Cargando…

A modified-simple technique of removing the lens cortex during cataract surgery

We describe here a surgical technique of removing the remaining cortex after phacoemulsification without performing the conventional irrigation/aspiration (I/A) procedure. In this technique, the remaining cortex attached to the posterior capsule was separated and dissected into several pieces by con...

Descripción completa

Detalles Bibliográficos
Autores principales: Han, Kyung Eun, Han, Se Hoon, Lim, Dongkwon, Shin, Min Chul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5369297/
https://www.ncbi.nlm.nih.gov/pubmed/28300744
http://dx.doi.org/10.4103/ijo.IJO_456_14
_version_ 1782518101568389120
author Han, Kyung Eun
Han, Se Hoon
Lim, Dongkwon
Shin, Min Chul
author_facet Han, Kyung Eun
Han, Se Hoon
Lim, Dongkwon
Shin, Min Chul
author_sort Han, Kyung Eun
collection PubMed
description We describe here a surgical technique of removing the remaining cortex after phacoemulsification without performing the conventional irrigation/aspiration (I/A) procedure. In this technique, the remaining cortex attached to the posterior capsule was separated and dissected into several pieces by continuous irrigation with balanced salt solution, which was supplied through a syringe attached to a bent, blunt-tip needle. Approximately, 10 s of manual irrigation separated most of the remaining cortex from the posterior capsule. Then, the capsular bag was inflated with an ophthalmic viscoelastic device (OVD), and this pushed the separated cortex toward the capsular fornix mechanically. An intraocular lens was inserted into the capsular bag, following which the remaining cortex and OVD were removed concomitantly using an automated I/A handpiece. This technique is a simple and easy maneuver to remove the cortex from all areas, including the subincisional area, and reduce the possibility of a posterior capsule tear.
format Online
Article
Text
id pubmed-5369297
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-53692972017-04-11 A modified-simple technique of removing the lens cortex during cataract surgery Han, Kyung Eun Han, Se Hoon Lim, Dongkwon Shin, Min Chul Indian J Ophthalmol Brief Communications We describe here a surgical technique of removing the remaining cortex after phacoemulsification without performing the conventional irrigation/aspiration (I/A) procedure. In this technique, the remaining cortex attached to the posterior capsule was separated and dissected into several pieces by continuous irrigation with balanced salt solution, which was supplied through a syringe attached to a bent, blunt-tip needle. Approximately, 10 s of manual irrigation separated most of the remaining cortex from the posterior capsule. Then, the capsular bag was inflated with an ophthalmic viscoelastic device (OVD), and this pushed the separated cortex toward the capsular fornix mechanically. An intraocular lens was inserted into the capsular bag, following which the remaining cortex and OVD were removed concomitantly using an automated I/A handpiece. This technique is a simple and easy maneuver to remove the cortex from all areas, including the subincisional area, and reduce the possibility of a posterior capsule tear. Medknow Publications & Media Pvt Ltd 2017-01 /pmc/articles/PMC5369297/ /pubmed/28300744 http://dx.doi.org/10.4103/ijo.IJO_456_14 Text en Copyright: © 2017 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Brief Communications
Han, Kyung Eun
Han, Se Hoon
Lim, Dongkwon
Shin, Min Chul
A modified-simple technique of removing the lens cortex during cataract surgery
title A modified-simple technique of removing the lens cortex during cataract surgery
title_full A modified-simple technique of removing the lens cortex during cataract surgery
title_fullStr A modified-simple technique of removing the lens cortex during cataract surgery
title_full_unstemmed A modified-simple technique of removing the lens cortex during cataract surgery
title_short A modified-simple technique of removing the lens cortex during cataract surgery
title_sort modified-simple technique of removing the lens cortex during cataract surgery
topic Brief Communications
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5369297/
https://www.ncbi.nlm.nih.gov/pubmed/28300744
http://dx.doi.org/10.4103/ijo.IJO_456_14
work_keys_str_mv AT hankyungeun amodifiedsimpletechniqueofremovingthelenscortexduringcataractsurgery
AT hansehoon amodifiedsimpletechniqueofremovingthelenscortexduringcataractsurgery
AT limdongkwon amodifiedsimpletechniqueofremovingthelenscortexduringcataractsurgery
AT shinminchul amodifiedsimpletechniqueofremovingthelenscortexduringcataractsurgery
AT hankyungeun modifiedsimpletechniqueofremovingthelenscortexduringcataractsurgery
AT hansehoon modifiedsimpletechniqueofremovingthelenscortexduringcataractsurgery
AT limdongkwon modifiedsimpletechniqueofremovingthelenscortexduringcataractsurgery
AT shinminchul modifiedsimpletechniqueofremovingthelenscortexduringcataractsurgery