Cargando…
Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries
We report the first use of swept-source microscope-integrated optical coherence tomography (SS-MIOCT) capable of live four-dimensional (4D) (three-dimensional across time) imaging intraoperatively to directly visualize tube shunt placement and trabeculectomy surgeries in two patients with severe ope...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5369296/ https://www.ncbi.nlm.nih.gov/pubmed/28300743 http://dx.doi.org/10.4103/ijo.IJO_412_16 |
_version_ | 1782518101330362368 |
---|---|
author | Pasricha, Neel Dave Bhullar, Paramjit Kaur Shieh, Christine Viehland, Christian Carrasco-Zevallos, Oscar Mijail Keller, Brenton Izatt, Joseph Adam Toth, Cynthia Ann Challa, Pratap Kuo, Anthony Nanlin |
author_facet | Pasricha, Neel Dave Bhullar, Paramjit Kaur Shieh, Christine Viehland, Christian Carrasco-Zevallos, Oscar Mijail Keller, Brenton Izatt, Joseph Adam Toth, Cynthia Ann Challa, Pratap Kuo, Anthony Nanlin |
author_sort | Pasricha, Neel Dave |
collection | PubMed |
description | We report the first use of swept-source microscope-integrated optical coherence tomography (SS-MIOCT) capable of live four-dimensional (4D) (three-dimensional across time) imaging intraoperatively to directly visualize tube shunt placement and trabeculectomy surgeries in two patients with severe open-angle glaucoma and elevated intraocular pressure (IOP) that was not adequately managed by medical intervention or prior surgery. We performed tube shunt placement and trabeculectomy surgery and used SS-MIOCT to visualize and record surgical steps that benefitted from the enhanced visualization. In the case of tube shunt placement, SS-MIOCT successfully visualized the scleral tunneling, tube shunt positioning in the anterior chamber, and tube shunt suturing. For the trabeculectomy, SS-MIOCT successfully visualized the scleral flap creation, sclerotomy, and iridectomy. Postoperatively, both patients did well, with IOPs decreasing to the target goal. We found the benefit of SS-MIOCT was greatest in surgical steps requiring depth-based assessments. This technology has the potential to improve clinical outcomes. |
format | Online Article Text |
id | pubmed-5369296 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-53692962017-04-11 Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries Pasricha, Neel Dave Bhullar, Paramjit Kaur Shieh, Christine Viehland, Christian Carrasco-Zevallos, Oscar Mijail Keller, Brenton Izatt, Joseph Adam Toth, Cynthia Ann Challa, Pratap Kuo, Anthony Nanlin Indian J Ophthalmol Brief Communications We report the first use of swept-source microscope-integrated optical coherence tomography (SS-MIOCT) capable of live four-dimensional (4D) (three-dimensional across time) imaging intraoperatively to directly visualize tube shunt placement and trabeculectomy surgeries in two patients with severe open-angle glaucoma and elevated intraocular pressure (IOP) that was not adequately managed by medical intervention or prior surgery. We performed tube shunt placement and trabeculectomy surgery and used SS-MIOCT to visualize and record surgical steps that benefitted from the enhanced visualization. In the case of tube shunt placement, SS-MIOCT successfully visualized the scleral tunneling, tube shunt positioning in the anterior chamber, and tube shunt suturing. For the trabeculectomy, SS-MIOCT successfully visualized the scleral flap creation, sclerotomy, and iridectomy. Postoperatively, both patients did well, with IOPs decreasing to the target goal. We found the benefit of SS-MIOCT was greatest in surgical steps requiring depth-based assessments. This technology has the potential to improve clinical outcomes. Medknow Publications & Media Pvt Ltd 2017-01 /pmc/articles/PMC5369296/ /pubmed/28300743 http://dx.doi.org/10.4103/ijo.IJO_412_16 Text en Copyright: © 2017 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Brief Communications Pasricha, Neel Dave Bhullar, Paramjit Kaur Shieh, Christine Viehland, Christian Carrasco-Zevallos, Oscar Mijail Keller, Brenton Izatt, Joseph Adam Toth, Cynthia Ann Challa, Pratap Kuo, Anthony Nanlin Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries |
title | Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries |
title_full | Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries |
title_fullStr | Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries |
title_full_unstemmed | Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries |
title_short | Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries |
title_sort | four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries |
topic | Brief Communications |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5369296/ https://www.ncbi.nlm.nih.gov/pubmed/28300743 http://dx.doi.org/10.4103/ijo.IJO_412_16 |
work_keys_str_mv | AT pasrichaneeldave fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries AT bhullarparamjitkaur fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries AT shiehchristine fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries AT viehlandchristian fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries AT carrascozevallososcarmijail fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries AT kellerbrenton fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries AT izattjosephadam fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries AT tothcynthiaann fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries AT challapratap fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries AT kuoanthonynanlin fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries |