Cargando…
Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques
PURPOSE: The aim of this study was to compare the diagnostic accuracy of previously trained endodontists in the detection of artificially created periapical lesions using cone-beam computed tomography (CBCT) and digital periapical radiography (DPR). MATERIALS AND METHODS: An ex vivo model using dry...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Oral and Maxillofacial Radiology
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5370254/ https://www.ncbi.nlm.nih.gov/pubmed/28361026 http://dx.doi.org/10.5624/isd.2017.47.1.25 |
_version_ | 1782518205790552064 |
---|---|
author | Campello, Andrea Fagundes Gonçalves, Lucio Souza Guedes, Fábio Ribeiro Marques, Fábio Vidal |
author_facet | Campello, Andrea Fagundes Gonçalves, Lucio Souza Guedes, Fábio Ribeiro Marques, Fábio Vidal |
author_sort | Campello, Andrea Fagundes |
collection | PubMed |
description | PURPOSE: The aim of this study was to compare the diagnostic accuracy of previously trained endodontists in the detection of artificially created periapical lesions using cone-beam computed tomography (CBCT) and digital periapical radiography (DPR). MATERIALS AND METHODS: An ex vivo model using dry skulls was used, in which simulated apical lesions were created and then progressively enlarged using #1/2, #2, #4, and #6 round burs. A total of 11 teeth were included in the study, and 110 images were obtained with CBCT and with an intraoral digital periapical radiographic sensor (Instrumentarium dental, Tuusula, Finland) initially and after each bur was used. Specificity and sensitivity were calculated. All images were evaluated by 10 previously trained, certified endodontists. Agreement was calculated using the kappa coefficient. The accuracy of each method in detecting apical lesions was calculated using the chi-square test. RESULTS: The kappa coefficient between examiners showed low agreement (range, 0.17-0.64). No statistical difference was found between CBCT and DPR in teeth without apical lesions (P=.15). The accuracy for CBCT was significantly higher than for DPR in all corresponding simulated lesions (P<.001). The correct diagnostic rate for CBCT ranged between 56.9% and 73.6%. The greatest difference between CBCT and DPR was seen in the maxillary teeth (CBCT, 71.4%; DPR, 28.6%; P<.01) and multi-rooted teeth (CBCT, 83.3%; DPR, 33.3%; P<.01). CONCLUSION: CBCT allowed higher accuracy than DPR in detecting simulated lesions for all simulated lesions tested. Endodontists need to be properly trained in interpreting CBCT scans to achieve higher diagnostic accuracy. |
format | Online Article Text |
id | pubmed-5370254 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Korean Academy of Oral and Maxillofacial Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-53702542017-03-30 Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques Campello, Andrea Fagundes Gonçalves, Lucio Souza Guedes, Fábio Ribeiro Marques, Fábio Vidal Imaging Sci Dent Original Article PURPOSE: The aim of this study was to compare the diagnostic accuracy of previously trained endodontists in the detection of artificially created periapical lesions using cone-beam computed tomography (CBCT) and digital periapical radiography (DPR). MATERIALS AND METHODS: An ex vivo model using dry skulls was used, in which simulated apical lesions were created and then progressively enlarged using #1/2, #2, #4, and #6 round burs. A total of 11 teeth were included in the study, and 110 images were obtained with CBCT and with an intraoral digital periapical radiographic sensor (Instrumentarium dental, Tuusula, Finland) initially and after each bur was used. Specificity and sensitivity were calculated. All images were evaluated by 10 previously trained, certified endodontists. Agreement was calculated using the kappa coefficient. The accuracy of each method in detecting apical lesions was calculated using the chi-square test. RESULTS: The kappa coefficient between examiners showed low agreement (range, 0.17-0.64). No statistical difference was found between CBCT and DPR in teeth without apical lesions (P=.15). The accuracy for CBCT was significantly higher than for DPR in all corresponding simulated lesions (P<.001). The correct diagnostic rate for CBCT ranged between 56.9% and 73.6%. The greatest difference between CBCT and DPR was seen in the maxillary teeth (CBCT, 71.4%; DPR, 28.6%; P<.01) and multi-rooted teeth (CBCT, 83.3%; DPR, 33.3%; P<.01). CONCLUSION: CBCT allowed higher accuracy than DPR in detecting simulated lesions for all simulated lesions tested. Endodontists need to be properly trained in interpreting CBCT scans to achieve higher diagnostic accuracy. Korean Academy of Oral and Maxillofacial Radiology 2017-03 2017-03-21 /pmc/articles/PMC5370254/ /pubmed/28361026 http://dx.doi.org/10.5624/isd.2017.47.1.25 Text en Copyright © 2017 by Korean Academy of Oral and Maxillofacial Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Campello, Andrea Fagundes Gonçalves, Lucio Souza Guedes, Fábio Ribeiro Marques, Fábio Vidal Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques |
title | Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques |
title_full | Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques |
title_fullStr | Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques |
title_full_unstemmed | Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques |
title_short | Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques |
title_sort | cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: a pilot study of the diagnostic accuracy of endodontists using both techniques |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5370254/ https://www.ncbi.nlm.nih.gov/pubmed/28361026 http://dx.doi.org/10.5624/isd.2017.47.1.25 |
work_keys_str_mv | AT campelloandreafagundes conebeamcomputedtomographyversusdigitalperiapicalradiographyinthedetectionofartificiallycreatedperiapicallesionsapilotstudyofthediagnosticaccuracyofendodontistsusingbothtechniques AT goncalvesluciosouza conebeamcomputedtomographyversusdigitalperiapicalradiographyinthedetectionofartificiallycreatedperiapicallesionsapilotstudyofthediagnosticaccuracyofendodontistsusingbothtechniques AT guedesfabioribeiro conebeamcomputedtomographyversusdigitalperiapicalradiographyinthedetectionofartificiallycreatedperiapicallesionsapilotstudyofthediagnosticaccuracyofendodontistsusingbothtechniques AT marquesfabiovidal conebeamcomputedtomographyversusdigitalperiapicalradiographyinthedetectionofartificiallycreatedperiapicallesionsapilotstudyofthediagnosticaccuracyofendodontistsusingbothtechniques |