Cargando…

Good Early Results Obtained with a Guided-Motion Implant for Total Knee Arthroplasty: A Consecutive Case Series

BACKGROUND: Previous studies have shown a high incidence of complications with a bi-cruciate stabilized (BCS) guided-motion total knee arthroplasty (TKA) design, which led to recent modifications of the design by the manufacturer. OBJECTIVE: The current study was undertaken to assess whether the use...

Descripción completa

Detalles Bibliográficos
Autores principales: Hommel, Hagen, Wilke, Kai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bentham Open 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5366378/
https://www.ncbi.nlm.nih.gov/pubmed/28400873
http://dx.doi.org/10.2174/1874325001711010051
_version_ 1782517581191577600
author Hommel, Hagen
Wilke, Kai
author_facet Hommel, Hagen
Wilke, Kai
author_sort Hommel, Hagen
collection PubMed
description BACKGROUND: Previous studies have shown a high incidence of complications with a bi-cruciate stabilized (BCS) guided-motion total knee arthroplasty (TKA) design, which led to recent modifications of the design by the manufacturer. OBJECTIVE: The current study was undertaken to assess whether the use of this TKA system with an extension-first surgical technique is associated with a similar rate of short-term adverse outcome as reported in literature. MATERIAL AND METHODS: This retrospective study enrolled 257 consecutive patients (257 knees) undergoing TKA for osteoarthritis of the knee, with the first 153 receiving cemented Journey BCS I implants and the remaining 104 receiving cemented Journey BCS II implants when these became available. RESULTS: Mean follow-up time for the cohort was 24.5 ± 7.8 months (range, 12 - 36 months). There were no cases of stiffness. Incidence of iliotibial friction syndrome was considered low: three (2.0%) knees in the BCS I group and two (1.9%) in the BCS II group (p = 0.676). Five (2.5%) knees presented with mild instability in midflexion, three (2.0%) in the BCS I group and two (1.9%) in the BCS II group (p = 0.676). One patient with a BCS I implant required reoperation for aseptic loosening 23 months postoperatively. At one-year follow-up, there were no clinically relevant differences in any of the clinical outcomes. CONCLUSION: When used in combination with an extension-first surgical technique, good early functional results with an acceptable rate of complications were obtained with both the original and the updated Journey BCS knee implant.
format Online
Article
Text
id pubmed-5366378
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-53663782017-04-11 Good Early Results Obtained with a Guided-Motion Implant for Total Knee Arthroplasty: A Consecutive Case Series Hommel, Hagen Wilke, Kai Open Orthop J Article BACKGROUND: Previous studies have shown a high incidence of complications with a bi-cruciate stabilized (BCS) guided-motion total knee arthroplasty (TKA) design, which led to recent modifications of the design by the manufacturer. OBJECTIVE: The current study was undertaken to assess whether the use of this TKA system with an extension-first surgical technique is associated with a similar rate of short-term adverse outcome as reported in literature. MATERIAL AND METHODS: This retrospective study enrolled 257 consecutive patients (257 knees) undergoing TKA for osteoarthritis of the knee, with the first 153 receiving cemented Journey BCS I implants and the remaining 104 receiving cemented Journey BCS II implants when these became available. RESULTS: Mean follow-up time for the cohort was 24.5 ± 7.8 months (range, 12 - 36 months). There were no cases of stiffness. Incidence of iliotibial friction syndrome was considered low: three (2.0%) knees in the BCS I group and two (1.9%) in the BCS II group (p = 0.676). Five (2.5%) knees presented with mild instability in midflexion, three (2.0%) in the BCS I group and two (1.9%) in the BCS II group (p = 0.676). One patient with a BCS I implant required reoperation for aseptic loosening 23 months postoperatively. At one-year follow-up, there were no clinically relevant differences in any of the clinical outcomes. CONCLUSION: When used in combination with an extension-first surgical technique, good early functional results with an acceptable rate of complications were obtained with both the original and the updated Journey BCS knee implant. Bentham Open 2017-02-24 /pmc/articles/PMC5366378/ /pubmed/28400873 http://dx.doi.org/10.2174/1874325001711010051 Text en © 2017 Hommel and Wilke https://creativecommons.org/licenses/by/4.0/legalcode This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: https://creativecommons.org/licenses/by/4.0/legalcode. This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Article
Hommel, Hagen
Wilke, Kai
Good Early Results Obtained with a Guided-Motion Implant for Total Knee Arthroplasty: A Consecutive Case Series
title Good Early Results Obtained with a Guided-Motion Implant for Total Knee Arthroplasty: A Consecutive Case Series
title_full Good Early Results Obtained with a Guided-Motion Implant for Total Knee Arthroplasty: A Consecutive Case Series
title_fullStr Good Early Results Obtained with a Guided-Motion Implant for Total Knee Arthroplasty: A Consecutive Case Series
title_full_unstemmed Good Early Results Obtained with a Guided-Motion Implant for Total Knee Arthroplasty: A Consecutive Case Series
title_short Good Early Results Obtained with a Guided-Motion Implant for Total Knee Arthroplasty: A Consecutive Case Series
title_sort good early results obtained with a guided-motion implant for total knee arthroplasty: a consecutive case series
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5366378/
https://www.ncbi.nlm.nih.gov/pubmed/28400873
http://dx.doi.org/10.2174/1874325001711010051
work_keys_str_mv AT hommelhagen goodearlyresultsobtainedwithaguidedmotionimplantfortotalkneearthroplastyaconsecutivecaseseries
AT wilkekai goodearlyresultsobtainedwithaguidedmotionimplantfortotalkneearthroplastyaconsecutivecaseseries