Temporal regularization of ultrasound‐based liver motion estimation for image‐guided radiation therapy

PURPOSE: Ultrasound‐based motion estimation is an expanding subfield of image‐guided radiation therapy. Although ultrasound can detect tissue motion that is a fraction of a millimeter, its accuracy is variable. For controlling linear accelerator tracking and gating, ultrasound motion estimates must...

Descripción completa

Detalles Bibliográficos
Autores principales: O'Shea, Tuathan P., Bamber, Jeffrey C., Harris, Emma J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Association of Physicists in Medicine 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5366873/
https://www.ncbi.nlm.nih.gov/pubmed/26745938
http://dx.doi.org/10.1118/1.4938582
_version_ 1782517671834681344
author O'Shea, Tuathan P.
Bamber, Jeffrey C.
Harris, Emma J.
author_facet O'Shea, Tuathan P.
Bamber, Jeffrey C.
Harris, Emma J.
author_sort O'Shea, Tuathan P.
collection PubMed
description PURPOSE: Ultrasound‐based motion estimation is an expanding subfield of image‐guided radiation therapy. Although ultrasound can detect tissue motion that is a fraction of a millimeter, its accuracy is variable. For controlling linear accelerator tracking and gating, ultrasound motion estimates must remain highly accurate throughout the imaging sequence. This study presents a temporal regularization method for correlation‐based template matching which aims to improve the accuracy of motion estimates. METHODS: Liver ultrasound sequences (15–23 Hz imaging rate, 2.5–5.5 min length) from ten healthy volunteers under free breathing were used. Anatomical features (blood vessels) in each sequence were manually annotated for comparison with normalized cross‐correlation based template matching. Five sequences from a Siemens Acuson™ scanner were used for algorithm development (training set). Results from incremental tracking (IT) were compared with a temporal regularization method, which included a highly specific similarity metric and state observer, known as the α–β filter/similarity threshold (ABST). A further five sequences from an Elekta Clarity™ system were used for validation, without alteration of the tracking algorithm (validation set). RESULTS: Overall, the ABST method produced marked improvements in vessel tracking accuracy. For the training set, the mean and 95th percentile (95%) errors (defined as the difference from manual annotations) were 1.6 and 1.4 mm, respectively (compared to 6.2 and 9.1 mm, respectively, for IT). For each sequence, the use of the state observer leads to improvement in the 95% error. For the validation set, the mean and 95% errors for the ABST method were 0.8 and 1.5 mm, respectively. CONCLUSIONS: Ultrasound‐based motion estimation has potential to monitor liver translation over long time periods with high accuracy. Nonrigid motion (strain) and the quality of the ultrasound data are likely to have an impact on tracking performance. A future study will investigate spatial uniformity of motion and its effect on the motion estimation errors.
format Online
Article
Text
id pubmed-5366873
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher American Association of Physicists in Medicine
record_format MEDLINE/PubMed
spelling pubmed-53668732017-04-10 Temporal regularization of ultrasound‐based liver motion estimation for image‐guided radiation therapy O'Shea, Tuathan P. Bamber, Jeffrey C. Harris, Emma J. Med Phys Therapeutic Interventions PURPOSE: Ultrasound‐based motion estimation is an expanding subfield of image‐guided radiation therapy. Although ultrasound can detect tissue motion that is a fraction of a millimeter, its accuracy is variable. For controlling linear accelerator tracking and gating, ultrasound motion estimates must remain highly accurate throughout the imaging sequence. This study presents a temporal regularization method for correlation‐based template matching which aims to improve the accuracy of motion estimates. METHODS: Liver ultrasound sequences (15–23 Hz imaging rate, 2.5–5.5 min length) from ten healthy volunteers under free breathing were used. Anatomical features (blood vessels) in each sequence were manually annotated for comparison with normalized cross‐correlation based template matching. Five sequences from a Siemens Acuson™ scanner were used for algorithm development (training set). Results from incremental tracking (IT) were compared with a temporal regularization method, which included a highly specific similarity metric and state observer, known as the α–β filter/similarity threshold (ABST). A further five sequences from an Elekta Clarity™ system were used for validation, without alteration of the tracking algorithm (validation set). RESULTS: Overall, the ABST method produced marked improvements in vessel tracking accuracy. For the training set, the mean and 95th percentile (95%) errors (defined as the difference from manual annotations) were 1.6 and 1.4 mm, respectively (compared to 6.2 and 9.1 mm, respectively, for IT). For each sequence, the use of the state observer leads to improvement in the 95% error. For the validation set, the mean and 95% errors for the ABST method were 0.8 and 1.5 mm, respectively. CONCLUSIONS: Ultrasound‐based motion estimation has potential to monitor liver translation over long time periods with high accuracy. Nonrigid motion (strain) and the quality of the ultrasound data are likely to have an impact on tracking performance. A future study will investigate spatial uniformity of motion and its effect on the motion estimation errors. American Association of Physicists in Medicine 2016-11-30 2016-01 /pmc/articles/PMC5366873/ /pubmed/26745938 http://dx.doi.org/10.1118/1.4938582 Text en © 2016 The Authors. Published by American Association of Physicists in Medicine and John Wiley & Sons Ltd. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Therapeutic Interventions
O'Shea, Tuathan P.
Bamber, Jeffrey C.
Harris, Emma J.
Temporal regularization of ultrasound‐based liver motion estimation for image‐guided radiation therapy
title Temporal regularization of ultrasound‐based liver motion estimation for image‐guided radiation therapy
title_full Temporal regularization of ultrasound‐based liver motion estimation for image‐guided radiation therapy
title_fullStr Temporal regularization of ultrasound‐based liver motion estimation for image‐guided radiation therapy
title_full_unstemmed Temporal regularization of ultrasound‐based liver motion estimation for image‐guided radiation therapy
title_short Temporal regularization of ultrasound‐based liver motion estimation for image‐guided radiation therapy
title_sort temporal regularization of ultrasound‐based liver motion estimation for image‐guided radiation therapy
topic Therapeutic Interventions
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5366873/
https://www.ncbi.nlm.nih.gov/pubmed/26745938
http://dx.doi.org/10.1118/1.4938582
work_keys_str_mv AT osheatuathanp temporalregularizationofultrasoundbasedlivermotionestimationforimageguidedradiationtherapy
AT bamberjeffreyc temporalregularizationofultrasoundbasedlivermotionestimationforimageguidedradiationtherapy
AT harrisemmaj temporalregularizationofultrasoundbasedlivermotionestimationforimageguidedradiationtherapy