Cargando…

A novel system for continuous, real-time monitoring of heart motion signals

BACKGROUND: Understanding cardiac mechanics is important for developing cardiac therapies. Current modalities for assessing cardiac mechanics sample patient’s heart at specific heart rate, contractility, preload, and afterload. The objective of this study was to test the feasibility of a novel syste...

Descripción completa

Detalles Bibliográficos
Autores principales: Dori, Guy, Schliamser, Jorge E., Lichtenstein, Oscar, Anshelevich, Ilia, Flugelman, Moshe Y.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5371206/
https://www.ncbi.nlm.nih.gov/pubmed/28356163
http://dx.doi.org/10.1186/s40001-017-0252-2
_version_ 1782518373467291648
author Dori, Guy
Schliamser, Jorge E.
Lichtenstein, Oscar
Anshelevich, Ilia
Flugelman, Moshe Y.
author_facet Dori, Guy
Schliamser, Jorge E.
Lichtenstein, Oscar
Anshelevich, Ilia
Flugelman, Moshe Y.
author_sort Dori, Guy
collection PubMed
description BACKGROUND: Understanding cardiac mechanics is important for developing cardiac therapies. Current modalities for assessing cardiac mechanics sample patient’s heart at specific heart rate, contractility, preload, and afterload. The objective of this study was to test the feasibility of a novel system composed of intra-cardiac leads equipped with an inertial module chip (3D accelerometers and 3D gyroscopes) in monitoring continuous heart motion. METHODS: In this descriptive study, four healthy pigs were anesthetized and instrumented with motion-sensitive intra-cardiac leads; the temporal correlation between signals from motion sensors and tissue Doppler from the chest wall were studied; changes in real-time heart accelerations (ACC) and angular velocity (ANGV) were reported as percentages of change from baseline. RESULTS: Heart motion signals were sensed continuously from the right ventricular apex (RVa) and coronary sinus (CS). Volume expansion did not produce significant changes in the ACC and ANGV signals. Increasing heart rate increased the peak systolic ACC signal recorded from RVa and CS by 94 and 76%, respectively, and increased both peak systolic (61% RVa and 27% CS) and diastolic ANGV (200% CS vs. 31% RVa). Epinephrine administration increased peak systolic ACC signals at both sites (246% RVa; 331% CS). Peak systolic and diastolic ANGV increased in response to epinephrine (systolic: 198% RVa and 175% CS; diastolic: 723% CS and 89% RVa) (p = 0.125 for all changes expressed in percent). Temporal correlation between the ANGV signal and tissue Doppler signal was detected throughout all interventions. CONCLUSIONS: A novel system for continuously monitoring heart motion signals from within the heart was presented. Heart motion signals in response to physiologic manipulations were characterized.
format Online
Article
Text
id pubmed-5371206
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-53712062017-03-30 A novel system for continuous, real-time monitoring of heart motion signals Dori, Guy Schliamser, Jorge E. Lichtenstein, Oscar Anshelevich, Ilia Flugelman, Moshe Y. Eur J Med Res Research BACKGROUND: Understanding cardiac mechanics is important for developing cardiac therapies. Current modalities for assessing cardiac mechanics sample patient’s heart at specific heart rate, contractility, preload, and afterload. The objective of this study was to test the feasibility of a novel system composed of intra-cardiac leads equipped with an inertial module chip (3D accelerometers and 3D gyroscopes) in monitoring continuous heart motion. METHODS: In this descriptive study, four healthy pigs were anesthetized and instrumented with motion-sensitive intra-cardiac leads; the temporal correlation between signals from motion sensors and tissue Doppler from the chest wall were studied; changes in real-time heart accelerations (ACC) and angular velocity (ANGV) were reported as percentages of change from baseline. RESULTS: Heart motion signals were sensed continuously from the right ventricular apex (RVa) and coronary sinus (CS). Volume expansion did not produce significant changes in the ACC and ANGV signals. Increasing heart rate increased the peak systolic ACC signal recorded from RVa and CS by 94 and 76%, respectively, and increased both peak systolic (61% RVa and 27% CS) and diastolic ANGV (200% CS vs. 31% RVa). Epinephrine administration increased peak systolic ACC signals at both sites (246% RVa; 331% CS). Peak systolic and diastolic ANGV increased in response to epinephrine (systolic: 198% RVa and 175% CS; diastolic: 723% CS and 89% RVa) (p = 0.125 for all changes expressed in percent). Temporal correlation between the ANGV signal and tissue Doppler signal was detected throughout all interventions. CONCLUSIONS: A novel system for continuously monitoring heart motion signals from within the heart was presented. Heart motion signals in response to physiologic manipulations were characterized. BioMed Central 2017-03-29 /pmc/articles/PMC5371206/ /pubmed/28356163 http://dx.doi.org/10.1186/s40001-017-0252-2 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Dori, Guy
Schliamser, Jorge E.
Lichtenstein, Oscar
Anshelevich, Ilia
Flugelman, Moshe Y.
A novel system for continuous, real-time monitoring of heart motion signals
title A novel system for continuous, real-time monitoring of heart motion signals
title_full A novel system for continuous, real-time monitoring of heart motion signals
title_fullStr A novel system for continuous, real-time monitoring of heart motion signals
title_full_unstemmed A novel system for continuous, real-time monitoring of heart motion signals
title_short A novel system for continuous, real-time monitoring of heart motion signals
title_sort novel system for continuous, real-time monitoring of heart motion signals
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5371206/
https://www.ncbi.nlm.nih.gov/pubmed/28356163
http://dx.doi.org/10.1186/s40001-017-0252-2
work_keys_str_mv AT doriguy anovelsystemforcontinuousrealtimemonitoringofheartmotionsignals
AT schliamserjorgee anovelsystemforcontinuousrealtimemonitoringofheartmotionsignals
AT lichtensteinoscar anovelsystemforcontinuousrealtimemonitoringofheartmotionsignals
AT anshelevichilia anovelsystemforcontinuousrealtimemonitoringofheartmotionsignals
AT flugelmanmoshey anovelsystemforcontinuousrealtimemonitoringofheartmotionsignals
AT doriguy novelsystemforcontinuousrealtimemonitoringofheartmotionsignals
AT schliamserjorgee novelsystemforcontinuousrealtimemonitoringofheartmotionsignals
AT lichtensteinoscar novelsystemforcontinuousrealtimemonitoringofheartmotionsignals
AT anshelevichilia novelsystemforcontinuousrealtimemonitoringofheartmotionsignals
AT flugelmanmoshey novelsystemforcontinuousrealtimemonitoringofheartmotionsignals