Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography

PURPOSE: This study was performed to investigate the intra- and inter-observer variability in linear measurements with axial images obtained by PreXion (PreXion Inc., San Mateo, USA) and i-CAT (Imaging Sciences International, Xoran Technologies Inc., Hatfield, USA) CBCT scanners, with different voxe...

Descripción completa

Detalles Bibliográficos
Autores principales: da Silva, Nathália Cristine, Barriviera, Maurício, Junqueira, José Luiz Cintra, Panzarella, Francine Kühl, Raitz, Ricardo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Oral and Maxillofacial Radiology 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5370249/
https://www.ncbi.nlm.nih.gov/pubmed/28361024
http://dx.doi.org/10.5624/isd.2017.47.1.11
_version_ 1782518204659138560
author da Silva, Nathália Cristine
Barriviera, Maurício
Junqueira, José Luiz Cintra
Panzarella, Francine Kühl
Raitz, Ricardo
author_facet da Silva, Nathália Cristine
Barriviera, Maurício
Junqueira, José Luiz Cintra
Panzarella, Francine Kühl
Raitz, Ricardo
author_sort da Silva, Nathália Cristine
collection PubMed
description PURPOSE: This study was performed to investigate the intra- and inter-observer variability in linear measurements with axial images obtained by PreXion (PreXion Inc., San Mateo, USA) and i-CAT (Imaging Sciences International, Xoran Technologies Inc., Hatfield, USA) CBCT scanners, with different voxel sizes. MATERIALS AND METHODS: A cylindrical object made from nylon with radiopaque markers (phantom) was scanned by i-CAT and PreXion 3D devices. For each axial image, measurements were taken twice in the horizontal (distance A-B) and vertical (distance C-D) directions, randomly, with a one-week interval between measurements, by four oral radiologists with five years or more experience in the use of these measuring tools. RESULTS: All of the obtained linear measurements had lower values than those of the phantom. The statistical analysis showed high intra- and inter-observer reliability (p=0.297). Compared to the real measurements, the measurements obtained using the i-CAT device and PreXion tomography, on average, revealed absolute errors ranging from 0.22 to 0.59 mm and from 0.23 to 0.63 mm, respectively. CONCLUSION: It can be concluded that both scanners are accurate, although the linear measurements are underestimations, with no significant differences between the evaluators.
format Online
Article
Text
id pubmed-5370249
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Korean Academy of Oral and Maxillofacial Radiology
record_format MEDLINE/PubMed
spelling pubmed-53702492017-03-30 Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography da Silva, Nathália Cristine Barriviera, Maurício Junqueira, José Luiz Cintra Panzarella, Francine Kühl Raitz, Ricardo Imaging Sci Dent Original Article PURPOSE: This study was performed to investigate the intra- and inter-observer variability in linear measurements with axial images obtained by PreXion (PreXion Inc., San Mateo, USA) and i-CAT (Imaging Sciences International, Xoran Technologies Inc., Hatfield, USA) CBCT scanners, with different voxel sizes. MATERIALS AND METHODS: A cylindrical object made from nylon with radiopaque markers (phantom) was scanned by i-CAT and PreXion 3D devices. For each axial image, measurements were taken twice in the horizontal (distance A-B) and vertical (distance C-D) directions, randomly, with a one-week interval between measurements, by four oral radiologists with five years or more experience in the use of these measuring tools. RESULTS: All of the obtained linear measurements had lower values than those of the phantom. The statistical analysis showed high intra- and inter-observer reliability (p=0.297). Compared to the real measurements, the measurements obtained using the i-CAT device and PreXion tomography, on average, revealed absolute errors ranging from 0.22 to 0.59 mm and from 0.23 to 0.63 mm, respectively. CONCLUSION: It can be concluded that both scanners are accurate, although the linear measurements are underestimations, with no significant differences between the evaluators. Korean Academy of Oral and Maxillofacial Radiology 2017-03 2017-03-21 /pmc/articles/PMC5370249/ /pubmed/28361024 http://dx.doi.org/10.5624/isd.2017.47.1.11 Text en Copyright © 2017 by Korean Academy of Oral and Maxillofacial Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
da Silva, Nathália Cristine
Barriviera, Maurício
Junqueira, José Luiz Cintra
Panzarella, Francine Kühl
Raitz, Ricardo
Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography
title Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography
title_full Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography
title_fullStr Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography
title_full_unstemmed Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography
title_short Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography
title_sort intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5370249/
https://www.ncbi.nlm.nih.gov/pubmed/28361024
http://dx.doi.org/10.5624/isd.2017.47.1.11
work_keys_str_mv AT dasilvanathaliacristine intraobserverandinterobserverreproducibilityinlinearmeasurementsonaxialimagesobtainedbyconebeamcomputedtomography
AT barrivieramauricio intraobserverandinterobserverreproducibilityinlinearmeasurementsonaxialimagesobtainedbyconebeamcomputedtomography
AT junqueirajoseluizcintra intraobserverandinterobserverreproducibilityinlinearmeasurementsonaxialimagesobtainedbyconebeamcomputedtomography
AT panzarellafrancinekuhl intraobserverandinterobserverreproducibilityinlinearmeasurementsonaxialimagesobtainedbyconebeamcomputedtomography
AT raitzricardo intraobserverandinterobserverreproducibilityinlinearmeasurementsonaxialimagesobtainedbyconebeamcomputedtomography