Cargando…
Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography
PURPOSE: This study was performed to investigate the intra- and inter-observer variability in linear measurements with axial images obtained by PreXion (PreXion Inc., San Mateo, USA) and i-CAT (Imaging Sciences International, Xoran Technologies Inc., Hatfield, USA) CBCT scanners, with different voxe...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Oral and Maxillofacial Radiology
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5370249/ https://www.ncbi.nlm.nih.gov/pubmed/28361024 http://dx.doi.org/10.5624/isd.2017.47.1.11 |
_version_ | 1782518204659138560 |
---|---|
author | da Silva, Nathália Cristine Barriviera, Maurício Junqueira, José Luiz Cintra Panzarella, Francine Kühl Raitz, Ricardo |
author_facet | da Silva, Nathália Cristine Barriviera, Maurício Junqueira, José Luiz Cintra Panzarella, Francine Kühl Raitz, Ricardo |
author_sort | da Silva, Nathália Cristine |
collection | PubMed |
description | PURPOSE: This study was performed to investigate the intra- and inter-observer variability in linear measurements with axial images obtained by PreXion (PreXion Inc., San Mateo, USA) and i-CAT (Imaging Sciences International, Xoran Technologies Inc., Hatfield, USA) CBCT scanners, with different voxel sizes. MATERIALS AND METHODS: A cylindrical object made from nylon with radiopaque markers (phantom) was scanned by i-CAT and PreXion 3D devices. For each axial image, measurements were taken twice in the horizontal (distance A-B) and vertical (distance C-D) directions, randomly, with a one-week interval between measurements, by four oral radiologists with five years or more experience in the use of these measuring tools. RESULTS: All of the obtained linear measurements had lower values than those of the phantom. The statistical analysis showed high intra- and inter-observer reliability (p=0.297). Compared to the real measurements, the measurements obtained using the i-CAT device and PreXion tomography, on average, revealed absolute errors ranging from 0.22 to 0.59 mm and from 0.23 to 0.63 mm, respectively. CONCLUSION: It can be concluded that both scanners are accurate, although the linear measurements are underestimations, with no significant differences between the evaluators. |
format | Online Article Text |
id | pubmed-5370249 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Korean Academy of Oral and Maxillofacial Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-53702492017-03-30 Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography da Silva, Nathália Cristine Barriviera, Maurício Junqueira, José Luiz Cintra Panzarella, Francine Kühl Raitz, Ricardo Imaging Sci Dent Original Article PURPOSE: This study was performed to investigate the intra- and inter-observer variability in linear measurements with axial images obtained by PreXion (PreXion Inc., San Mateo, USA) and i-CAT (Imaging Sciences International, Xoran Technologies Inc., Hatfield, USA) CBCT scanners, with different voxel sizes. MATERIALS AND METHODS: A cylindrical object made from nylon with radiopaque markers (phantom) was scanned by i-CAT and PreXion 3D devices. For each axial image, measurements were taken twice in the horizontal (distance A-B) and vertical (distance C-D) directions, randomly, with a one-week interval between measurements, by four oral radiologists with five years or more experience in the use of these measuring tools. RESULTS: All of the obtained linear measurements had lower values than those of the phantom. The statistical analysis showed high intra- and inter-observer reliability (p=0.297). Compared to the real measurements, the measurements obtained using the i-CAT device and PreXion tomography, on average, revealed absolute errors ranging from 0.22 to 0.59 mm and from 0.23 to 0.63 mm, respectively. CONCLUSION: It can be concluded that both scanners are accurate, although the linear measurements are underestimations, with no significant differences between the evaluators. Korean Academy of Oral and Maxillofacial Radiology 2017-03 2017-03-21 /pmc/articles/PMC5370249/ /pubmed/28361024 http://dx.doi.org/10.5624/isd.2017.47.1.11 Text en Copyright © 2017 by Korean Academy of Oral and Maxillofacial Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article da Silva, Nathália Cristine Barriviera, Maurício Junqueira, José Luiz Cintra Panzarella, Francine Kühl Raitz, Ricardo Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography |
title | Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography |
title_full | Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography |
title_fullStr | Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography |
title_full_unstemmed | Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography |
title_short | Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography |
title_sort | intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5370249/ https://www.ncbi.nlm.nih.gov/pubmed/28361024 http://dx.doi.org/10.5624/isd.2017.47.1.11 |
work_keys_str_mv | AT dasilvanathaliacristine intraobserverandinterobserverreproducibilityinlinearmeasurementsonaxialimagesobtainedbyconebeamcomputedtomography AT barrivieramauricio intraobserverandinterobserverreproducibilityinlinearmeasurementsonaxialimagesobtainedbyconebeamcomputedtomography AT junqueirajoseluizcintra intraobserverandinterobserverreproducibilityinlinearmeasurementsonaxialimagesobtainedbyconebeamcomputedtomography AT panzarellafrancinekuhl intraobserverandinterobserverreproducibilityinlinearmeasurementsonaxialimagesobtainedbyconebeamcomputedtomography AT raitzricardo intraobserverandinterobserverreproducibilityinlinearmeasurementsonaxialimagesobtainedbyconebeamcomputedtomography |