A modified-simple technique of removing the lens cortex during cataract surgery
We describe here a surgical technique of removing the remaining cortex after phacoemulsification without performing the conventional irrigation/aspiration (I/A) procedure. In this technique, the remaining cortex attached to the posterior capsule was separated and dissected into several pieces by con...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5369297/ https://www.ncbi.nlm.nih.gov/pubmed/28300744 http://dx.doi.org/10.4103/ijo.IJO_456_14 |
_version_ | 1782518101568389120 |
---|---|
author | Han, Kyung Eun Han, Se Hoon Lim, Dongkwon Shin, Min Chul |
author_facet | Han, Kyung Eun Han, Se Hoon Lim, Dongkwon Shin, Min Chul |
author_sort | Han, Kyung Eun |
collection | PubMed |
description | We describe here a surgical technique of removing the remaining cortex after phacoemulsification without performing the conventional irrigation/aspiration (I/A) procedure. In this technique, the remaining cortex attached to the posterior capsule was separated and dissected into several pieces by continuous irrigation with balanced salt solution, which was supplied through a syringe attached to a bent, blunt-tip needle. Approximately, 10 s of manual irrigation separated most of the remaining cortex from the posterior capsule. Then, the capsular bag was inflated with an ophthalmic viscoelastic device (OVD), and this pushed the separated cortex toward the capsular fornix mechanically. An intraocular lens was inserted into the capsular bag, following which the remaining cortex and OVD were removed concomitantly using an automated I/A handpiece. This technique is a simple and easy maneuver to remove the cortex from all areas, including the subincisional area, and reduce the possibility of a posterior capsule tear. |
format | Online Article Text |
id | pubmed-5369297 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-53692972017-04-11 A modified-simple technique of removing the lens cortex during cataract surgery Han, Kyung Eun Han, Se Hoon Lim, Dongkwon Shin, Min Chul Indian J Ophthalmol Brief Communications We describe here a surgical technique of removing the remaining cortex after phacoemulsification without performing the conventional irrigation/aspiration (I/A) procedure. In this technique, the remaining cortex attached to the posterior capsule was separated and dissected into several pieces by continuous irrigation with balanced salt solution, which was supplied through a syringe attached to a bent, blunt-tip needle. Approximately, 10 s of manual irrigation separated most of the remaining cortex from the posterior capsule. Then, the capsular bag was inflated with an ophthalmic viscoelastic device (OVD), and this pushed the separated cortex toward the capsular fornix mechanically. An intraocular lens was inserted into the capsular bag, following which the remaining cortex and OVD were removed concomitantly using an automated I/A handpiece. This technique is a simple and easy maneuver to remove the cortex from all areas, including the subincisional area, and reduce the possibility of a posterior capsule tear. Medknow Publications & Media Pvt Ltd 2017-01 /pmc/articles/PMC5369297/ /pubmed/28300744 http://dx.doi.org/10.4103/ijo.IJO_456_14 Text en Copyright: © 2017 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Brief Communications Han, Kyung Eun Han, Se Hoon Lim, Dongkwon Shin, Min Chul A modified-simple technique of removing the lens cortex during cataract surgery |
title | A modified-simple technique of removing the lens cortex during cataract surgery |
title_full | A modified-simple technique of removing the lens cortex during cataract surgery |
title_fullStr | A modified-simple technique of removing the lens cortex during cataract surgery |
title_full_unstemmed | A modified-simple technique of removing the lens cortex during cataract surgery |
title_short | A modified-simple technique of removing the lens cortex during cataract surgery |
title_sort | modified-simple technique of removing the lens cortex during cataract surgery |
topic | Brief Communications |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5369297/ https://www.ncbi.nlm.nih.gov/pubmed/28300744 http://dx.doi.org/10.4103/ijo.IJO_456_14 |
work_keys_str_mv | AT hankyungeun amodifiedsimpletechniqueofremovingthelenscortexduringcataractsurgery AT hansehoon amodifiedsimpletechniqueofremovingthelenscortexduringcataractsurgery AT limdongkwon amodifiedsimpletechniqueofremovingthelenscortexduringcataractsurgery AT shinminchul amodifiedsimpletechniqueofremovingthelenscortexduringcataractsurgery AT hankyungeun modifiedsimpletechniqueofremovingthelenscortexduringcataractsurgery AT hansehoon modifiedsimpletechniqueofremovingthelenscortexduringcataractsurgery AT limdongkwon modifiedsimpletechniqueofremovingthelenscortexduringcataractsurgery AT shinminchul modifiedsimpletechniqueofremovingthelenscortexduringcataractsurgery |