Cargando…

Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries

We report the first use of swept-source microscope-integrated optical coherence tomography (SS-MIOCT) capable of live four-dimensional (4D) (three-dimensional across time) imaging intraoperatively to directly visualize tube shunt placement and trabeculectomy surgeries in two patients with severe ope...

Descripción completa

Detalles Bibliográficos
Autores principales: Pasricha, Neel Dave, Bhullar, Paramjit Kaur, Shieh, Christine, Viehland, Christian, Carrasco-Zevallos, Oscar Mijail, Keller, Brenton, Izatt, Joseph Adam, Toth, Cynthia Ann, Challa, Pratap, Kuo, Anthony Nanlin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5369296/
https://www.ncbi.nlm.nih.gov/pubmed/28300743
http://dx.doi.org/10.4103/ijo.IJO_412_16
_version_ 1782518101330362368
author Pasricha, Neel Dave
Bhullar, Paramjit Kaur
Shieh, Christine
Viehland, Christian
Carrasco-Zevallos, Oscar Mijail
Keller, Brenton
Izatt, Joseph Adam
Toth, Cynthia Ann
Challa, Pratap
Kuo, Anthony Nanlin
author_facet Pasricha, Neel Dave
Bhullar, Paramjit Kaur
Shieh, Christine
Viehland, Christian
Carrasco-Zevallos, Oscar Mijail
Keller, Brenton
Izatt, Joseph Adam
Toth, Cynthia Ann
Challa, Pratap
Kuo, Anthony Nanlin
author_sort Pasricha, Neel Dave
collection PubMed
description We report the first use of swept-source microscope-integrated optical coherence tomography (SS-MIOCT) capable of live four-dimensional (4D) (three-dimensional across time) imaging intraoperatively to directly visualize tube shunt placement and trabeculectomy surgeries in two patients with severe open-angle glaucoma and elevated intraocular pressure (IOP) that was not adequately managed by medical intervention or prior surgery. We performed tube shunt placement and trabeculectomy surgery and used SS-MIOCT to visualize and record surgical steps that benefitted from the enhanced visualization. In the case of tube shunt placement, SS-MIOCT successfully visualized the scleral tunneling, tube shunt positioning in the anterior chamber, and tube shunt suturing. For the trabeculectomy, SS-MIOCT successfully visualized the scleral flap creation, sclerotomy, and iridectomy. Postoperatively, both patients did well, with IOPs decreasing to the target goal. We found the benefit of SS-MIOCT was greatest in surgical steps requiring depth-based assessments. This technology has the potential to improve clinical outcomes.
format Online
Article
Text
id pubmed-5369296
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-53692962017-04-11 Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries Pasricha, Neel Dave Bhullar, Paramjit Kaur Shieh, Christine Viehland, Christian Carrasco-Zevallos, Oscar Mijail Keller, Brenton Izatt, Joseph Adam Toth, Cynthia Ann Challa, Pratap Kuo, Anthony Nanlin Indian J Ophthalmol Brief Communications We report the first use of swept-source microscope-integrated optical coherence tomography (SS-MIOCT) capable of live four-dimensional (4D) (three-dimensional across time) imaging intraoperatively to directly visualize tube shunt placement and trabeculectomy surgeries in two patients with severe open-angle glaucoma and elevated intraocular pressure (IOP) that was not adequately managed by medical intervention or prior surgery. We performed tube shunt placement and trabeculectomy surgery and used SS-MIOCT to visualize and record surgical steps that benefitted from the enhanced visualization. In the case of tube shunt placement, SS-MIOCT successfully visualized the scleral tunneling, tube shunt positioning in the anterior chamber, and tube shunt suturing. For the trabeculectomy, SS-MIOCT successfully visualized the scleral flap creation, sclerotomy, and iridectomy. Postoperatively, both patients did well, with IOPs decreasing to the target goal. We found the benefit of SS-MIOCT was greatest in surgical steps requiring depth-based assessments. This technology has the potential to improve clinical outcomes. Medknow Publications & Media Pvt Ltd 2017-01 /pmc/articles/PMC5369296/ /pubmed/28300743 http://dx.doi.org/10.4103/ijo.IJO_412_16 Text en Copyright: © 2017 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Brief Communications
Pasricha, Neel Dave
Bhullar, Paramjit Kaur
Shieh, Christine
Viehland, Christian
Carrasco-Zevallos, Oscar Mijail
Keller, Brenton
Izatt, Joseph Adam
Toth, Cynthia Ann
Challa, Pratap
Kuo, Anthony Nanlin
Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries
title Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries
title_full Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries
title_fullStr Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries
title_full_unstemmed Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries
title_short Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries
title_sort four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries
topic Brief Communications
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5369296/
https://www.ncbi.nlm.nih.gov/pubmed/28300743
http://dx.doi.org/10.4103/ijo.IJO_412_16
work_keys_str_mv AT pasrichaneeldave fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries
AT bhullarparamjitkaur fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries
AT shiehchristine fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries
AT viehlandchristian fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries
AT carrascozevallososcarmijail fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries
AT kellerbrenton fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries
AT izattjosephadam fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries
AT tothcynthiaann fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries
AT challapratap fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries
AT kuoanthonynanlin fourdimensionalmicroscopeintegratedopticalcoherencetomographytoenhancevisualizationinglaucomasurgeries