statistically significant (40.47% vs. 61.9%, P=0.08). The duration of hypotension was shorter in the study group (1.6±7.8 min vs. 7.4±12.5 min, P=0.004). The dose of ephedrine was lower in the study group (2.4±6.6 mg vs. 5.3±10.7 mg, P=0.006). The main maternal side effect is sustained hypotension that was seen in 0 patients of the isobar and 7 (16.66%) of hyperbaric groups (P=0.006). None of the neonates had Apgar score≤7 at 5 min of delivery (P=1.0). Sensory and motor block duration was shorter in the study group (P=0.01). CONCLUSION: Isobaric bupivacaine is associated with more hemodynamic stability and shorter sensory and motor blockade in mothers under spinal anesthesia for C/S. Trial Registration Number: IRCT201401287013N7 Iranian Journal of Medical Sciences 2017-03 /pmc/articles/PMC5366361/ /pubmed/28360439 Text en Copyright: © Iranian Journal of Medical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Atashkhoei, Simin
Abedini, Naghi
Pourfathi, Hojjat
Znoz, Ali Bahrami
Marandi, Pouya Hatami
Baricity of Bupivacaine on Maternal Hemodynamics after Spinal Anesthesia for Cesarean Section: A Randomized Controlled Trial
title Baricity of Bupivacaine on Maternal Hemodynamics after Spinal Anesthesia for Cesarean Section: A Randomized Controlled Trial
title_full Baricity of Bupivacaine on Maternal Hemodynamics after Spinal Anesthesia for Cesarean Section: A Randomized Controlled Trial
title_fullStr Baricity of Bupivacaine on Maternal Hemodynamics after Spinal Anesthesia for Cesarean Section: A Randomized Controlled Trial
title_full_unstemmed Baricity of Bupivacaine on Maternal Hemodynamics after Spinal Anesthesia for Cesarean Section: A Randomized Controlled Trial
title_short Baricity of Bupivacaine on Maternal Hemodynamics after Spinal Anesthesia for Cesarean Section: A Randomized Controlled Trial
title_sort baricity of bupivacaine on maternal hemodynamics after spinal anesthesia for cesarean section: a randomized controlled trial
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5366361/
https://www.ncbi.nlm.nih.gov/pubmed/28360439
work_keys_str_mv AT atashkhoeisimin baricityofbupivacaineonmaternalhemodynamicsafterspinalanesthesiaforcesareansectionarandomizedcontrolledtrial
AT abedininaghi baricityofbupivacaineonmaternalhemodynamicsafterspinalanesthesiaforcesareansectionarandomizedcontrolledtrial
AT pourfathihojjat baricityofbupivacaineonmaternalhemodynamicsafterspinalanesthesiaforcesareansectionarandomizedcontrolledtrial
AT znozalibahrami baricityofbupivacaineonmaternalhemodynamicsafterspinalanesthesiaforcesareansectionarandomizedcontrolledtrial
AT marandipouyahatami baricityofbupivacaineonmaternalhemodynamicsafterspinalanesthesiaforcesareansectionarandomizedcontrolledtrial