PURPOSE: A mathematical simulation of stress distribution around orbital implants was used to determine which length and diameter of implants would be best to dissipate stress. METHODS: An integrated system for computed tomography data was utilized to create a 3-dimensional model of craniofacial str...

Descripción completa

Detalles Bibliográficos
Autores principales: Xing, Zhang, Chen, Ling Song, Peng, Wei, Chen, Ling Jian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5367500/
https://www.ncbi.nlm.nih.gov/pubmed/28005657
http://dx.doi.org/10.1097/SCS.0000000000003305
_version_ 1782517782236102656
author Xing, Zhang
Chen, Ling Song
Peng, Wei
Chen, Ling Jian
author_facet Xing, Zhang
Chen, Ling Song
Peng, Wei
Chen, Ling Jian
author_sort Xing, Zhang
collection PubMed
description PURPOSE: A mathematical simulation of stress distribution around orbital implants was used to determine which length and diameter of implants would be best to dissipate stress. METHODS: An integrated system for computed tomography data was utilized to create a 3-dimensional model of craniofacial structures. The model simulated implants placed in the 7, 11, and 12 o’clock positions of the orbital rim. A load of 2 N was applied to the model along the long axis of the implant (model 1) and an angle of 45° with the long axis of the implant (model 2). A model simulating an implant with a diameter of 3.75 mm and lengths of 3, 4, 6, 8, and 10 mm was developed to investigate the influence of the length factor. The influence of different diameters was modeled using implants with a length of 6 mm and diameters of 3.0, 3.75, 4.2, 5.0, and 6.0 mm. Values of von Mises equivalent stress at the implant–bone interface were computed using the finite element analysis for all variations. RESULTS: The elements exposed to the maximum stress were located around the root of the orbital implant in model 1 or between the neck and the first thread of the orbital implant in model 2. An increase in the orbital implant diameter led to a decrease in the maximum von Mises equivalent stress values. In model 1, the reductions were 45.2% (diameter of 3.0–3.75 mm), 25.3% (diameter of 3.75–4.2 mm), 17.2% (diameter of 4.2–5.0 mm), and 5.4% (diameter of 5.0–6.0 mm). In model 2, the reductions of the maximum stress values were 51.9%, 35.4%, 19.7%, and 8.1% respectively. However, the influence of orbital implant length was not as pronounced as that of diameter. In model 1, the reductions were 28.8% (length of 3–4 mm), 19.2% (length of 4–6 mm), 9.6% (length of 6–8 mm), and 4.3% (length of 8–10 mm). In model 2, the reductions of the maximum stress values were 35.5%, 21.1%, 10.9%, and 5.4% respectively. CONCLUSIONS: An increase in the implant diameter decreased the maximum von Mises equivalent stress around the orbital implant more than an increase in the implant length. From a biomechanical perspective, the optimum choice was an orbital implant with no less than 4.2 mm diameter allowed by the anatomy.
format Online
Article
Text
id pubmed-5367500
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-53675002017-04-07 Influence of Orbital Implant Length and Diameter on Stress Distribution: A Finite Element Analysis Xing, Zhang Chen, Ling Song Peng, Wei Chen, Ling Jian J Craniofac Surg Brief Clinical Studies PURPOSE: A mathematical simulation of stress distribution around orbital implants was used to determine which length and diameter of implants would be best to dissipate stress. METHODS: An integrated system for computed tomography data was utilized to create a 3-dimensional model of craniofacial structures. The model simulated implants placed in the 7, 11, and 12 o’clock positions of the orbital rim. A load of 2 N was applied to the model along the long axis of the implant (model 1) and an angle of 45° with the long axis of the implant (model 2). A model simulating an implant with a diameter of 3.75 mm and lengths of 3, 4, 6, 8, and 10 mm was developed to investigate the influence of the length factor. The influence of different diameters was modeled using implants with a length of 6 mm and diameters of 3.0, 3.75, 4.2, 5.0, and 6.0 mm. Values of von Mises equivalent stress at the implant–bone interface were computed using the finite element analysis for all variations. RESULTS: The elements exposed to the maximum stress were located around the root of the orbital implant in model 1 or between the neck and the first thread of the orbital implant in model 2. An increase in the orbital implant diameter led to a decrease in the maximum von Mises equivalent stress values. In model 1, the reductions were 45.2% (diameter of 3.0–3.75 mm), 25.3% (diameter of 3.75–4.2 mm), 17.2% (diameter of 4.2–5.0 mm), and 5.4% (diameter of 5.0–6.0 mm). In model 2, the reductions of the maximum stress values were 51.9%, 35.4%, 19.7%, and 8.1% respectively. However, the influence of orbital implant length was not as pronounced as that of diameter. In model 1, the reductions were 28.8% (length of 3–4 mm), 19.2% (length of 4–6 mm), 9.6% (length of 6–8 mm), and 4.3% (length of 8–10 mm). In model 2, the reductions of the maximum stress values were 35.5%, 21.1%, 10.9%, and 5.4% respectively. CONCLUSIONS: An increase in the implant diameter decreased the maximum von Mises equivalent stress around the orbital implant more than an increase in the implant length. From a biomechanical perspective, the optimum choice was an orbital implant with no less than 4.2 mm diameter allowed by the anatomy. Lippincott Williams & Wilkins 2017-03 2016-12-21 /pmc/articles/PMC5367500/ /pubmed/28005657 http://dx.doi.org/10.1097/SCS.0000000000003305 Text en Copyright © 2016 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of Mutaz B. Habal, MD. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle Brief Clinical Studies
Xing, Zhang
Chen, Ling Song
Peng, Wei
Chen, Ling Jian
Influence of Orbital Implant Length and Diameter on Stress Distribution: A Finite Element Analysis
title Influence of Orbital Implant Length and Diameter on Stress Distribution: A Finite Element Analysis
title_full Influence of Orbital Implant Length and Diameter on Stress Distribution: A Finite Element Analysis
title_fullStr Influence of Orbital Implant Length and Diameter on Stress Distribution: A Finite Element Analysis
title_full_unstemmed Influence of Orbital Implant Length and Diameter on Stress Distribution: A Finite Element Analysis
title_short Influence of Orbital Implant Length and Diameter on Stress Distribution: A Finite Element Analysis
title_sort influence of orbital implant length and diameter on stress distribution: a finite element analysis
topic Brief Clinical Studies
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5367500/
https://www.ncbi.nlm.nih.gov/pubmed/28005657
http://dx.doi.org/10.1097/SCS.0000000000003305
work_keys_str_mv AT xingzhang influenceoforbitalimplantlengthanddiameteronstressdistributionafiniteelementanalysis
AT chenlingsong influenceoforbitalimplantlengthanddiameteronstressdistributionafiniteelementanalysis
AT pengwei influenceoforbitalimplantlengthanddiameteronstressdistributionafiniteelementanalysis
AT chenlingjian influenceoforbitalimplantlengthanddiameteronstressdistributionafiniteelementanalysis